- Cold Traps
Vacuubrand Cooling Fan for MD 4 NT Diaphragm Vacuum Pump, 640111
Item#: PN15279 Mfr Part#: 640111 Manufacturer: Vacuubrand
Condition: New
New Vacuubrand Cooling Fan for MD 4 NT Diaphragm Vacuum Pump, 640111

Features:

Price upon request
Item#: PN15279 Mfr Part#: 640111
Vacuubrand Cooling Fan for MD 4 NT Diaphragm Vacuum Pump, 640111
Item#: PN15279 Mfr Part#: 640111 Manufacturer: Vacuubrand

Overview:

Vacuubrand Cooling Fan for MD 4 NT Diaphragm Vacuum Pump.

These three-stage diaphragm pumps are an excellent solution for continuous, oil-free pumping of non-corrosive gases.

They reach an excellent ultimate vacuum of 1 mbar.

All parts in contact with pumped gases and vapors are made of aluminum, stainless steel and carefully selected plastics suitable for a wide range of applications with non-corrosive gases.

The new NT-series provides whisper quiet and ultra-low vibration operation, high leak tightness and improved performance.

The highly flexible fabric-reinforced double diaphragm made of FKM is ideal for extended operating life.

Features:

  • Contamination-free pumping and evacuation
  • High flow rate even near ultimate vacuum
  • Whisper quiet
  • Very low vibration
  • Exceptionally long diaphragm life and maintenance-free drive system for low lifetime costs

 

This item is non-returnable/non-refundable
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Vacuubrand Cooling Fan for MD 4 NT Diaphragm Vacuum Pump, 640111
Item#: PN15279 Mfr Part#: 640111 Manufacturer: Vacuubrand

Overview:

Vacuubrand Cooling Fan for MD 4 NT Diaphragm Vacuum Pump.

These three-stage diaphragm pumps are an excellent solution for continuous, oil-free pumping of non-corrosive gases.

They reach an excellent ultimate vacuum of 1 mbar.

All parts in contact with pumped gases and vapors are made of aluminum, stainless steel and carefully selected plastics suitable for a wide range of applications with non-corrosive gases.

The new NT-series provides whisper quiet and ultra-low vibration operation, high leak tightness and improved performance.

The highly flexible fabric-reinforced double diaphragm made of FKM is ideal for extended operating life.

Features:

  • Contamination-free pumping and evacuation
  • High flow rate even near ultimate vacuum
  • Whisper quiet
  • Very low vibration
  • Exceptionally long diaphragm life and maintenance-free drive system for low lifetime costs

 

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.