Filament for Alcatel Adixen Helium Leak Detectors models ASM 10, ASM 50, ASM 51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T Leak Detectors, 053146
Item#: PN17513 Mfr Part#: 053146 Manufacturer: Pfeiffer Vacuum
Condition: New
New Alcatel Adixen Helium Leak Detector Filament for ASM 10, ASM 50, ASM 51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T Leak Detectors, 053146

Features:

PRICE: $569.00
WEB SAVINGS: $74.00
YOU PAY: $495.00
Item#: PN17513 Mfr Part#: 053146
Filament for Alcatel Adixen Helium Leak Detectors models ASM 10, ASM 50, ASM 51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T Leak Detectors, 053146
Item#: PN17513 Mfr Part#: 053146 Manufacturer: Pfeiffer Vacuum

Alcatel Adixen Helium Leak Detector Filament for ASM 10, ASM 50, ASM  51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T Leak Detectors, 053146

 

Filament Overview:


Alcatel Adixen Helium Leak Detector Filament is compatible with the following leak detectors:

  • ASM 10
  • ASM 50
  • ASM 51
  • ASM 110
  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 181 TD+​
  • ASM 182
This item is non-returnable/non-refundable

Alcatel Adixen Helium Leak Detector Filament for ASM 10, ASM 50, ASM  51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T  Leak Detectors, 053146

 

Filament Overview:


Alcatel Adixen Helium Leak Detector Filament is compatible with the following leak detectors:

  • ASM 10
  • ASM 50
  • ASM 51
  • ASM 110
  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 180
  • ASM 181 TD+​
  • ASM 182
  • ASM 192 T
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Filament for Alcatel Adixen Helium Leak Detectors models ASM 10, ASM 50, ASM 51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T Leak Detectors, 053146
Item#: PN17513 Mfr Part#: 053146 Manufacturer: Pfeiffer Vacuum

Alcatel Adixen Helium Leak Detector Filament for ASM 10, ASM 50, ASM  51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T Leak Detectors, 053146

 

Filament Overview:


Alcatel Adixen Helium Leak Detector Filament is compatible with the following leak detectors:

  • ASM 10
  • ASM 50
  • ASM 51
  • ASM 110
  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 181 TD+​
  • ASM 182

Alcatel Adixen Helium Leak Detector Filament for ASM 10, ASM 50, ASM  51, ASM 110, ASM 142, ASM 150, ASM 151, ASM 180, 181 TD+, ASM 182, ASM 192 T  Leak Detectors, 053146

 

Filament Overview:


Alcatel Adixen Helium Leak Detector Filament is compatible with the following leak detectors:

  • ASM 10
  • ASM 50
  • ASM 51
  • ASM 110
  • ASM 142
  • ASM 150
  • ASM 151
  • ASM 180
  • ASM 181 TD+​
  • ASM 182
  • ASM 192 T
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST