Pfeiffer Vacuum TPH 180H C Plasma Turbo Pump, DN 100 ISO, PMP01575
Item#: PN00149 Mfr Part#: PMP01575 / PM P01 575 Manufacturer: Pfeiffer Vacuum
Condition: Remanufactured In Stock
Remanufactured Pfeiffer Vacuum TPH-180H C Plasma Turbo Pump, DN 100 ISO, PMP01575, TPH 180HC, PM P01 575

Features:
  • Fully Remanufactured
  • Like New
  • Full Warranty
  • Ultimate Pressure: < 1 x 10-10 mbar

PRICE: $5,875.00
WEB SAVINGS: $925.00
YOU PAY: $4,950.00
Item#: PN00149 Mfr Part#: PMP01575 / PM P01 575
Pfeiffer Vacuum TPH 180H C Plasma Turbo Pump, DN 100 ISO, PMP01575
Item#: PN00149 Mfr Part#: PMP01575 / PM P01 575 Manufacturer: Pfeiffer Vacuum

Fully Refurbished Pfeiffer TPH180HC Corrosive Turbo Pump with ISO100-K Inlet Flange, KF25 Outlet Flange. PMP01575, TPH-180HC PM P01 575

 

Pfeiffer TPH 180 HC Overview:


Pfeiffer TPH-180HC Turbo Pump has a free of wear permanent upper magnetic bearing at high vacuum side and oil lubricated ceramic bearing at the lower backing side.

The Pfeiffer 180 HC Corrosive Turbo Pumps TMH and TMU models are identical in terms of design. They only differ in their intake flange.

TPH-180HC Corrosive Turbo pump has been designed for a wide range of applications in research industry.

 

TPH 180HC Turbo Pump Typical Applications


  • Thin film deposition
  • Space simulation
  • Cryogenic research
  • Nuclear physics, Plasma physics, High energy physics
  • Particle accelerators - Storage rings
  • Air or Water Cooling available.
  • The Turbo Pumps TPH and TPU models are identical in terms of design. They only differ in their intake flange.
  • The pumps have a free of wear permanent magnetic bearing at high vacuum side and oil lubricated ceramic bearing at the backing side.
  • Turbo pump designed for a wide range of applications in research industry.
  • The Pfeiffer Balzers TCP -310 or TCP -380 Turbo Pump controller is needed to operate TPH / TPU 180HC

 

Pfeiffer TMH 180H C Dimensions:


Pfeiffer TPH - 180 H C, PMP01575


A&J Vacuum repair / rebuild and service Pfeiffer  TPH-180 HC CorrosiveTurbo Pumps, PMP01575 Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Fully Refurbished Pfeiffer TPH180HC Corrosive Turbo Pump with ISO100-K Inlet Flange, KF25 Outlet Flange. PMP01575, TPH-180HC PM P01 575

 

Pfeiffer TMH 180H C Technical Data:


Pfeiffer TPH - 180 H C, PMP01575


A&J Vacuum repair / rebuild and service Pfeiffer  TPH-180 HC CorrosiveTurbo Pumps, PMP01575 Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Vacuum TPH 180H C Plasma Turbo Pump, DN 100 ISO, PMP01575
Item#: PN00149 Mfr Part#: PMP01575 / PM P01 575 Manufacturer: Pfeiffer Vacuum

Fully Refurbished Pfeiffer TPH180HC Corrosive Turbo Pump with ISO100-K Inlet Flange, KF25 Outlet Flange. PMP01575, TPH-180HC PM P01 575

 

Pfeiffer TPH 180 HC Overview:


Pfeiffer TPH-180HC Turbo Pump has a free of wear permanent upper magnetic bearing at high vacuum side and oil lubricated ceramic bearing at the lower backing side.

The Pfeiffer 180 HC Corrosive Turbo Pumps TMH and TMU models are identical in terms of design. They only differ in their intake flange.

TPH-180HC Corrosive Turbo pump has been designed for a wide range of applications in research industry.

 

TPH 180HC Turbo Pump Typical Applications


  • Thin film deposition
  • Space simulation
  • Cryogenic research
  • Nuclear physics, Plasma physics, High energy physics
  • Particle accelerators - Storage rings
  • Air or Water Cooling available.
  • The Turbo Pumps TPH and TPU models are identical in terms of design. They only differ in their intake flange.
  • The pumps have a free of wear permanent magnetic bearing at high vacuum side and oil lubricated ceramic bearing at the backing side.
  • Turbo pump designed for a wide range of applications in research industry.
  • The Pfeiffer Balzers TCP -310 or TCP -380 Turbo Pump controller is needed to operate TPH / TPU 180HC

 

Pfeiffer TMH 180H C Dimensions:


Pfeiffer TPH - 180 H C, PMP01575


A&J Vacuum repair / rebuild and service Pfeiffer  TPH-180 HC CorrosiveTurbo Pumps, PMP01575 Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Fully Refurbished Pfeiffer TPH180HC Corrosive Turbo Pump with ISO100-K Inlet Flange, KF25 Outlet Flange. PMP01575, TPH-180HC PM P01 575

 

Pfeiffer TMH 180H C Technical Data:


Pfeiffer TPH - 180 H C, PMP01575


A&J Vacuum repair / rebuild and service Pfeiffer  TPH-180 HC CorrosiveTurbo Pumps, PMP01575 Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.