Edwards XDS 5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS5C
Item#: PN20076 Mfr Part#: A7201906 Manufacturer: Edwards Vacuum
Condition: Remanufactured Call us for Availability
Remanufactured Edwards XDS5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS-5C, XDS 5

Features:
  • Ultimate Vacuum: 9 x 10-1 mbar
  • Inlet Flange: NW 25
  • Exhaust Flange: NW 25

Price upon request
Item#: PN20076 Mfr Part#: A7201906
Edwards XDS 5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS5C
Item#: PN20076 Mfr Part#: A7201906 Manufacturer: Edwards Vacuum

Edwards XDS 5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS5C

 

Edwards XDS 5C Overview:


The Edwards XDS 5C Pumps are an innovative design which use a bearing shield to isolate the vacuum environment from all forms of lubricant, not only making it totally dry, but hermetically sealed. The shield also protects the bearing from any process vapors.

Edwards XDS 5C Gas ballast allows vapor to be handled and opens up the range of applications to many that were previously unsuited to scroll pumps.

The XDS5C scroll pump is designed for pumping condensable vapors and uses materials selected for a wide range of laboratory wet chemistry applications.

  • XDS 5C Lubricant-free within the vacuum envelope and hermetically sealed means totally clean and dry vacuum to prevent cross contamination
  • No atmosphere to vacuum shaft seals means bearing are completely isolated, which prevents process attack and means the bearings run cooler and last longer
  • Simple single sided scroll design means routine maintenance is done in minutes for low cost of ownership and maximum up-time
  • No oil changes required eliminating costs of contaminated oil disposal
  • Gas ballast feature to enable pumping of vapors

 

Edwards XDS 5C Characteristic:


Edwards XDS5C Characteristic, A72501906

 

Edwards XDS 5C Dimensions:


Edwards XDS5C Dimensions, A72501906


A&J Vacuum repair / rebuild and service all Edwards XDS5C, XDS10C, XDS35i Scroll Vacuum Pumps, Edwards Tip Seal replacement,  along with all other Edwards Turbo Pumps, Edwards Dry 35i Pumps, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

This item is non-returnable/non-refundable

Edwards XDS 5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS5C

 

Edwards XDS 5C Technical Data:


Rotational Speed (50 Hz / 60 Hz): 1440 rpm / 1730 rpm
Ultimate Vacuum: 9 x 10-1 mbar / 90 Pa
Inlet Flange: NW 25
Exhaust Flange:  NW 25
Weight: 23 kg / 51 lbs

A&J Vacuum repair / rebuild and service all Edwards XDS5C, XDS10C, XDS35i Scroll Vacuum Pumps, Edwards Tip Seal replacement,  along with all other Edwards Turbo Pumps, Edwards Dry 35i Pumps, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards XDS 5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS5C
Item#: PN20076 Mfr Part#: A7201906 Manufacturer: Edwards Vacuum

Edwards XDS 5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS5C

 

Edwards XDS 5C Overview:


The Edwards XDS 5C Pumps are an innovative design which use a bearing shield to isolate the vacuum environment from all forms of lubricant, not only making it totally dry, but hermetically sealed. The shield also protects the bearing from any process vapors.

Edwards XDS 5C Gas ballast allows vapor to be handled and opens up the range of applications to many that were previously unsuited to scroll pumps.

The XDS5C scroll pump is designed for pumping condensable vapors and uses materials selected for a wide range of laboratory wet chemistry applications.

  • XDS 5C Lubricant-free within the vacuum envelope and hermetically sealed means totally clean and dry vacuum to prevent cross contamination
  • No atmosphere to vacuum shaft seals means bearing are completely isolated, which prevents process attack and means the bearings run cooler and last longer
  • Simple single sided scroll design means routine maintenance is done in minutes for low cost of ownership and maximum up-time
  • No oil changes required eliminating costs of contaminated oil disposal
  • Gas ballast feature to enable pumping of vapors

 

Edwards XDS 5C Characteristic:


Edwards XDS5C Characteristic, A72501906

 

Edwards XDS 5C Dimensions:


Edwards XDS5C Dimensions, A72501906


A&J Vacuum repair / rebuild and service all Edwards XDS5C, XDS10C, XDS35i Scroll Vacuum Pumps, Edwards Tip Seal replacement,  along with all other Edwards Turbo Pumps, Edwards Dry 35i Pumps, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Edwards XDS 5C Scroll Dry Pump Corrosive Application 100 / 200 V, Single Phase, A72501906, XDS5C

 

Edwards XDS 5C Technical Data:


Rotational Speed (50 Hz / 60 Hz): 1440 rpm / 1730 rpm
Ultimate Vacuum: 9 x 10-1 mbar / 90 Pa
Inlet Flange: NW 25
Exhaust Flange:  NW 25
Weight: 23 kg / 51 lbs

A&J Vacuum repair / rebuild and service all Edwards XDS5C, XDS10C, XDS35i Scroll Vacuum Pumps, Edwards Tip Seal replacement,  along with all other Edwards Turbo Pumps, Edwards Dry 35i Pumps, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.