Pfeiffer Helium Leak Detector HLT 570, 230 V, 50 HzvPTL02110 - Rugged, dependable helium leak detector, absolutely oil-free
- For a mains voltage of 230 V, 50 Hz
- With 2 m3/h diaphragm pump
- Very easy operation to achieve precise measuring results
- Wireless remote control optional, distance up to 100 m as well as data logging to USB stick
- Durable and industry-tested mass spectrometer
- Integrated test leak
- Bypass option for large test items
- For sniffer and vacuum leak detection
- Simple maintenance - low cost of ownership
Technical Data | Ambient temperature | 10-35 °C | | Cold start to ready | 3 min | | Detectable gases | 4He, 3He, H2 | | Flange (in) | DN 25 ISO-KF | | Inlet pressure max. | 25 mbar | | Input: Analog | ActiveLine vacuum transmitter | | Input: Digital | Start/Stop, Vent, Cero, Calibration, Bypass detection | | Interface | RS-232-C, RS-485 | | Leak rate display | 10-12 - 1 mbar l/s | | OuTPU t: Analog | Leakage rate signal 2 x 0-10 V, lin/log | | OuTPU t: Digital | Ready to start, Ready to measure, Leak, Error, Bypass valve, Calibration acknowledge | | Power consumption | 300 VA | | Pumping speed for He | 2.5 l/s | | Pumping time to ready: 0.5 l test volume | no | | Pumping time to ready: 0.5 l test volume | 1 s | | Pumping time to ready: 100 l test volume | no | | Pumping time to ready: 100 l test volume | 1300 s | | Pumping time to ready: 10 l test volume | no | | Pumping time to ready: 10 l test volume | 125 s | | Relay: Switching capacity | 2 x 230 V AC | | Relay: Switching current | 3 A | | Response time | 0.5 s | | Roughing pump | no | | Roughing pump | Diaphragm pump 2 m3/h | Smallest detectable leak rate for He (according AVS 2.1) | < 5·10-12 mbar l/s | | Sniffer probe, detectable leak rate | < 5·10-8 mbar l/s | | Supply | no | | Supply | 230 V, 50 Hz | | Test method | Vacuum and sniffing leak detection | | Weight | 44 kg | Helium Leak Detector – The clever and modular Solution. Simple Operation. Top Performance. With its modular design and it's new wireless remote control RC 500 WL, the SmartTest offers the perfect solution for vacuum leak detection. Fast, reliable results, lowest detectable leak rates and short recovery time are what characterize the SmartTest and make it such a powerful and dependable product. Utmost sensitivity in identifying even the smallest leaks. Quantification of the leaks. Outstanding reproducibility of the measurement. Helium test gas is non-toxic and non-flammable. Short measurement times
PN06056 For more information, please visit this products webpage. |