phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
Main Categories

- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Category of products: Pfeiffer Vacuum
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Found 3 products
Item#: PN23759 Mfr Part#: PSA30105 / PS A30 105 B Manufacturer: Pfeiffer Vacuum
Price upon request

Pfeiffer Basic Calibration System for Gauges, 110-230 V 50/60 Hz, PSA30105, PS A30 105

 

Pfeiffer Calibration System Basic Overview:


The calibration system consists of a turbo pumping station HiCube 80 Eco as main component and a mounted vacuum chamber on top, which is attached by the support on the butterfly valve and the turbo pump respectively on the housing. The calibration system can be switched on and off with the master switch. The display control unit takes ove the control and monitoring. 

The backing pump generates the necessary fore-vacuum for the turbo pump. On top of the vacuum chamber are depending on the unit model several flange connections with different nominal diameters for vacuum gauges. The are closed with blank flanges ex works. The centrally positioned GAV on the vacuum chamber is for central manual gas inlet regulation. The Pirani/Cold cathode transmitter on the vacuum chamber controls the calibration system. 

The vacuum chamber can be closed off from the turbo pump with the manual butterfly valve. The T handle indicates the valve position. The electronic drive unit is supplied with power by the power supply pack and is an inherent part of the turbo pump. It is for inducement, monitoring and control of the turbo pump. The turbo pump is additionally equipped with a venting valve, which vents the turbo pump automatically in case of deactivation or a power cut-off. The HiPace air cooling unit cools the turbo pump during operation.

In view of increasingly stringent quality assurance requirements where the accuracy and reproducibility of the vacuum measured during production and service work is essential as well as the vacuum gauges required for this, the demand for calibration systems is steadily increasing in the market place. In critical processes, the accuracy of vacuum measurements is important for process stability, quality and for monitoring these processes. The pharmaceutical industry requires precise vacuum measurements for safeguarding its high quality product. This is the case particularly in freeze drying expensive drugs. For this reason, regular calibration of vacuum gauges is required. This also applies for final vacuum measurements on vacuum systems in service applications in line with factory or international standards.

To cover the majority of applications, Pfeiffer Vacuum has developed two calibration systems - Basic and Pro system.

 

Pfeiffer Calibration System Basic Structure:


Pfeiffer Calibration System Basic Structure, PSA30105, PS A30 105

 

Pfeiffer Calibration System Basic Features:


  • For static and dynamic calibration
  • Calibration range 1.013 – 10-4 hPa
  • Easy to use
  • Chamber ISO/TS 3567- compliant
  • Up to 3 reference gauges for medium accuracy
  • DAkkS-certified reference gauges
  • Flexible
  • We also deliver customized solutions

 

Pfeiffer Calibration System Basic Measurement Accuracies:


Pfeiffer Calibration System Basic Measurement Accuracies, PSA30105, PS A30 105

 

Pfeiffer Calibration System Basic Application:


  • Freeze-drying in the pharmaceutical and food industry
  • Coating systems for optics, ophthalmics, decorative coatings, diffusion barrier layers for PET bottles and packaging films, wear protection coatings for tools, etc., incorporating the use of multiple measuring instruments.
  • Final vacuum measurement in pump production and service workshops
  • Process monitoring and process control for determining the end of the process, in order to produce consistent quality and minimize rejection rates.

 

Pfeiffer Calibration System Basic Dimensions:


Pfeiffer Calibration System Basic Dimensions, PSA30105, PS A30 105


Click Here for Pfeiffer Calibration System Basic Manual


A&J Vacuum Services offers full repair/service of Pfeiffer Calibration System Basic, along with all other brands offered on our website. AJVS also services Pfeiffer Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.


Condition: New
Item#: PN23760 Mfr Part#: PSA30106 / PS A30 106 A Manufacturer: Pfeiffer Vacuum
Price upon request

Pfeiffer Basic Calibration System for Gauges, 110-230 V 50/60 Hz, PSA30106, PS A30 106 A

 

Pfeiffer Calibration System Basic Overview:


The calibration system consists of a turbo pumping station HiCube 80 Eco as main component and a mounted vacuum chamber on top, which is attached by the support on the butterfly valve and the turbo pump respectively on the housing. The calibration system can be switched on and off with the master switch. The display control unit takes ove the control and monitoring. 

The backing pump generates the necessary fore-vacuum for the turbo pump. On top of the vacuum chamber are depending on the unit model several flange connections with different nominal diameters for vacuum gauges. The are closed with blank flanges ex works. The centrally positioned GAV on the vacuum chamber is for central manual gas inlet regulation. The Pirani/Cold cathode transmitter on the vacuum chamber controls the calibration system. 

The vacuum chamber can be closed off from the turbo pump with the manual butterfly valve. The T handle indicates the valve position. The electronic drive unit is supplied with power by the power supply pack and is an inherent part of the turbo pump. It is for inducement, monitoring and control of the turbo pump. The turbo pump is additionally equipped with a venting valve, which vents the turbo pump automatically in case of deactivation or a power cut-off. The HiPace air cooling unit cools the turbo pump during operation.

In view of increasingly stringent quality assurance requirements where the accuracy and reproducibility of the vacuum measured during production and service work is essential as well as the vacuum gauges required for this, the demand for calibration systems is steadily increasing in the market place. In critical processes, the accuracy of vacuum measurements is important for process stability, quality and for monitoring these processes. The pharmaceutical industry requires precise vacuum measurements for safeguarding its high quality product. This is the case particularly in freeze drying expensive drugs. For this reason, regular calibration of vacuum gauges is required. This also applies for final vacuum measurements on vacuum systems in service applications in line with factory or international standards.

