Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb
Item#: PN15330 Mfr Part#: Krytox1525 Manufacturer: Du Pont
Condition: New In Stock
New Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb

Features:
  • Average Molecular Weight: 4600
  • Vapor Pressure: 1x10E-7 torr @ 20 degrees Celsius
  • Kinematic Viscosity: 261 mm^2/s @ 20 degrees Celsius
  • Density: 1.90 g/cc

PRICE: $250.00
YOU PAY: $250.00
Item#: PN15330 Mfr Part#: Krytox1525
Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb
Item#: PN15330 Mfr Part#: Krytox1525 Manufacturer: Du Pont

Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb


Overview

Krytox Oils and Greases, Solvents and Additives have been tested, piloted and proven in a broad range of industries and operation environments.

Krytox vacuum pump fluids are used in applications where conventional vacuum pump oils cause safety, waste disposal and maintenance problems. They are nonflammable and eliminate the chance of fire in pumps. They are nonreactive and safe to use in oxygen systems.

They can replace competitive PFPE fluids as well as any other type of vacuum fluid. Krytox fluids do not contain acetal groups, which are susceptible to attack by Lewis acids. This gives Krytox superior stability as a vacuum pump fluid. Krytox vacuum fluids are precisely distilled to provide low vapor pressures and give superior performance. In addition, Krytox fluids are recyclable.

Krytox XP VPF oils contain a soluble additive to prevent rust. This patented additive enhances the performance of Krytox VPF fluids, giving them improved performance properties. The long-term antirust properties repel moisture, providing extra protection from corrosion of metal parts and bearing surfaces.

Krytox_1525_Oil_Descrip_Chart

 


A&J Vacuum Repairs / Rebuilds and Services Rotary Vane Vacuum Pumps and other vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb


Technical Data

Average Molecular Weight: 4600

Vapor Pressure: 1x10E-7 torr @ 20 degrees Celsius

Kinematic Viscosity: 261 mm^2/s @ 20 degrees Celsius

Density: 1.90 g/cc

Pour Point: -48 degress Celsius

Distillation Range at 0.4 torr: 200 degrees Celsius at 10%

Heat of Vaporization: 6 cal/g at 150-250 degrees Celsius

Volatility at 22 hr: 0.5% at 149 degrees Celsius

Surface Tension: 19 dyn/cm at 25 degrees Celsius

 


A&J Vacuum Repairs / Rebuilds and Services Rotary Vane Vacuum Pumps and other vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb
Item#: PN15330 Mfr Part#: Krytox1525 Manufacturer: Du Pont

Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb


Overview

Krytox Oils and Greases, Solvents and Additives have been tested, piloted and proven in a broad range of industries and operation environments.

Krytox vacuum pump fluids are used in applications where conventional vacuum pump oils cause safety, waste disposal and maintenance problems. They are nonflammable and eliminate the chance of fire in pumps. They are nonreactive and safe to use in oxygen systems.

They can replace competitive PFPE fluids as well as any other type of vacuum fluid. Krytox fluids do not contain acetal groups, which are susceptible to attack by Lewis acids. This gives Krytox superior stability as a vacuum pump fluid. Krytox vacuum fluids are precisely distilled to provide low vapor pressures and give superior performance. In addition, Krytox fluids are recyclable.

Krytox XP VPF oils contain a soluble additive to prevent rust. This patented additive enhances the performance of Krytox VPF fluids, giving them improved performance properties. The long-term antirust properties repel moisture, providing extra protection from corrosion of metal parts and bearing surfaces.

Krytox_1525_Oil_Descrip_Chart

 


A&J Vacuum Repairs / Rebuilds and Services Rotary Vane Vacuum Pumps and other vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

Krytox 1525 PFPE Inert Pump Oil For Rotary Vane Vacuum Pumps, 0.5 kg / 1.1 lb


Technical Data

Average Molecular Weight: 4600

Vapor Pressure: 1x10E-7 torr @ 20 degrees Celsius

Kinematic Viscosity: 261 mm^2/s @ 20 degrees Celsius

Density: 1.90 g/cc

Pour Point: -48 degress Celsius

Distillation Range at 0.4 torr: 200 degrees Celsius at 10%

Heat of Vaporization: 6 cal/g at 150-250 degrees Celsius

Volatility at 22 hr: 0.5% at 149 degrees Celsius

Surface Tension: 19 dyn/cm at 25 degrees Celsius

 


A&J Vacuum Repairs / Rebuilds and Services Rotary Vane Vacuum Pumps and other vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.