Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, Edwards WRG, D147-01-000
Item#: PN20169 Mfr Part#: D14701000 / D147-01-000 Manufacturer: Edwards Vacuum
Condition: New In Stock
New Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, EDWARDS WRG, D147-01-000

Features:
  • Pressure range Atmosphere to 10-9 mbar/torr
  • Maximum overpressure; 6 bar absolute (145 psi)
  • Operating Temperature; +5 to +60 *C
  • Interchangeable body

PRICE: $2,950.00
WEB SAVINGS: $200.00
YOU PAY: $2,750.00
Item#: PN20169 Mfr Part#: D14701000 / D147-01-000
Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, Edwards WRG, D147-01-000
Item#: PN20169 Mfr Part#: D14701000 / D147-01-000 Manufacturer: Edwards Vacuum

Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, EDWARDS WRG D147-01-000

 

Edwards WRG-S NW25 Overview:


The Edwards WRG-S-NW 25 Wide Range Gauge family offers the capability of single port pressure measurement in the range from atmosphere to 10-9 mbar with a linear output. WRG Gauge P/N D14701000 Its a compact solution, halving the space and connectivity hardware requirement, which can be all important in many applications.

The Edwards WRG Vacuum Gauge has many advanced features, including a new patented striker, easy pushbutton calibration and set point controls and comprehensive diagnostics.

The Edwards WRG Gauge is a low maintenance and cost effective vacuum management solution when used either with a Edwards Gauge controller or directly integrated into the vacuum system controls.

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Edwards WRG-S NW25 Technology:


The Edwards WRG vacuum gauge has two gauges built in one, using Pirani technology for the upper pressure ranges, with a seamless switch over to an inverted magnetron for the lower range.

For ease of operation and more accurate pressure reading, the vacuum setting of the Edwards Pirani gauge is set automatically, while a single pushbutton sets atmospheric pressure. The Edwards WRG-S-NW25 has an easy to program set-point which operates over the entire measurement range.

The Edwards WRG magnetron Gauge uses an advanced technique for highly reliable striking, even at high vacuum or in relatively contaminated conditions. To optimize the lifetime of the gauge, the magnetron HT voltage is reduced after ignition and the magnetron operates with a low discharge current.


The Edwards WRG-S-NW25 meets EMC requirements for both light industrial emissions and heavy industrial immunity.

 

Edwards WRG-S NW25 Features:

  • Microprocessor signal processing gives seamless transition between Pirani and magnetron outputs as well as linear output (log pressure scale)
  • D-type version including cable strain relief and enhanced ingress protection - IP44
  • Low magnetic field version (SL) available for sensitive applications e.g. mass spectrometry and electron microscopy
  • Easily programmed set point covering entire measuring range
  • Magnetron uses an advanced patented technique for highly reliable striking, even at high vacuum or in relatively contaminated conditions
  • Automatic vacuum setting of Pirani gauge element
  • Single push button atmosphere setting
  • Extended service intervals and gauge lifetime, through reduction of HT voltage after ignition and low discharge current
  • Ultra compact, featuring recessed electrical connector
  • Easy service; both Pirani and magnetron elements are individually replaceable
  • Comprehensive failure mode diagnostics facility

 

Edwards WRG-S NW25 Dimensions:


Edwards WRG-S NW25, D14701000

 

Click here for Edwards WRG-S-NW25 Operation Manual D14701000

Click here for Edwards WRG Series Broshure

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

This item is non-returnable/non-refundable

Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, EDWARDS WRG, D147-01-000

 

Edwards WRG-S NW25 Overview:


Pressure range Atmosphere to 10-9 mbar/Torr
Accuracy * Typically ±15% <100 mbar and ±30%<10-3mbar
Maximum over pressure 6 bar absolute (87 psia)
Power supply +14.5 to +36 V d.c.
Power consumption 2 W maximum
Output signal 1.8 to 10.2 V d.c.
Adjustments Atmosphere and setpoint
Set point Open collector transistor
Maximum voltage 40 V d.c.
Current 100 mA maximum
Temperature range  
Operating +5 to +60 oC
Storage 0 to +70 oC
Materials exposed to vacuum (Both NW and CF versions) Stainless steel (AISI 304, 316, 321, 347), Fluoroelastomer, soda lime glass, Tungsten, trace of Nickel and Nickel Iron
Internal volume 26 cm3
Weight 0.8 kg
External interface connector 8-way FCC68 / RJ45 Socket
Interface cables Use range of active gauge cables
Standards  
Electromagnetic compatibility EN 61326 Industrial Location, Class B emissions
Enclosure rating IP40
Pin allocation **  
1. Power supply positive 5. Signal common
2. Power supply common 6. Set-point output
3. Gauge output 7. Atmosphere calibration
4. Gauge identification 8. Not connected

 

 

Click here for Edwards WRG-S-NW25 Operation Manual D14701000

Click here for Edwards WRG Series Broshure

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Name
Price
Item#:
PN19714
Mfr Part#:
D40001010
$49.99
Item#:
PN19715
Mfr Part#:
D40001030
$89.95
Item#:
PN19716
Mfr Part#:
D40001050
$115.95
Item#:
PN19717
Mfr Part#:
D40001100
$179.00
Item#:
PN19718
Mfr Part#:
D40001150
$228.00
Item#:
PN19719
Mfr Part#:
D40001250
$305.00
Item#:
PN19720
Mfr Part#:
D40001500
$725.00
Item#:
PN19721
Mfr Part#:
D40001999
$720.00
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, Edwards WRG, D147-01-000
Item#: PN20169 Mfr Part#: D14701000 / D147-01-000 Manufacturer: Edwards Vacuum

Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, EDWARDS WRG D147-01-000

 

Edwards WRG-S NW25 Overview:


The Edwards WRG-S-NW 25 Wide Range Gauge family offers the capability of single port pressure measurement in the range from atmosphere to 10-9 mbar with a linear output. WRG Gauge P/N D14701000 Its a compact solution, halving the space and connectivity hardware requirement, which can be all important in many applications.

