Oerlikon / Leybold Turbo Drive TD 400 Turbo Pump Controller, RS 485, 800073V0003, Demo Unit, Like New !
Item#: PN20072 Mfr Part#: 800073V0003 Manufacturer: Leybold
Condition: Demo Ships Within 1-3 Days
Demo Oerlikon / Leybold Turbo Drive TD 400 Turbo Pump Controller, RS 485, 800073V0003, Demo Unit, Like New !

Features:

PRICE: $1,750.00
WEB SAVINGS: $400.00
YOU PAY: $1,350.00
Item#: PN20072 Mfr Part#: 800073V0003
Oerlikon / Leybold Turbo Drive TD 400 Turbo Pump Controller, RS 485, 800073V0003, Demo Unit, Like New !
Item#: PN20072 Mfr Part#: 800073V0003 Manufacturer: Leybold

Oerlikon / Leybold Turbo Drive TD 400 Turbo Pump Controller, RS 485, 800073V0003, Demo Unit, Like New !


The Oerlikon / Leybold Turbo Drive TD400 supplies power to the TW series turbo pumps and is used to control their operation.

The Turbo Drive TD-400 is suited for operation of the following pumps:

  • TURBOVAC TW 70 H
  • TURBOVAC TW 220/150 S, TW 220/150/15 S
  • TURBOVAC TW 250 S
  • TURBOVAC TW 300, TW 300 H

Other pumps may only be operated after approval from Leybold or if the operation of such pumps is expressly permitted in the Operating Instructions for the specific pump. The Turbo Drive TD 400 is either integrated in the pump or it is separate and linked to the pump by means of a connecting cable. The Turbo Drive TD 400 requires a supply voltage of 24 V DC. It is equipped with interfaces for programmable controls (REMOTE) and an optional interface for serial communication. The Turbo Drive TD 400 complies with SELV requirements (Safety Extra Low Voltage).


A&J Vacuum also repair / rebuild and service Oerlikon Turbo Drive 400 Turbo Pump controllers and TW400/300 Turbo Pumps  along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

This item is non-returnable/non-refundable

Oerlikon / Leybold Turbo Drive TD 400 Turbo Vacuum Pump Controller, RS 485, 800073V0003, Like New Demo Unit ! Never Installed


Supply Voltage: 24 V DC 5%

When Operating a TW 300, TW 300 H, TW 220/150(/15) S:

  • Maximum Power Consumption: 190 W
  • Maximum Peak Current, Input Side: 8 A DC
  • Required Power Output From The Power Supply: 200 W

When Operating a TW 70 H, TW 250 S:

  • Maximum Power Consumption: 140 W
  • Maximum Peak Current, Input Side: 6 A DC
  • Required Power Output From The Power Supply: 150 W

Load Capability, Relay Output: 42 V, 0.5 A

Weight: 0.7 kg / 1.5 lbs


A&J Vacuum also repair / rebuild and service Oerlikon Turbo Drive 400 Turbo Pump controllers and TW400/300 Turbo Pumps  along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Oerlikon / Leybold Turbo Drive TD 400 Turbo Pump Controller, RS 485, 800073V0003, Demo Unit, Like New !
Item#: PN20072 Mfr Part#: 800073V0003 Manufacturer: Leybold

Oerlikon / Leybold Turbo Drive TD 400 Turbo Pump Controller, RS 485, 800073V0003, Demo Unit, Like New !


The Oerlikon / Leybold Turbo Drive TD400 supplies power to the TW series turbo pumps and is used to control their operation.

The Turbo Drive TD-400 is suited for operation of the following pumps:

  • TURBOVAC TW 70 H
  • TURBOVAC TW 220/150 S, TW 220/150/15 S
  • TURBOVAC TW 250 S
  • TURBOVAC TW 300, TW 300 H

Other pumps may only be operated after approval from Leybold or if the operation of such pumps is expressly permitted in the Operating Instructions for the specific pump. The Turbo Drive TD 400 is either integrated in the pump or it is separate and linked to the pump by means of a connecting cable. The Turbo Drive TD 400 requires a supply voltage of 24 V DC. It is equipped with interfaces for programmable controls (REMOTE) and an optional interface for serial communication. The Turbo Drive TD 400 complies with SELV requirements (Safety Extra Low Voltage).


A&J Vacuum also repair / rebuild and service Oerlikon Turbo Drive 400 Turbo Pump controllers and TW400/300 Turbo Pumps  along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

Oerlikon / Leybold Turbo Drive TD 400 Turbo Vacuum Pump Controller, RS 485, 800073V0003, Like New Demo Unit ! Never Installed


Supply Voltage: 24 V DC 5%

When Operating a TW 300, TW 300 H, TW 220/150(/15) S:

  • Maximum Power Consumption: 190 W
  • Maximum Peak Current, Input Side: 8 A DC
  • Required Power Output From The Power Supply: 200 W

When Operating a TW 70 H, TW 250 S:

  • Maximum Power Consumption: 140 W
  • Maximum Peak Current, Input Side: 6 A DC
  • Required Power Output From The Power Supply: 150 W

Load Capability, Relay Output: 42 V, 0.5 A

Weight: 0.7 kg / 1.5 lbs


A&J Vacuum also repair / rebuild and service Oerlikon Turbo Drive 400 Turbo Pump controllers and TW400/300 Turbo Pumps  along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST