phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
Main Categories

- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Category of products: ActiveLine
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Found 3 products
Item#: PN07366 Mfr Part#: PTR26855 Manufacturer: Pfeiffer Vacuum
PRICE: $1,050.00
WEB SAVINGS: $51.00
YOU PAY: $999.00

Pfeiffer Vacuum PCR 280, Active Pirani/Capacitance Transmitter, DN 16 ISO KF, PTR 26855  (Direct Replacement for PCR 260, PTR 26850)

 

Product Overview: Pfeiffer Vacuum PCR 280 Dual Pirani/Capacitance Transmitter:


(Direct Replacement for PCR 260, PTR26850)

The Pfeiffer Vacuum PCR 280 Compact Dual Pirani Capacitance Transmitter has been designed for vacuum measurement of gases within pressure range of 5 * 10^[-5] to 1500 mbar. It must not be used for measuring flammable or combustible gases in mixtures containing oxidants (e.g. atmospheric oxygen) within the explosion range.

The Pfeiffer PCR 280 is a dual-combination transmitter consisting of both a Pirani sensor and a diaphragm Capacitance sensor, all within a single measurement chamber. Both sensors are programmed to remain active during the measurement process.

At low pressures, only the signal of the Pirani sensor is utilized for pressure measurement; while at higher pressures, solely that of the diaphragm Capacitance sensor is utilized. To determine the output signal in the intermediate pressure range, both signals are used proportionally to respond to the pressure and establish a reading.

 

A Brief Overview of Pressure Measurement Within a Vacuum System:


Pressure measurement is the analysis of an applied force by a fluid (liquid or gas) on a surface. Pressure is typically measured in units of force per unit of surface area - the Pascal (Pa) is the SI unit commonly used to measure pressure, equivalent to one newton per square meter. Alternatively, pounds per square inch (psi) can also be used as a unit of pressure measurement. In determining the degree of pressure within a vacuum or system, most gauges measure pressure relative to atmospheric pressure, a level referred to as the zero point. Vacuum gauges are especially precise instruments, as they are able to detect the slightest deviations from a state of total vacuum. Any reading greater than total vacuum in such a state constitutes a form of pressure, and thus a vacuum gauge uses total vacuum as the zero point. A vacuum gauge utilizes an absolute scale, whereby the lever begins at the zero point (a complete absence of pressure within a state of total vacuum) and can only change in one direction (as pressure increases).

Differential pressure is likewise an important concept in the field of pressure measurement, as it conveys the difference in pressure between two points or systems. Often times, this refers to the difference between standard atmospheric pressure (typically about 100 kPa at sea level) and the pressure within a vacuum environment. Differential pressure analyses are commonly used in industrial processing systems, and are incorporated within many of the products sold and serviced by A&J Vacuum Services. Differential pressure gauges feature two inlet ports, each connected to one of the two environments where pressure is to be monitored. By monitoring the pressure differential between a near-vacuum environment and one featuring standard atmospheric pressure, the user/operator may obtain an accurate pressure reading by subtracting the difference in total pressure between the two systems.

 

Transmitter Dimensions:


 

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF OPENED OR USED*

 


A&J Vacuum services and repairs Pfeiffer Vacuum PCR 280 Series Dual Pirani/Capacitance Transmitters, along with all other Pfeiffer Vacuum transmitters, pressure gauges, and measurement devices available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier​.


Condition: New
Item#: PN07384 Mfr Part#: PTR26850 Manufacturer: Pfeiffer Vacuum
PRICE: $0.00
YOU PAY: $709.00

THIS ITEM HAS BECOME OBSOLETE. IT HAS BEEN REPLACED BY THE UPDATED PCR 280 MODEL GAUGE. PLEASE REFER TO ITEM # 07366.

