Agilent G2589-80062 Turbo Pump, DN 100 ISOK Inlet Flange, G258980062
Item#: PN17593 Mfr Part#: G258980062 Manufacturer: Edwards Vacuum
Condition: Remanufactured In Stock
Remanufactured Agilent Technologies G2589-80062 Turbo Vacuum Pump, DN 100 ISOK Inlet Flange

Features:
  • DN 100 ISO Inlet Flange
  • DN 25 KF ports
  • Inlet Pumping Speed (l x s-1): N2: 220
  • Compression Ratio: N2: >1 x 108

PRICE: $6,950.00
WEB SAVINGS: $1,125.00
YOU PAY: $5,825.00
Item#: PN17593 Mfr Part#: G258980062
Agilent G2589-80062 Turbo Pump, DN 100 ISOK Inlet Flange, G258980062
Item#: PN17593 Mfr Part#: G258980062 Manufacturer: Edwards Vacuum

Remanufactured Agilent G2589-80062 Turbo Pump, DN 100 ISOK Inlet Flange, G258980062


The Agilent G2589-80062 turbomolecular pump is made from a multi-stage axial-flow turbine which is optimised for operation in molecular flow conditions. The drag pump is made from pumping channels formed by helical grooves. The drag pump is designed for operation at higher pressures than conventional turbomolecular pumps.

Agilent G258980062 is also known as Edwards EXT255 / B75304000 Turbo Pump

The light alloy rotor is machined from one piece to form the angled blades of the turbomolecular pump. The rotor blades rotate between angled stator blades which are supported by spacer rings. The rotor and stator blades have an open structure at the pump inlet, and a more closed structure at the outlet. This configuration gives an optimum combination of pumping speed and compression when pumping gases of both high and low molecular weight. For the blades to be effective, their speed must be close to the thermal velocity of the gas. The rotor therefore rotates at up to 60000 r min-1.

Gas from the inlet is compressed through each of the bladed stages of the turbomolecular pump and transferred to the drag pump. In the drag pump stages, the gas is further compressed as it is pumped around the channels formed by the helical grooves.

The rotating assembly is supported at the inlet end by a frictionless magnetic bearing and by a precision ceramic ball bearing at the outlet end. The ball bearing is lubricated from an oil reservoir and wick mechanism.

All of the pumps are supplied with an inlet-screen fitted in the bore of the inlet-flange. The EXT255Hi pumps are also supplied with an inlet-strainer which fits in the interstage-port. The inlet-screen and inlet-strainer protect the pump against damage which would be caused by debris which enters the pump. The inlet-screen also protects you from the sharp blades in the pump.

All of the pumps have a vent-port you can use to vent the pump and your vacuum system to atmospheric pressure. The vent-port introduces vent gas part way up the pump rotor; this ensures maximum cleanliness. The pump is supplied with a manual vent-valve fitted to the vent-port.

All of the pumps have a purge-port in the motor and bearing housing chamber. In order to protect the bearing lubricant from the effects of high oxygen concentrations, you can introduce an inert purge gas through the purge-port. You can fit an optional vent-port adaptor and purge restrictor to the purge-port to control the flow rate of the purge gas and to filter the gas supply.


A&J Vacuum Repair / Rebuild and Service Agilent Edwards G2589-80062 Turbo Pumps, Agillent Scroll Pumps  and  all Vacuum pump service along with all other Edwards Vacuum Rotary Vane Pumps, Edwards Turbomolecular Pumps  repair, Edwards Leak Detector Repair and all other Edwards Vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Remanufactured Agilent G2589-80062 Turbo Pump, DN 100 ISOK Inlet Flange, G258980062


Inlet Pumping Speed (l x s-1): N2: 220
  He: 230
  H2: 180
Compression Ratio: N2: >1 x 108
  He: 2.5 x 105
  H2: 1.1 x 104
Ultimate Pressure (mbar): <5 x 10-9

