The electronic drive unit TC 1200 is an integrated component of the turbopump. It's purpose is to drive, monitor and control the entire pump.
To correctly identify the product when communicating with Pfeiffer Vacuum, always have the information from the rating plate available.
A Pfeiffer Vacuum display and control panel (DCU or HPU) or an external PC can be connected to the electronic drive unit via the connection designated "RS-485". The interface is electrically isolated from the maximum supply voltage of the electronic drive unit. The electrical couplings are optically decoupled internally.
THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.
Click Here for Pfeiffer Vacuum TC 1200 Manual
A&J Vacuum repair / rebuild and service Pfeiffer HiPace Turbo Pumps, Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
Click Here for Pfeiffer Vacuum TC 1200 Manual
A&J Vacuum repair / rebuild and service Pfeiffer HiPace Turbo Pumps, Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
The electronic drive unit TC 1200 is an integrated component of the turbopump. It's purpose is to drive, monitor and control the entire pump.
To correctly identify the product when communicating with Pfeiffer Vacuum, always have the information from the rating plate available.
A Pfeiffer Vacuum display and control panel (DCU or HPU) or an external PC can be connected to the electronic drive unit via the connection designated "RS-485". The interface is electrically isolated from the maximum supply voltage of the electronic drive unit. The electrical couplings are optically decoupled internally.
THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.
Click Here for Pfeiffer Vacuum TC 1200 Manual
A&J Vacuum repair / rebuild and service Pfeiffer HiPace Turbo Pumps, Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
Click Here for Pfeiffer Vacuum TC 1200 Manual
A&J Vacuum repair / rebuild and service Pfeiffer HiPace Turbo Pumps, Pfeiffer Backing Pumps along with all other Pfeiffer Vacuum Pumps and all other Pfeiffer Leak Detector Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.