phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301
Item#: PN17366 Mfr Part#: R0343301 Manufacturer: Agilent Technologies / Varian
Condition: New
New Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301

Features:
  • Operating Voltage (HV range): 3 kV DC
  • Sensitivity: 2.5 A/Torr plus 100 percent
  • Measurement Range: 10-3 to 10-11 Torr
  • Electrical Connector: SHV style, 5 kV rated

Price upon request
Item#: PN17366 Mfr Part#: R0343301
Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301
Item#: PN17366 Mfr Part#: R0343301 Manufacturer: Agilent Technologies / Varian

Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301

 

Agilent IMG 300 UHV Overview:


The Agilent Technologies IMG-300 Inverted Magnetron Gauge combines excellent ultra-high vacuum measurement capability where stable UHV pressure measurement and fast pressure response are equally critical.

Minimal outgassing from within the gauge occurs, since there is no hot filament. The gauge is electron or photon emission-free, so there is no disruption to the experimental process. The IMG-300 is easily interfaced with the Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool.

This sensor is optimized for UHV applications such as particle accelerators, synchrotron light beam lines and energy research applications.

 

Agilent IMG 300 UHV Features:


  • Optimized for UHV applications
  • Superior sensitivity at UHV pressures
  • Minimal outgassing from within the gauge
  • Radiation-resistant and bakeable to 250º C during operation

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Agilent IMG 300 Dimensions:


Agilent IMG 300, R0343301


Click Here for Agilent IMG 300 Manual


A&J Vacuum Services offers full repair/service of Agilent, along with all other brands offered on our website. AJVS also services Agilent pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301

 

Agilent IMG 300 UHV Technical Data:


Measurement range
1 x 10-3 Torr to 1 x 10-11 Torr
1 x 10-1 Torr to 1 x 10-9 Pascal
Measurement precision
+ 50 % within a pressure decade standard
+ 20 % with STARRS Calibration
Temperature limits
Operating: 0? C to 250? C
Storage: -15 to 80? C
Bake out: 250? C maximum with cable and magnet attached
Pressure response time
< 50 milliseconds @ UHV pressures
Ignition response (starting time)
< 30 seconds @ 1 x 10-10 Torr
Operating voltage
3 kilovolts
Materials exposed to vacuum
Stainless steel, nickel, glass, nickel alloy 52
Sensitivity
2 A / Torr + 20% at 5 x 10-6 Torr

Click Here for Agilent IMG 300 Manual


A&J Vacuum Services offers full repair/service of Agilent, along with all other brands offered on our website. AJVS also services Agilent pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301
Item#: PN17366 Mfr Part#: R0343301 Manufacturer: Agilent Technologies / Varian

Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301

 

Agilent IMG 300 UHV Overview:


The Agilent Technologies IMG-300 Inverted Magnetron Gauge combines excellent ultra-high vacuum measurement capability where stable UHV pressure measurement and fast pressure response are equally critical.

Minimal outgassing from within the gauge occurs, since there is no hot filament. The gauge is electron or photon emission-free, so there is no disruption to the experimental process. The IMG-300 is easily interfaced with the Agilent XGS-600 gauge controller for integration into a variety of vacuum systems, or for use as a stand-alone pressure measurement tool.

This sensor is optimized for UHV applications such as particle accelerators, synchrotron light beam lines and energy research applications.

 

Agilent IMG 300 UHV Features:


  • Optimized for UHV applications
  • Superior sensitivity at UHV pressures
  • Minimal outgassing from within the gauge
  • Radiation-resistant and bakeable to 250º C during operation

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Agilent IMG 300 Dimensions:


Agilent IMG 300, R0343301


Click Here for Agilent IMG 300 Manual


A&J Vacuum Services offers full repair/service of Agilent, along with all other brands offered on our website. AJVS also services Agilent pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Agilent Technologies IMG 300 UHV Inverted Magnetron Vacuum Gauge, 2 3/4" CFF, R0343301

 

Agilent IMG 300 UHV Technical Data:


Measurement range
1 x 10-3 Torr to 1 x 10-11 Torr
1 x 10-1 Torr to 1 x 10-9 Pascal
Measurement precision
+ 50 % within a pressure decade standard
+ 20 % with STARRS Calibration
Temperature limits
Operating: 0? C to 250? C
Storage: -15 to 80? C
Bake out: 250? C maximum with cable and magnet attached
Pressure response time
< 50 milliseconds @ UHV pressures
Ignition response (starting time)
< 30 seconds @ 1 x 10-10 Torr
Operating voltage
3 kilovolts
Materials exposed to vacuum
Stainless steel, nickel, glass, nickel alloy 52
Sensitivity
2 A / Torr + 20% at 5 x 10-6 Torr

Click Here for Agilent IMG 300 Manual


A&J Vacuum Services offers full repair/service of Agilent, along with all other brands offered on our website. AJVS also services Agilent pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.