A&J Vacuum Repair / Rebuild and Service Agilent Edwards G2589-80062 Turbo Pumps, Agillent Scroll Pumps  and  all Vacuum pump service along with all other Edwards Vacuum Rotary Vane Pumps, Edwards Turbomolecular Pumps  repair, Edwards Leak Detector Repair and all other Edwards Vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Agilent G2589-80062 Turbo Pump, DN 100 ISOK Inlet Flange, G258980062
Item#: PN17593 Mfr Part#: G258980062 Manufacturer: Edwards Vacuum

Remanufactured Agilent G2589-80062 Turbo Pump, DN 100 ISOK Inlet Flange, G258980062


The Agilent G2589-80062 turbomolecular pump is made from a multi-stage axial-flow turbine which is optimised for operation in molecular flow conditions. The drag pump is made from pumping channels formed by helical grooves. The drag pump is designed for operation at higher pressures than conventional turbomolecular pumps.

Agilent G258980062 is also known as Edwards EXT255 / B75304000 Turbo Pump

The light alloy rotor is machined from one piece to form the angled blades of the turbomolecular pump. The rotor blades rotate between angled stator blades which are supported by spacer rings. The rotor and stator blades have an open structure at the pump inlet, and a more closed structure at the outlet. This configuration gives an optimum combination of pumping speed and compression when pumping gases of both high and low molecular weight. For the blades to be effective, their speed must be close to the thermal velocity of the gas. The rotor therefore rotates at up to 60000 r min-1.

Gas from the inlet is compressed through each of the bladed stages of the turbomolecular pump and transferred to the drag pump. In the drag pump stages, the gas is further compressed as it is pumped around the channels formed by the helical grooves.

The rotating assembly is supported at the inlet end by a frictionless magnetic bearing and by a precision ceramic ball bearing at the outlet end. The ball bearing is lubricated from an oil reservoir and wick mechanism.

All of the pumps are supplied with an inlet-screen fitted in the bore of the inlet-flange. The EXT255Hi pumps are also supplied with an inlet-strainer which fits in the interstage-port. The inlet-screen and inlet-strainer protect the pump against damage which would be caused by debris which enters the pump. The inlet-screen also protects you from the sharp blades in the pump.

All of the pumps have a vent-port you can use to vent the pump and your vacuum system to atmospheric pressure. The vent-port introduces vent gas part way up the pump rotor; this ensures maximum cleanliness. The pump is supplied with a manual vent-valve fitted to the vent-port.

All of the pumps have a purge-port in the motor and bearing housing chamber. In order to protect the bearing lubricant from the effects of high oxygen concentrations, you can introduce an inert purge gas through the purge-port. You can fit an optional vent-port adaptor and purge restrictor to the purge-port to control the flow rate of the purge gas and to filter the gas supply.


A&J Vacuum Repair / Rebuild and Service Agilent Edwards G2589-80062 Turbo Pumps, Agillent Scroll Pumps  and  all Vacuum pump service along with all other Edwards Vacuum Rotary Vane Pumps, Edwards Turbomolecular Pumps  repair, Edwards Leak Detector Repair and all other Edwards Vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Remanufactured Agilent G2589-80062 Turbo Pump, DN 100 ISOK Inlet Flange, G258980062


Inlet Pumping Speed (l x s-1): N2: 220
  He: 230
  H2: 180
Compression Ratio: N2: >1 x 108
  He: 2.5 x 105
  H2: 1.1 x 104
Ultimate Pressure (mbar): <5 x 10-9

A&J Vacuum Repair / Rebuild and Service Agilent Edwards G2589-80062 Turbo Pumps, Agillent Scroll Pumps  and  all Vacuum pump service along with all other Edwards Vacuum Rotary Vane Pumps, Edwards Turbomolecular Pumps  repair, Edwards Leak Detector Repair and all other Edwards Vacuum pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.