Dow Corning Laboratory High Vacuum Grease for Joints and O-Rings, Silicon, 1/4 oz, 976V
Item#: PN15470 Mfr Part#: 976V Manufacturer: Dow Corning
Condition: New
New Dow Corning Laboratory High Vacuum Grease for Joints and O-Rings, Silicon, 1/4 oz, 976V

Features:

PRICE: $7.34
WEB SAVINGS: $0.14
YOU PAY: $7.20
Item#: PN15470 Mfr Part#: 976V
Dow Corning Laboratory High Vacuum Grease for Joints and O-Rings, Silicon, 1/4 oz, 976V
Item#: PN15470 Mfr Part#: 976V Manufacturer: Dow Corning

Overview:

Dow Corning Laboratory High Vacuum Grease is designed for sealing and lubricating vacuum and pressure systems.

It is a stiff, nonmelting silicone lubricating material that maintains its consistency.

Features:

  • Good lubricating and sealing ability
  • Low volatility to hold deep vacuums
  • Nonmelting
  • Good thermal stability
  • Excellent resistance to water, chemicals, high and low temperatures
  • Insoluble in water, methanol, ethanol, acetone, glycol, and glycerine
  • Unaffected by most vegetable and minerals oils, many organic compounds, and most common gases
  • Resistant to most aqueous solutions of inorganic salts and to dilute acids and alkalies

Applications:

  • Recommended for vacuums reaching between 1 x 10-5 and 1 x 10-6 torr. (It is recommended that the grease be preconditioned under vacuum and temperature until these limits are reached to avoid sample contamination.)
  • Seals and lubricates chemical processing equipment
  • Sealing vacuum and pressure systems
  • Lubricate synthetic rubber gaskets and seals in high temperature applications

 

This item is non-returnable/non-refundable
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Dow Corning Laboratory High Vacuum Grease for Joints and O-Rings, Silicon, 1/4 oz, 976V
Item#: PN15470 Mfr Part#: 976V Manufacturer: Dow Corning

Overview:

Dow Corning Laboratory High Vacuum Grease is designed for sealing and lubricating vacuum and pressure systems.

It is a stiff, nonmelting silicone lubricating material that maintains its consistency.

Features:

  • Good lubricating and sealing ability
  • Low volatility to hold deep vacuums
  • Nonmelting
  • Good thermal stability
  • Excellent resistance to water, chemicals, high and low temperatures
  • Insoluble in water, methanol, ethanol, acetone, glycol, and glycerine
  • Unaffected by most vegetable and minerals oils, many organic compounds, and most common gases
  • Resistant to most aqueous solutions of inorganic salts and to dilute acids and alkalies

Applications:

  • Recommended for vacuums reaching between 1 x 10-5 and 1 x 10-6 torr. (It is recommended that the grease be preconditioned under vacuum and temperature until these limits are reached to avoid sample contamination.)
  • Seals and lubricates chemical processing equipment
  • Sealing vacuum and pressure systems
  • Lubricate synthetic rubber gaskets and seals in high temperature applications

 

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.