Fully refurbished Pfeiffer Vacuum TPH 060 PMP01400 Turbo Pump coupled with a DN 63 ISO-K Inlet Flange and DN 16 ISO-KF Outlet Flange. This particular Turbomolecular Drag Pump has a pumping velocity of 56 liters per second and a final pressure of 1 x 10-11. It has been thoroughly examined and is ready for broad range of applications within the research and industrial industries. The TPH 060 Turbo Pump comes with an entire 12-Month Warranty.
This Pfeiffer Pump has a wear free permanent magnetic bearing at the high vacuum side and a oil lubricated ceramic bearing at the backing side. The Turbo Pumps TMH and TMU models are identical in terms of design. They only differ in their intake flange.
A turbopump is a gas turbine that is made up of two independent components ; a rotodynamic pump and a driving turbine. They can be mounted on the same shaft or customarily geared together. The design of a turbopump is to produce a high pressure fluid for feeding a combustion chamber or other use. Visit the turbo pump wiki page for more information.
A turbomolecular pump is a form of vacuum pump similar to a turbopump which is used to obtain and hold a high vacuum. These pumps work on the principle that gas particles can be given momentum in a wanted direction by reiterated collision with a traveling solid surface. In a turbomolecular pump, a quickly spinning turbine rotor 'strikes' gas particles from the intake of the pump towards the exhaust in order to make or hold a vacuum. Visit the turbomolecular pump wiki page for more information.
A&J Vacuum repair / rebuild and service all Pfeiffer TPH 060, TPU 060, TPH 062, TPU 062 / PM P02 400 and PM P02 401 Turbo Pumps, Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
TPH 062 - TPU 062 | |
Inlet | DN63 ISO-K/DN 63 CF-F |
Outlet | DN16 ISO-KF |
Volume flow rate for | |
N2 l/s | 56 |
He l/s | 52 |
H2 l/s | 45 |
Recommended backing pump: m^3/h | 1,5 |
Electronic drive unit | TCP 121 (TCP 121) / 380 |
Compression ratio for | |
N2 | 1x10^8 |
He | 7x10^3 |
H2 | 6x10^2 |
Theoretical final pressure | 10^-11 |
Final pressure mbar | <1x10^-10 |
Final pressure mbar | <1x10^-9 |
Final pressure mbar | <1x10^-8 |
Rated rotation speed 1/min | 90000 |
Stand-by rotation 1/min | 60000 |
Run-up time min | 2 |
Operating fluid filling cm3 | 4 |
Type of cooling, standard, Water temperature at cooling water connection °C |
5-25 |
Cooling water con-sumption with water-cooling l/h | 15 |
Permissible ambient temperature for air cooling °C | 0-35 |
Permissible magnetic field, max. mT | 7 |
Weight kg | 3,6/3,8 |
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Fully refurbished Pfeiffer Vacuum TPH 060 PMP01400 Turbo Pump coupled with a DN 63 ISO-K Inlet Flange and DN 16 ISO-KF Outlet Flange. This particular Turbomolecular Drag Pump has a pumping velocity of 56 liters per second and a final pressure of 1 x 10-11. It has been thoroughly examined and is ready for broad range of applications within the research and industrial industries. The TPH 060 Turbo Pump comes with an entire 12-Month Warranty.
This Pfeiffer Pump has a wear free permanent magnetic bearing at the high vacuum side and a oil lubricated ceramic bearing at the backing side. The Turbo Pumps TMH and TMU models are identical in terms of design. They only differ in their intake flange.
A turbopump is a gas turbine that is made up of two independent components ; a rotodynamic pump and a driving turbine. They can be mounted on the same shaft or customarily geared together. The design of a turbopump is to produce a high pressure fluid for feeding a combustion chamber or other use. Visit the turbo pump wiki page for more information.
A turbomolecular pump is a form of vacuum pump similar to a turbopump which is used to obtain and hold a high vacuum. These pumps work on the principle that gas particles can be given momentum in a wanted direction by reiterated collision with a traveling solid surface. In a turbomolecular pump, a quickly spinning turbine rotor 'strikes' gas particles from the intake of the pump towards the exhaust in order to make or hold a vacuum. Visit the turbomolecular pump wiki page for more information.
A&J Vacuum repair / rebuild and service all Pfeiffer TPH 060, TPU 060, TPH 062, TPU 062 / PM P02 400 and PM P02 401 Turbo Pumps, Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
TPH 062 - TPU 062 | |
Inlet | DN63 ISO-K/DN 63 CF-F |
Outlet | DN16 ISO-KF |
Volume flow rate for | |
N2 l/s | 56 |
He l/s | 52 |
H2 l/s | 45 |
Recommended backing pump: m^3/h | 1,5 |
Electronic drive unit | TCP 121 (TCP 121) / 380 |
Compression ratio for | |
N2 | 1x10^8 |
He | 7x10^3 |
H2 | 6x10^2 |
Theoretical final pressure | 10^-11 |
Final pressure mbar | <1x10^-10 |
Final pressure mbar | <1x10^-9 |
Final pressure mbar | <1x10^-8 |
Rated rotation speed 1/min | 90000 |
Stand-by rotation 1/min | 60000 |
Run-up time min | 2 |
Operating fluid filling cm3 | 4 |
Type of cooling, standard, Water temperature at cooling water connection °C |
5-25 |
Cooling water con-sumption with water-cooling l/h | 15 |
Permissible ambient temperature for air cooling °C | 0-35 |
Permissible magnetic field, max. mT | 7 |
Weight kg | 3,6/3,8 |
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.