The Edwards WRG Vacuum Gauge has many advanced features, including a new patented striker, easy pushbutton calibration and set point controls and comprehensive diagnostics.

The Edwards WRG Gauge is a low maintenance and cost effective vacuum management solution when used either with a Edwards Gauge controller or directly integrated into the vacuum system controls.

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Edwards WRG-S NW25 Technology:


The Edwards WRG vacuum gauge has two gauges built in one, using Pirani technology for the upper pressure ranges, with a seamless switch over to an inverted magnetron for the lower range.

For ease of operation and more accurate pressure reading, the vacuum setting of the Edwards Pirani gauge is set automatically, while a single pushbutton sets atmospheric pressure. The Edwards WRG-S-NW25 has an easy to program set-point which operates over the entire measurement range.

The Edwards WRG magnetron Gauge uses an advanced technique for highly reliable striking, even at high vacuum or in relatively contaminated conditions. To optimize the lifetime of the gauge, the magnetron HT voltage is reduced after ignition and the magnetron operates with a low discharge current.


The Edwards WRG-S-NW25 meets EMC requirements for both light industrial emissions and heavy industrial immunity.

 

Edwards WRG-S NW25 Features:

  • Microprocessor signal processing gives seamless transition between Pirani and magnetron outputs as well as linear output (log pressure scale)
  • D-type version including cable strain relief and enhanced ingress protection - IP44
  • Low magnetic field version (SL) available for sensitive applications e.g. mass spectrometry and electron microscopy
  • Easily programmed set point covering entire measuring range
  • Magnetron uses an advanced patented technique for highly reliable striking, even at high vacuum or in relatively contaminated conditions
  • Automatic vacuum setting of Pirani gauge element
  • Single push button atmosphere setting
  • Extended service intervals and gauge lifetime, through reduction of HT voltage after ignition and low discharge current
  • Ultra compact, featuring recessed electrical connector
  • Easy service; both Pirani and magnetron elements are individually replaceable
  • Comprehensive failure mode diagnostics facility

 

Edwards WRG-S NW25 Dimensions:


Edwards WRG-S NW25, D14701000

 

Click here for Edwards WRG-S-NW25 Operation Manual D14701000

Click here for Edwards WRG Series Broshure

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards WRG-S-NW 25 Wide Range Gauge, D14701000, EDWARDS WRG, D147-01-000

 

Edwards WRG-S NW25 Overview:


Pressure range Atmosphere to 10-9 mbar/Torr
Accuracy * Typically ±15% <100 mbar and ±30%<10-3mbar
Maximum over pressure 6 bar absolute (87 psia)
Power supply +14.5 to +36 V d.c.
Power consumption 2 W maximum
Output signal 1.8 to 10.2 V d.c.
Adjustments Atmosphere and setpoint
Set point Open collector transistor
Maximum voltage 40 V d.c.
Current 100 mA maximum
Temperature range  
Operating +5 to +60 oC
Storage 0 to +70 oC
Materials exposed to vacuum (Both NW and CF versions) Stainless steel (AISI 304, 316, 321, 347), Fluoroelastomer, soda lime glass, Tungsten, trace of Nickel and Nickel Iron
Internal volume 26 cm3
Weight 0.8 kg
External interface connector 8-way FCC68 / RJ45 Socket
Interface cables Use range of active gauge cables
Standards  
Electromagnetic compatibility EN 61326 Industrial Location, Class B emissions
Enclosure rating IP40
Pin allocation **  
1. Power supply positive 5. Signal common
2. Power supply common 6. Set-point output
3. Gauge output 7. Atmosphere calibration
4. Gauge identification 8. Not connected

 

 

Click here for Edwards WRG-S-NW25 Operation Manual D14701000

Click here for Edwards WRG Series Broshure

 


A&J Vacuum services and repairs Edwards Vacuum Measurement Transmitters, along with all other Edwards Vacuum and Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

Name
Price
Item#:
PN19714
Mfr Part#:
D40001010
$49.99
Item#:
PN19715
Mfr Part#:
D40001030
$89.95
Item#:
PN19716
Mfr Part#:
D40001050
$115.95
Item#:
PN19717
Mfr Part#:
D40001100
$179.00
Item#:
PN19718
Mfr Part#:
D40001150
$228.00
Item#:
PN19719
Mfr Part#:
D40001250
$305.00
Item#:
PN19720
Mfr Part#:
D40001500
$725.00
Item#:
PN19721
Mfr Part#:
D40001999
$720.00
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.