Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50
Item#: PN15277 Mfr Part#: ISP-50 Manufacturer: Anest Iwata
Condition: New
New Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50

Features:
  • Pumping Speed L/min 50 (50Hz)
  • Ultimate Pressure: < 20 Pa (50Hz) / < 15 Pa (60Hz)
  • Inlet Connection: NW 25
  • Air Cooled

PRICE: $5,135.00
WEB SAVINGS: $746.00
YOU PAY: $4,389.00
Item#: PN15277 Mfr Part#: ISP-50
Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50
Item#: PN15277 Mfr Part#: ISP-50 Manufacturer: Anest Iwata

Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50

 

Anest Iwata ISP-50 Technical Data:


The Anest Iwata ISP-50 Dry Scroll Pumps offer a clean dry vacuum enviroment and elimates the nuisance of cumbersome lubricant maintenance or sealing water administration.

The ISP-50 Dry Pump is free from installation restrictions because of its air-cooled system, and does not require water cooling. The air cooling system eliminates the need for the burdensome job of maintaining cooling water and allows the pump to be installed in place where it was formerly difficult to install. 

The ISP Series pumps are oil-free, solving many issues with contamination and maintenance problems. The ISP Vacuum Pumps are used by many customers in a wide range of applications from cutting-edge industries in the filed of physical and chemical science to general purpose uses.

Pumping humid gases can cause condensed moisture to remain in the pump. In order to extend the life of the pump, we utilized the Air Flush System to remove any moisture. The ISP-50 Scroll Vacuum Pump is equipped with Air Flush Port, which pumps out the remaining moisture left over from pumping humid gases and maintains the ultimate pressure.

Anest Iwata ISP-50 series vacuum pumps maintain low power consumption from atmosphere to maximum pressure.

The ISP-50 Vacuum Pump should be used at ambient operation temperature in the range of 5ºC to 40ºC.

This pumping system is suitable for clean processes only. Do not use explosive, flammable, toxic or corrosive substances or substances which contain chemicals, solvents or particles.

 

Anest Iwata ISP-50 Features:


  • Energy efficient
  • Quiet
  • Low vibration
  • Longer maintenance cycle

Anest Iwata ISP 50 Info Graphs

Anest Iwata ISP-50 Applications:


The dry scroll ISP Vacuum Pumps offer a wide range of pumping speeds and ultimate pressure that are used in many applications in the research and development and production areas, such as;

  • Sputtering Equipment, Vacuum Depostition Equipment, Ion Plating Equipment

  • Electron Microscope

    • Uses scattered electrons and transmitted 

  • Mass Spectrometry

    • Measures the mass of a molecule. Utilizes vacuum to convert the molecule to a gas-phase ion.

  • Sputtering

    • Involves ejecting material from a source target onto a substrate.

  • Evaporation Deposition

    • Coating source material is evaporated in a vacuum.

  • Vacuum Sterilizer 

    • Utilizes a series of sterilizing gas injections and evacuations with a vacuum system. 

  • Vacuum Freeze Drying

    • Pressure is lowered to create ice sublimation. Vacuum speeds up the sublimation.

  • Cryogenics

    • Vacuum pumps are used in conjunction with Cryo pumps for chamber evacuation and gas regeneration. 

  • Vacuum Heat Treatment

    • Preventing oxidation and removing absorbed gases for heat treatment under vacuum.

  • Accelerator, Synchrotron Radiation

    • Vacuum is required to keep electrons and photons from being slowed down by colliding with atoms and molecules.

  • Surface Modification, Electron Beam Process

  • Gas Recovery Devices

  • Vacuum Equipment

  • Leak Detectors

    • Checking leakage by measuring pressure change overtime while under vacuum. 

  • Device Handling System

  • Vacuum Furnace, Heat Treatment Furnace

  • Laboratory Use

  • Vacuum Packaging Machine

 

Anest Iwata ISP-50 Dimensions:


Anest Iwata ISP 50 Dimensions


Click Here to view Anest Iwata ISP-50 Dry Scroll Vacuum Pump Instruction Manual.


A&J Vacuum Services, Inc is Anest Iwata authorized repair / rebuild and service center for all Scroll Dry Vacuum Pumps along with all other. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

This item is non-returnable/non-refundable

Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50

 

Anest Iwata ISP-50 Overview:



Click Here to view Anest Iwata ISP-50 Dry Scroll Vacuum Pump Instruction Manual.