 

Product Overview - Pfeiffer Vacuum PCR 260 Dual Pirani/Capacitance Gauge:


The Pfeiffer Vacuum PCR 260 Compact Dual Pirani Capacitance Gauge has been designed for vacuum measurement of gases within pressure range of 5 * 10^[-5] to 1500 mbar. It must not be used for measuring flammable or combustible gases in mixtures containing oxidants (e.g. atmospheric oxygen) within the explosion range.

The Pfeiffer PCR 260 is a dual-combination transmitter consisting of both a Pirani sensor and a diaphragm Capacitance sensor, all within a single measurement chamber. Both sensors are programmed to remain active during the measurement process.

At low pressures, only the signal of the Pirani sensor is utilized for pressure measurement; while at higher pressures, solely that of the diaphragm Capacitance sensor is utilized. To determine the output signal in the intermediate pressure range, both signals are used proportionally to respond to the pressure and establish a reading.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF OPENED OR USED*


A&J Vacuum services and repairs Pfeiffer Vacuum PCR 260 Series Dual Pirani/Capacitance Transmitters, along with all other Pfeiffer Vacuum transmitters, pressure gauges, and measurement devices available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier​.


Condition: New
Item#: PN23123 Mfr Part#: PTR26856 Manufacturer: Pfeiffer Vacuum
PRICE: $1,000.00
WEB SAVINGS: $75.00
YOU PAY: $925.00

Pfeiffer Vacuum PCR 280 Pirani / Capacitance Vacuum Gauge, 80 °C, DN 16 CF-F, PTR26856 / PT R26 858

 

Product Features - Pfeiffer Vacuum Pirani/Capcitance PCR 280 Gauge (w/ DN 16 CF-F Flange):


  • Utilized for Accurate Gas-Type Independent Pressure Measurement of Venting Procedures
  • Display Range: 5 * 10^[-5] to 1500 hPa
  • Two Sensors / Modes of Measurement in One Gauge Head (Pirani and Capacitance Diaphragm)
  • Metal-Sealed Upon Arrival
  • Bakeout Remperature: 80 °C
  • Output Signal: 1.2 – 8.68 V Logarithm of Pressure
  • Voltage supply: 15 – 30 V DC

 

A Brief Overview of Pressure Measurement Within a Vacuum System:


Pressure measurement is the analysis of an applied force by a fluid (liquid or gas) on a surface. Pressure is typically measured in units of force per unit of surface area - the Pascal (Pa) is the SI unit commonly used to measure pressure, equivalent to one newton per square meter. Alternatively, pounds per square inch (psi) can also be used as a unit of pressure measurement. In determining the degree of pressure within a vacuum or system, most gauges measure pressure relative to atmospheric pressure, a level referred to as the zero point. Vacuum gauges are especially precise instruments, as they are able to detect the slightest deviations from a state of total vacuum. Any reading greater than total vacuum in such a state constitutes a form of pressure, and thus a vacuum gauge uses total vacuum as the zero point. A vacuum gauge utilizes an absolute scale, whereby the lever begins at the zero point (a complete absence of pressure within a state of total vacuum) and can only change in one direction (as pressure increases).

Differential pressure is likewise an important concept in the field of pressure measurement, as it conveys the difference in pressure between two points or systems. Often times, this refers to the difference between standard atmospheric pressure (typically about 100 kPa at sea level) and the pressure within a vacuum environment. Differential pressure analyses are commonly used in industrial processing systems, and are incorporated within many of the products sold and serviced by A&J Vacuum Services. Differential pressure gauges feature two inlet ports, each connected to one of the two environments where pressure is to be monitored. By monitoring the pressure differential between a near-vacuum environment and one featuring standard atmospheric pressure, the user/operator may obtain an accurate pressure reading by subtracting the difference in total pressure between the two systems.

 

Gauge Dimensions:


 

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF OPENED OR USED*

 


A&J Vacuum services and repairs Pfeiffer Vacuum PCR 280 Series Dual Pirani/Capacitance Gauges, along with all other Pfeiffer Vacuum pressure gauges, transmitters, and measurement devices available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier​.


Condition: New
Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.