To cover the majority of applications, Pfeiffer Vacuum has developed two calibration systems - Basic and Pro system.

 

Pfeiffer Calibration System Basic Structure:


Pfeiffer Calibration System Basic Structure, PSA30105, PS A30 105

 

Pfeiffer Calibration System Basic Features:


  • For static and dynamic calibration
  • Calibration range 1.013 – 10-4 hPa
  • Easy to use
  • Chamber ISO/TS 3567- compliant
  • Up to 3 reference gauges for medium accuracy
  • DAkkS-certified reference gauges
  • Flexible
  • We also deliver customized solutions

 

Pfeiffer Calibration System Basic Measurement Accuracies:


Pfeiffer Calibration System Basic Measurement Accuracies, PSA30105, PS A30 105

 

Pfeiffer Calibration System Basic Application:


  • Freeze-drying in the pharmaceutical and food industry
  • Coating systems for optics, ophthalmics, decorative coatings, diffusion barrier layers for PET bottles and packaging films, wear protection coatings for tools, etc., incorporating the use of multiple measuring instruments.
  • Final vacuum measurement in pump production and service workshops
  • Process monitoring and process control for determining the end of the process, in order to produce consistent quality and minimize rejection rates.

 

Pfeiffer Calibration System Basic Dimensions:


Pfeiffer Calibration System Basic Dimensions, PSA30105, PS A30 105


Click Here for Pfeiffer Calibration System Basic Manual


A&J Vacuum Services offers full repair/service of Pfeiffer Calibration System Basic, along with all other brands offered on our website. AJVS also services Pfeiffer Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.


Condition: New
Item#: PN23761 Mfr Part#: PSA30107 / PS A30 107 Manufacturer: Pfeiffer Vacuum
Price upon request

Pfeiffer Basic Calibration System for Gauges, 110-230 V 50/60 Hz, PSA30107, PS A30 107

 

Pfeiffer Calibration System Basic Overview:


The calibration system consists of a turbo pumping station HiCube 80 Eco as main component and a mounted vacuum chamber on top, which is attached by the support on the butterfly valve and the turbo pump respectively on the housing. The calibration system can be switched on and off with the master switch. The display control unit takes ove the control and monitoring. 

The backing pump generates the necessary fore-vacuum for the turbo pump. On top of the vacuum chamber are depending on the unit model several flange connections with different nominal diameters for vacuum gauges. The are closed with blank flanges ex works. The centrally positioned GAV on the vacuum chamber is for central manual gas inlet regulation. The Pirani/Cold cathode transmitter on the vacuum chamber controls the calibration system. 

The vacuum chamber can be closed off from the turbo pump with the manual butterfly valve. The T handle indicates the valve position. The electronic drive unit is supplied with power by the power supply pack and is an inherent part of the turbo pump. It is for inducement, monitoring and control of the turbo pump. The turbo pump is additionally equipped with a venting valve, which vents the turbo pump automatically in case of deactivation or a power cut-off. The HiPace air cooling unit cools the turbo pump during operation.

In view of increasingly stringent quality assurance requirements where the accuracy and reproducibility of the vacuum measured during production and service work is essential as well as the vacuum gauges required for this, the demand for calibration systems is steadily increasing in the market place. In critical processes, the accuracy of vacuum measurements is important for process stability, quality and for monitoring these processes. The pharmaceutical industry requires precise vacuum measurements for safeguarding its high quality product. This is the case particularly in freeze drying expensive drugs. For this reason, regular calibration of vacuum gauges is required. This also applies for final vacuum measurements on vacuum systems in service applications in line with factory or international standards.

To cover the majority of applications, Pfeiffer Vacuum has developed two calibration systems - Basic and Pro system.

 

Pfeiffer Calibration System Basic Structure:


Pfeiffer Calibration System Basic Structure, PSA30105, PS A30 105

 

Pfeiffer Calibration System Basic Features:


  • For static and dynamic calibration
  • Calibration range 1.013 – 10-4 hPa
  • Easy to use
  • Chamber ISO/TS 3567- compliant
  • Up to 3 reference gauges for medium accuracy
  • DAkkS-certified reference gauges
  • Flexible
  • We also deliver customized solutions

 

Pfeiffer Calibration System Basic Measurement Accuracies:


Pfeiffer Calibration System Basic Measurement Accuracies, PSA30105, PS A30 105

 

Pfeiffer Calibration System Basic Application:


  • Freeze-drying in the pharmaceutical and food industry
  • Coating systems for optics, ophthalmics, decorative coatings, diffusion barrier layers for PET bottles and packaging films, wear protection coatings for tools, etc., incorporating the use of multiple measuring instruments.
  • Final vacuum measurement in pump production and service workshops
  • Process monitoring and process control for determining the end of the process, in order to produce consistent quality and minimize rejection rates.

 

Pfeiffer Calibration System Basic Dimensions:


Pfeiffer Calibration System Basic Dimensions, PSA30105, PS A30 105


Click Here for Pfeiffer Calibration System Basic Manual


A&J Vacuum Services offers full repair/service of Pfeiffer Calibration System Basic, along with all other brands offered on our website. AJVS also services Pfeiffer Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.


Condition: New
Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.