The Pfeiffer Adixen ASM 182/192 series includes the latest evolutions of Adixen leak detectors, of which thousands are utilized in successful daily operation throughout the world in various applications and industries, including the automotive, chemical and mechanical, and electrical, electronics and packaging industries. A standout product of this series is the Adixen ASM 182 TD+ helium leak detector, utilized extensively in quality control purposes and maintenance of semiconductor processing systems, as well as quality control of vacuum components. Additionally, it is utilized as a blister-testing appliance within the pharmaceutical industry. This brand of Pfeiffer Adixen leak detectors offers several unique features, among them high sensitivity [5 x 10^(-12) mbar l/s], in addition to rapid response time while activated in spraying mode.
The Adixen ASM 182 TD+ leak detector is extremely flexible and user-friendly, with an emphasis on operational durability and ease-of-access. Automatic operation is provided throughout a vast range of processes, including atmospheric sniffer testing and refinement of extended gas lines and tubing. The ASM 182 TD+ mechanism likewise features a range of distinct operating modes, including gross leak mode and ultra-sensitive vacuum fine leak mode. Readily available basic functions, combined digital and analog display, and a range of advanced functions are also included for user convenience.
Leak detection utilizing helium has a complex history dating back to the first half of the twentieth century and is used in a variety of processes and industries. Helium is used as the preferred tracer gas for eliminating leaks for a variety of reasons, including its non-flammability, non-toxicity, and inexpensiveness relative to other gases. Likewise, its inert state and small atomic size (helium has an atomic mass unit of 4 - second only to hydrogen, which has an AMU of 2) allows the gas to pass through leaks with ease. Unlike hydrogen however, helium is stable and non-explosive, providing a better alternative to be used in leak detection processes.
Utilizing the beneficial qualities of helium, a Helium Leak Detector pumps molecules of the gas into the device's analyzer cell through the use of vacuum pumps. The analyzer cell works on the principle of mass spectroscopy and measures the gas's partial pressure, displayed on the device's spectrometer. A higher reading indicates that a leak may be present, as represented by the quantity and concentration of helium molecules that have passed through a given space, as analyzed by the device. The leak detector converts this partial pressure of molecules into a flow rate. Helium leak detectors are known to be extremely precise and exhibit unparalleled accuracy in detecting leaks.
Click Here for Pfeiffer/Adixen ASM 182 TD+ Manual
A&J Vacuum offers full service and repair of Pfeiffer ASM 182 TD+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer Vacuum turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Backing Pump | Oil-Free Backing Pump |
Backing Pump Capacity | 25 m³/h | 14.71 cfm | 416.67 l/min |
Detectable Gases | 4He |
Dimensions (L x W x H) | 601 x 487 x 456 mm | 23.66 x 19.17 x 17.95 inch |
Flange Model (Inlet) | DN 40 ISO-KF |
I/O interfaces | Digital inputs (Start, Vent, Calibration…); Digital outputs (Test modes, cycle in progress, helium signal above reject set point…); Analog outputs (Helium signal log, Inlet pressure) |
Language | English |
Mains Cable | Yes, US power cable |
Minimum Detectable Leak Rate for Helium (Sniffing Leak Detection) | 1 * 10^[-8] Pa m3/s | 7.5 * 10^[-8] Torr l/s | 1 * 10^[-7] mbar l/s |
Minimum Detectable Leak Rate for Helium (Vacuum Leak Detection) | 5 * 10^[-13] Pa m³/s |
Noise Level | 65 dB(A) |
Power Consumption Max. | 1500 W |
Pumping Speed for He | 4.4 l/s |
Sound Pressure Level | 65 dB(A) |
Start-Up Time (20°C) With Calibration | < 5.5 min |
Start-Up Time (20°C) Without Calibration | < 4 min |
Supply | 110 – 130 V, 50/60 Hz |
Test Method | Vacuum and Sniffing Leak Detection |
Type | High Performance - Compact |
User Interface | Basic User Interface |
Weight | 88 kg | 194 lb |
Click Here for Pfeiffer/Adixen ASM 182 TD+ Manual
A&J Vacuum offers full service and repair of Pfeiffer ASM 182 TD+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer Vacuum turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
The Pfeiffer Adixen ASM 182/192 series includes the latest evolutions of Adixen leak detectors, of which thousands are utilized in successful daily operation throughout the world in various applications and industries, including the automotive, chemical and mechanical, and electrical, electronics and packaging industries. A standout product of this series is the Adixen ASM 182 TD+ helium leak detector, utilized extensively in quality control purposes and maintenance of semiconductor processing systems, as well as quality control of vacuum components. Additionally, it is utilized as a blister-testing appliance within the pharmaceutical industry. This brand of Pfeiffer Adixen leak detectors offers several unique features, among them high sensitivity [5 x 10^(-12) mbar l/s], in addition to rapid response time while activated in spraying mode.