A&J Vacuum Services, Inc is Anest Iwata authorized repair / rebuild and service center for all Scroll Dry Vacuum Pumps along with all other. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Name
Price
$589.00
$465.00
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50
Item#: PN15277 Mfr Part#: ISP-50 Manufacturer: Anest Iwata

Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50

 

Anest Iwata ISP-50 Technical Data:


The Anest Iwata ISP-50 Dry Scroll Pumps offer a clean dry vacuum enviroment and elimates the nuisance of cumbersome lubricant maintenance or sealing water administration.

The ISP-50 Dry Pump is free from installation restrictions because of its air-cooled system, and does not require water cooling. The air cooling system eliminates the need for the burdensome job of maintaining cooling water and allows the pump to be installed in place where it was formerly difficult to install. 

The ISP Series pumps are oil-free, solving many issues with contamination and maintenance problems. The ISP Vacuum Pumps are used by many customers in a wide range of applications from cutting-edge industries in the filed of physical and chemical science to general purpose uses.

Pumping humid gases can cause condensed moisture to remain in the pump. In order to extend the life of the pump, we utilized the Air Flush System to remove any moisture. The ISP-50 Scroll Vacuum Pump is equipped with Air Flush Port, which pumps out the remaining moisture left over from pumping humid gases and maintains the ultimate pressure.

Anest Iwata ISP-50 series vacuum pumps maintain low power consumption from atmosphere to maximum pressure.

The ISP-50 Vacuum Pump should be used at ambient operation temperature in the range of 5ºC to 40ºC.

This pumping system is suitable for clean processes only. Do not use explosive, flammable, toxic or corrosive substances or substances which contain chemicals, solvents or particles.

 

Anest Iwata ISP-50 Features:


  • Energy efficient
  • Quiet
  • Low vibration
  • Longer maintenance cycle

Anest Iwata ISP 50 Info Graphs

Anest Iwata ISP-50 Applications:


The dry scroll ISP Vacuum Pumps offer a wide range of pumping speeds and ultimate pressure that are used in many applications in the research and development and production areas, such as;

  • Sputtering Equipment, Vacuum Depostition Equipment, Ion Plating Equipment

  • Electron Microscope

    • Uses scattered electrons and transmitted 

  • Mass Spectrometry

    • Measures the mass of a molecule. Utilizes vacuum to convert the molecule to a gas-phase ion.

  • Sputtering

    • Involves ejecting material from a source target onto a substrate.

  • Evaporation Deposition

    • Coating source material is evaporated in a vacuum.

  • Vacuum Sterilizer 

    • Utilizes a series of sterilizing gas injections and evacuations with a vacuum system. 

  • Vacuum Freeze Drying

    • Pressure is lowered to create ice sublimation. Vacuum speeds up the sublimation.

  • Cryogenics

    • Vacuum pumps are used in conjunction with Cryo pumps for chamber evacuation and gas regeneration. 

  • Vacuum Heat Treatment

    • Preventing oxidation and removing absorbed gases for heat treatment under vacuum.

  • Accelerator, Synchrotron Radiation

    • Vacuum is required to keep electrons and photons from being slowed down by colliding with atoms and molecules.

  • Surface Modification, Electron Beam Process

  • Gas Recovery Devices

  • Vacuum Equipment

  • Leak Detectors

    • Checking leakage by measuring pressure change overtime while under vacuum. 

  • Device Handling System

  • Vacuum Furnace, Heat Treatment Furnace

  • Laboratory Use

  • Vacuum Packaging Machine

 

Anest Iwata ISP-50 Dimensions:


Anest Iwata ISP 50 Dimensions


Click Here to view Anest Iwata ISP-50 Dry Scroll Vacuum Pump Instruction Manual.


A&J Vacuum Services, Inc is Anest Iwata authorized repair / rebuild and service center for all Scroll Dry Vacuum Pumps along with all other. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Anest Iwata ISP-50 Dry Scroll Vacuum Pump, Vertical Inlet, Single Phase Motor, ISP50, ISP 50

 

Anest Iwata ISP-50 Overview:



Click Here to view Anest Iwata ISP-50 Dry Scroll Vacuum Pump Instruction Manual.


A&J Vacuum Services, Inc is Anest Iwata authorized repair / rebuild and service center for all Scroll Dry Vacuum Pumps along with all other. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.