Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000, EXDC 160
Item#: PN18583 Mfr Part#: D39641000 Manufacturer: Edwards Vacuum
Condition: Remanufactured In Stock
Remanufactured Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000

Features:

PRICE: $1,431.00
WEB SAVINGS: $556.00
YOU PAY: $875.00
Item#: PN18583 Mfr Part#: D39641000
Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000, EXDC 160
Item#: PN18583 Mfr Part#: D39641000 Manufacturer: Edwards Vacuum

Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000, EXDC 160 Turbo Pump Drive Module.

 

The Edwards EXDC160 Turbo Pump Controller generates the control signals necessary to operate an EXT pump and its accessories.

The EXDC has no manual controls and can only be operated through the logic interface. To operate the EXT pump, you must therefore connect the EXDC to your own control equipment and electrical supply.

This Controller is designed for the following Mass Spectrometer Turbo Pumps:

  • Edwards EXT 70 Turbo Pump
  • Edwards EXT 70H Turbo Pump
  • Edwards EXT 250 Turbo Pump
  • Edwards EXT 255H Turbo Pump

 

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000, EXDC 160 Turbo Pump Drive Module.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000, EXDC 160
Item#: PN18583 Mfr Part#: D39641000 Manufacturer: Edwards Vacuum

Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000, EXDC 160 Turbo Pump Drive Module.

 

The Edwards EXDC160 Turbo Pump Controller generates the control signals necessary to operate an EXT pump and its accessories.

The EXDC has no manual controls and can only be operated through the logic interface. To operate the EXT pump, you must therefore connect the EXDC to your own control equipment and electrical supply.

This Controller is designed for the following Mass Spectrometer Turbo Pumps:

  • Edwards EXT 70 Turbo Pump
  • Edwards EXT 70H Turbo Pump
  • Edwards EXT 250 Turbo Pump
  • Edwards EXT 255H Turbo Pump

 

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

Edwards EXDC160 Turbo Pump Controller, 70-80V, 107W, D39641000, EXDC 160 Turbo Pump Drive Module.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.