Edwards AIM XL DN40CF Inverted Magnetron Gauge, D14665000
Item#: PN19710 Mfr Part#: D14665000 Manufacturer: Edwards Vacuum
Condition: New
New Edwards Inverted Magnetron Gauge AIM XL DN40CF (AIMXLDN40CF), AIM-XL-DN40CF, D14665000, Low magnetic field version - XL - for sensitive applications, e.g. mass spectrometry and electron microscopy.

Features:
  • Pressure range 1 x 10-2 to 1 x 10-9 mbar
  • Compatible with all of Edwards Active Gauge Controllers
  • Operating Temperature; +5 to +60 *C
  • Interchangeable body

PRICE: $2,500.00
WEB SAVINGS: $214.00
YOU PAY: $2,286.00
Item#: PN19710 Mfr Part#: D14665000
Edwards AIM XL DN40CF Inverted Magnetron Gauge, D14665000
Item#: PN19710 Mfr Part#: D14665000 Manufacturer: Edwards Vacuum

Edwards Inverted Magnetron Gauge AIM XL DN40CF (AIMXLDN40CF), AIM-XL-DN40CF, D14665000

 

Edwards AIM XL DN40 CF Overview:


The Edwards AIM Active Inverted Magnetron Gauges (AIM) combine the gauge-head and controller in one compact Active AIM XL unit. Low Magnetic field version XL for sensitive applications. These gauges have proved to be rugged and reliable in a wide range of applications ranging from scientific instruments to industrial processes.

This gauge has a low external magnetic field making it suitable for use with sensitive analytical instruments or maglev turbo pumps. In addition, this gauge features a linear output for easy integration with a computer or PLC.

Technology

The Edwards AIM-XL-DN40CF Gauge is an inverted magnetron gauge head and gauge controller in a single compact unit. The gauge operates as a cold cathode ionisation gauge, in which pressure is measured indirectly as a function of the current that flows in a Townsend discharge maintained in the body tube.

The measurement range of the AIM-XL-DN40CF Gauge is 1 x 10-9 to 1 x 10-2 mbar.

The Edwards AIM Gauge requires a 13.5 to 36 V d.c. power supply: it has a 2 to 10 V d.c. analogue output which is related to pressure.

The AIM-XL-DN40CF Gauge is compatible with all of Edwards Active Gauge Controllers and with the appropriate versions of the Active Gauge Displays. Alternatively you can use an independent power supply for the AIM Gauge and you can read the AIM Gauge output signal with a voltmeter or an analogue-to-digital converter.

Applications

All vacuum applications requiring rugged and reliable pressure indication in the range 1 x 10-2 to 1 x 10-9 mbar. Typical processes range from general vacuum through industrial coaters and furnaces to scientific instruments and semicon.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Edwards AIM XL DN40 CF Dimensions:


Edwards AIM S NW 25 D14641000, Edwards AIM X NW25 D14665000

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards Inverted Magnetron Gauge AIM XL DN40CF (AIMXLDN40CF), AIM-XL-DN40CF, D14665000

 

Edwards AIM XL DN40 CF Technical Data:


Pressure Range  
  AIM-X and AIM-XL 10-2 to 10-9 mbar
Accuracy* Typically ±30%
Maximum overpressure 10 bar absolute (145 psi)
  Power supply +13.5 to +36V d.c. (max 1 V ripple)
  Power consumption 2 W Maximum
  Output signal 2 to 10 V d.c.
Set point Open collector transistor
  Maximum voltage 40V d.c.
  Current 100 mA max
Temperature range  
  Operating +5 to +60°C
  Storage 0 to +70°C
  Baking (DN40CF version only) 300 o C with electronics removed DN40CF only
Materials exposed to vacuum  
  NW25 versions Stainless steel 304 & 306 & 347, fluoroelastomer, glass
  DN40CF Stainless steel (AISI 304 and 306), copper, ceramic, very small amount of copper braze
Internal volume 26 cm3
Weight 0.81 kg
AIM-X NW25 810 g
AIM-XL NW25 860 g
AIM-X DN40CF 1090 g
AIM-XL DN40CF 1140 g
External interface connector 8-way FCC68/RJ45 socket
Vacuum fitting NW25
Standards  
  Electromagnetic compatibility EN 61326 (Class B Emissions)
  Enclosure rating IP40

