phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
Main Categories

- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Category of products: Pfeiffer Vacuum
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Found 2 products
Item#: PN23762 Mfr Part#: PSA30110 / PS A30 110 A Manufacturer: Pfeiffer Vacuum
Price upon request

Pfeiffer Pro Calibration System for Gauges, 115-230 V 50/60 Hz, PSA30110, PS A30 110 A

 

Pfeiffer Calibration System Pro Overview:


The calibration system consists of a turbo pump HiCube80, backing pump DUO 3 and a vacuum chamber, mounted on a mobil housing. The vacuum chamber can be closed off from the turbo pump with the butterfly valve. With the two manually actuated valves in the bypass the backing pump could be connected directly with the vacuum chamber and/or the fore-vacuum line of the turbo pump.

The calibration system can be switched on and off with the master switch. The display control unit takes over the control and monitoring. The backing pump generates the necessary fore-vacuum for the turbo pump. On top of the vacuum chamber are - depending on the unit model - several flange connections with different nominal diameters for vacuum gauges. They are closed with blank flanges ex works.

The centrally positioned GAV on the vacuum chamber is for central manual gas inlet regulation. The Pirani/Cold cathode transmitter on the vacuum chamber controls the calibration system. The vacuum chamber can be closed off from the turbo pump with the manual butterfly valve. The T handle indicates the valve position. 

The electronic drive unit is supplied with power by the power by the power supply pack and is an inherent part of the turbo pump is additionally equipped with a venting valve, which vents the turbo pump automatically in case of deactivation or a power cut-off. The Hipace ait cooling unit cools the turbo pump during operation. Additionally, the pumping station is equipped with a housing fan.

 

Pfeiffer Calibration System Pro Structure:


Pfeiffer Calibration System Pro Structure, PSA30110, PS A30 110

 

Pfeiffer Calibration System Pro Features:


  • For static and dynamic calibration
  • Calibration range 1.013 – 10-4 hPa
  • Easy to use
  • Chamber ISO/TS 3567-compliant
  • Up to 5 reference gauges for high accuracy
  • DAkkS-certified reference gauges
  • Flexible
  • We also deliver customized solutions

 

Pfeiffer Calibration System Pro Measurement Accuracies:


Pfeiffer Calibration System Pro Measurement Accuracies, PSA30110, PS A30 110

 

Pfeiffer Calibration System Pro Application:


  • Freeze-drying in the pharmaceutical and food industry
  • Coating systems for optics, ophthalmics, decorative coatings, diffusion barrier layers for PET bottles and packaging films, wear protection coatings for tools, etc., incorporating the use of multiple measuring instruments.
  • Final vacuum measurement in pump production and service workshops
  • Process monitoring and process control for determining the end of the process, in order to produce consistent quality and minimize rejection rates.

 

Pfeiffer Calibration System Pro Dimensions:


Pfeiffer Calibration System Pro Dimensions, PSA30110, PS A30 110


Click Here for Pfeiffer Calibration System Pro Manual


A&J Vacuum Services offers full repair/service of Pfeiffer Calibration System Pro, along with all other brands offered on our website. AJVS also services Pfeiffer Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.


Condition: New
Item#: PN23763 Mfr Part#: PSA30111 / PS A30 111 Manufacturer: Pfeiffer Vacuum
Price upon request

Pfeiffer Pro Calibration System for Gauges, 115-230 V 50/60 Hz, PSA30111, PS A30 111

 

Pfeiffer Calibration System Pro Overview:


The calibration system consists of a turbo pump HiCube80, backing pump DUO 3 and a vacuum chamber, mounted on a mobil housing. The vacuum chamber can be closed off from the turbo pump with the butterfly valve. With the two manually actuated valves in the bypass the backing pump could be connected directly with the vacuum chamber and/or the fore-vacuum line of the turbo pump.

The calibration system can be switched on and off with the master switch. The display control unit takes over the control and monitoring. The backing pump generates the necessary fore-vacuum for the turbo pump. On top of the vacuum chamber are - depending on the unit model - several flange connections with different nominal diameters for vacuum gauges. They are closed with blank flanges ex works.

The centrally positioned GAV on the vacuum chamber is for central manual gas inlet regulation. The Pirani/Cold cathode transmitter on the vacuum chamber controls the calibration system. The vacuum chamber can be closed off from the turbo pump with the manual butterfly valve. The T handle indicates the valve position. 

The electronic drive unit is supplied with power by the power by the power supply pack and is an inherent part of the turbo pump is additionally equipped with a venting valve, which vents the turbo pump automatically in case of deactivation or a power cut-off. The Hipace ait cooling unit cools the turbo pump during operation. Additionally, the pumping station is equipped with a housing fan.

 

Pfeiffer Calibration System Pro Structure:


Pfeiffer Calibration System Pro Structure, PSA30110, PS A30 110

 

Pfeiffer Calibration System Pro Features:


  • For static and dynamic calibration
  • Calibration range 1.013 – 10-4 hPa
  • Easy to use
  • Chamber ISO/TS 3567-compliant
  • Up to 5 reference gauges for high accuracy
  • DAkkS-certified reference gauges
  • Flexible
  • We also deliver customized solutions

 

Pfeiffer Calibration System Pro Measurement Accuracies:


Pfeiffer Calibration System Pro Measurement Accuracies, PSA30110, PS A30 110

 

Pfeiffer Calibration System Pro Application:


  • Freeze-drying in the pharmaceutical and food industry
  • Coating systems for optics, ophthalmics, decorative coatings, diffusion barrier layers for PET bottles and packaging films, wear protection coatings for tools, etc., incorporating the use of multiple measuring instruments.
  • Final vacuum measurement in pump production and service workshops
  • Process monitoring and process control for determining the end of the process, in order to produce consistent quality and minimize rejection rates.

 

Pfeiffer Calibration System Pro Dimensions:


Pfeiffer Calibration System Pro Dimensions, PSA30110, PS A30 110


Click Here for Pfeiffer Calibration System Pro Manual


A&J Vacuum Services offers full repair/service of Pfeiffer Calibration System Pro, along with all other brands offered on our website. AJVS also services Pfeiffer Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.


Condition: New
Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.