The Adixen ASM 182 TD+ leak detector is extremely flexible and user-friendly, with an emphasis on operational durability and ease-of-access. Automatic operation is provided throughout a vast range of processes, including atmospheric sniffer testing and refinement of extended gas lines and tubing. The ASM 182 TD+ mechanism likewise features a range of distinct operating modes, including gross leak mode and ultra-sensitive vacuum fine leak mode. Readily available basic functions, combined digital and analog display, and a range of advanced functions are also included for user convenience.
Leak detection utilizing helium has a complex history dating back to the first half of the twentieth century and is used in a variety of processes and industries. Helium is used as the preferred tracer gas for eliminating leaks for a variety of reasons, including its non-flammability, non-toxicity, and inexpensiveness relative to other gases. Likewise, its inert state and small atomic size (helium has an atomic mass unit of 4 - second only to hydrogen, which has an AMU of 2) allows the gas to pass through leaks with ease. Unlike hydrogen however, helium is stable and non-explosive, providing a better alternative to be used in leak detection processes.
Utilizing the beneficial qualities of helium, a Helium Leak Detector pumps molecules of the gas into the device's analyzer cell through the use of vacuum pumps. The analyzer cell works on the principle of mass spectroscopy and measures the gas's partial pressure, displayed on the device's spectrometer. A higher reading indicates that a leak may be present, as represented by the quantity and concentration of helium molecules that have passed through a given space, as analyzed by the device. The leak detector converts this partial pressure of molecules into a flow rate. Helium leak detectors are known to be extremely precise and exhibit unparalleled accuracy in detecting leaks.
Click Here for Pfeiffer/Adixen ASM 182 TD+ Manual
A&J Vacuum offers full service and repair of Pfeiffer ASM 182 TD+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer Vacuum turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Backing Pump | Oil-Free Backing Pump |
Backing Pump Capacity | 25 m³/h | 14.71 cfm | 416.67 l/min |
Detectable Gases | 4He |
Dimensions (L x W x H) | 601 x 487 x 456 mm | 23.66 x 19.17 x 17.95 inch |
Flange Model (Inlet) | DN 40 ISO-KF |
I/O interfaces | Digital inputs (Start, Vent, Calibration…); Digital outputs (Test modes, cycle in progress, helium signal above reject set point…); Analog outputs (Helium signal log, Inlet pressure) |
Language | English |
Mains Cable | Yes, US power cable |
Minimum Detectable Leak Rate for Helium (Sniffing Leak Detection) | 1 * 10^[-8] Pa m3/s | 7.5 * 10^[-8] Torr l/s | 1 * 10^[-7] mbar l/s |
Minimum Detectable Leak Rate for Helium (Vacuum Leak Detection) | 5 * 10^[-13] Pa m³/s |
Noise Level | 65 dB(A) |
Power Consumption Max. | 1500 W |
Pumping Speed for He | 4.4 l/s |
Sound Pressure Level | 65 dB(A) |
Start-Up Time (20°C) With Calibration | < 5.5 min |
Start-Up Time (20°C) Without Calibration | < 4 min |
Supply | 110 – 130 V, 50/60 Hz |
Test Method | Vacuum and Sniffing Leak Detection |
Type | High Performance - Compact |
User Interface | Basic User Interface |
Weight | 88 kg | 194 lb |
Click Here for Pfeiffer/Adixen ASM 182 TD+ Manual
A&J Vacuum offers full service and repair of Pfeiffer ASM 182 TD+ Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer Vacuum turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.