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Name
Price
Item#:
PN19714
Mfr Part#:
D40001010
$49.99
Item#:
PN19715
Mfr Part#:
D40001030
$89.95
Item#:
PN19716
Mfr Part#:
D40001050
$115.95
Item#:
PN19717
Mfr Part#:
D40001100
$179.00
Item#:
PN19718
Mfr Part#:
D40001150
$228.00
Item#:
PN19719
Mfr Part#:
D40001250
$305.00
Item#:
PN19720
Mfr Part#:
D40001500
$725.00
Item#:
PN19721
Mfr Part#:
D40001999
$720.00
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards AIM XL DN40CF Inverted Magnetron Gauge, D14665000
Item#: PN19710 Mfr Part#: D14665000 Manufacturer: Edwards Vacuum

Edwards Inverted Magnetron Gauge AIM XL DN40CF (AIMXLDN40CF), AIM-XL-DN40CF, D14665000

 

Edwards AIM XL DN40 CF Overview:


The Edwards AIM Active Inverted Magnetron Gauges (AIM) combine the gauge-head and controller in one compact Active AIM XL unit. Low Magnetic field version XL for sensitive applications. These gauges have proved to be rugged and reliable in a wide range of applications ranging from scientific instruments to industrial processes.

This gauge has a low external magnetic field making it suitable for use with sensitive analytical instruments or maglev turbo pumps. In addition, this gauge features a linear output for easy integration with a computer or PLC.

Technology

The Edwards AIM-XL-DN40CF Gauge is an inverted magnetron gauge head and gauge controller in a single compact unit. The gauge operates as a cold cathode ionisation gauge, in which pressure is measured indirectly as a function of the current that flows in a Townsend discharge maintained in the body tube.

The measurement range of the AIM-XL-DN40CF Gauge is 1 x 10-9 to 1 x 10-2 mbar.

The Edwards AIM Gauge requires a 13.5 to 36 V d.c. power supply: it has a 2 to 10 V d.c. analogue output which is related to pressure.

The AIM-XL-DN40CF Gauge is compatible with all of Edwards Active Gauge Controllers and with the appropriate versions of the Active Gauge Displays. Alternatively you can use an independent power supply for the AIM Gauge and you can read the AIM Gauge output signal with a voltmeter or an analogue-to-digital converter.

Applications

All vacuum applications requiring rugged and reliable pressure indication in the range 1 x 10-2 to 1 x 10-9 mbar. Typical processes range from general vacuum through industrial coaters and furnaces to scientific instruments and semicon.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Edwards AIM XL DN40 CF Dimensions:


Edwards AIM S NW 25 D14641000, Edwards AIM X NW25 D14665000

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards Inverted Magnetron Gauge AIM XL DN40CF (AIMXLDN40CF), AIM-XL-DN40CF, D14665000

 

Edwards AIM XL DN40 CF Technical Data:


Pressure Range  
  AIM-X and AIM-XL 10-2 to 10-9 mbar
Accuracy* Typically ±30%
Maximum overpressure 10 bar absolute (145 psi)
  Power supply +13.5 to +36V d.c. (max 1 V ripple)
  Power consumption 2 W Maximum
  Output signal 2 to 10 V d.c.
Set point Open collector transistor
  Maximum voltage 40V d.c.
  Current 100 mA max
Temperature range  
  Operating +5 to +60°C
  Storage 0 to +70°C
  Baking (DN40CF version only) 300 o C with electronics removed DN40CF only
Materials exposed to vacuum  
  NW25 versions Stainless steel 304 & 306 & 347, fluoroelastomer, glass
  DN40CF Stainless steel (AISI 304 and 306), copper, ceramic, very small amount of copper braze
Internal volume 26 cm3
Weight 0.81 kg
AIM-X NW25 810 g
AIM-XL NW25 860 g
AIM-X DN40CF 1090 g
AIM-XL DN40CF 1140 g
External interface connector 8-way FCC68/RJ45 socket
Vacuum fitting NW25
Standards  
  Electromagnetic compatibility EN 61326 (Class B Emissions)
  Enclosure rating IP40

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Name
Price
Item#:
PN19714
Mfr Part#:
D40001010
$49.99
Item#:
PN19715
Mfr Part#:
D40001030
$89.95
Item#:
PN19716
Mfr Part#:
D40001050
$115.95
Item#:
PN19717
Mfr Part#:
D40001100
$179.00
Item#:
PN19718
Mfr Part#:
D40001150
$228.00
Item#:
PN19719
Mfr Part#:
D40001250
$305.00
Item#:
PN19720
Mfr Part#:
D40001500
$725.00
Item#:
PN19721
Mfr Part#:
D40001999
$720.00
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.