phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Pfeiffer HiCube 80 Eco Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267
Item#: PN20188 Mfr Part#: PM 183 255-T / PM183255-T / 2000017267 Manufacturer: Pfeiffer Vacuum
Condition: New In Stock
New Pfeiffer HiCube 80 Eco Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267

Features:
  • Inlet flange: DN 63 CF-F
  • Pumping speed : 67 l/s
  • Ultimate pressure: < 1 x 10-7 mbar
  • MVP 015 Diaphragm pump

PRICE: $13,100.00
WEB SAVINGS: $2,905.00
YOU PAY: $10,195.00
Item#: PN20188 Mfr Part#: PM 183 255-T / PM183255-T / 2000017267
Pfeiffer HiCube 80 Eco Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267
Item#: PN20188 Mfr Part#: PM 183 255-T / PM183255-T / 2000017267 Manufacturer: Pfeiffer Vacuum

Pfeiffer Hicube 80 Eco Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 PKT05100 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267, PFEIFFER HICUBE80 ECO Gauge Package

 

Pfeiffer HiCube 80 Eco Overview


The Pfeiffer Vacuum HiCube80 Eco Turbo Pumping Station is the trully portable and bench top pumping unit for many of the High Vacuum Applications. CF-F Inlet Flange makes this system trully Ultra High Vacuum (UHV).

The Hicube 80 Station has a modern design with the latest turbo pump and electronics technology.

What’s so special about the HiCube vacuum solution: The combination of a turbopump from the HiPace series and a backing pump designed for the user’s specific application needs. We offer you the HiCube in Pro and Classic versions; available with dry compressing or oil-sealed backing pump and an ultimate pressure of up to 5 · 10-10 hPa.

The HiCube Eco turbo pumping station is distinguished by its modular construction. Thanks to the many possibilities of combining different turbopumps and backing pumps, the HiCube Eco can be configured to meet the requirements of all applications in high and ultra-high vacuums. In addition, all HiCube Eco pumping stations feature connectivity for digital pressure sensors.

 

Hicube 80 Eco Gauge Package Features:


  • Compact series of pumping stations for all high vacuum applications
  • Included MPT200AR Vacuum Gauge with DN 40 CF-F / PTR40150 with Measurement Range From 5 x 10-9 to 1000 hPa
  • Ultimate Pressure: < 1 x 10-7 hPa
  • Pumping Speed for N2: 67 l/s
  • Air-cooled and ready for operation with HiPace 80 Turbo Pump and MVP 015 Dry Diaphragm Backing Pump
  • Pfeiffer HiCube 80 Eco comes with DN 63 CF-F Conflat inlet flange
  • DCU 002 Control Unit
  • Pfieffer HiCube 80 Eco voltage requirement 90-132 V AC, 50/60 Hz; 185-265 V AC, 50/60 Hz
  • Pumping Station Components: HiPace 80, MVP 015-2, TPS 110, DCU 002

 

Typical High Vacuum Hicube80 Eco Applications:


  • Analytical
  • Leak Detection
  • Vacuum process technology
  • Research, Development and Scientific
  • Particle accelerators
  • Electron-beam welding
  • Solar Energy

 

Pfeiffer HiCube 80 Dimensions:


Pfeiffer HiCube 80 Dimensions, PMS03555

 

Pfeiffer MPT 200 Dimensions:


Pfeiffer MPT 200, PT R40 353, PTR40353 Dimensions


Click Here for Pfeiffer HiCube 80 Turbo Pump Station Manual

Click Here for Pfeiffer HiPace 80 Turbo Pump Manual

Click Here for Pfeiffer MVP 015-2 Diaphragm Pump Manual

Click Here for Pfeiffer MPT 200 Gauge Manual


A&J Vacuum repair / rebuild and service all Pfeiffer HiCube Turbo Pumping Stations PM 183 255 T, along with all other  Pfeiffer  Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Pfeiffer Hicube 80 ECO Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267, PFEIFFER HICUBE80 ECO Gauge Package

 

Pfeiffer HiCube 80 Technical Data:


Backing pump MVP 015-2
Cooling method, standard Air
Flange (in) DN 63 ISO-K
Flange (out) Silencer, G 1/8"
Mains connection: Voltage 100 – 240 V
Mains requirement 110 – 240 V AC, 50/60 Hz
Mains requirement: frequency (range) 50/60 Hz
Mains requirement: power consumption 170 W
Power consumption max. 170 W
Pumping speed backing pump at 50 Hz 1 m³/h | 0.59 cfm | 16.67 l/min
Pumping speed for N2 67 l/s
Sound pressure level ≤50 dB(A)
Turbopump HiPace 80
Type Turbo pumping station
Ultimate pressure < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar
Ultimate pressure without gas ballast < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar
Weight 12.1 kg | 26.68 lb

 

Pfeiffer MPT 200 Technical Data:


Accuracy: 1 · 10-8 – 2 · 10-3 hPa ± 25 %
Accuracy: 100 – 1000 hPa ± 50 %
Accuracy: 10 – 100 hPa ± 30 %
Accuracy: 2 · 10-3 – 10 hPa ± 10 %
Ambient temperature 5-60 °C | 41-140 °F | 278-333 K
Anode Molybdenum
Bakeout temperature at the flange 180 °C | 356 °F | 453 K
Cold cathode sensor control Cold Cathode sensor can be switched on and off via interface
Feature Cold Cathode sensor can be switched on and off via interface
I/O interfaces RS-485, DeviceNet
Materials in contact with media Tungsten, stainless steel, nickel, molybdenum, glass
Measurement range 5 · 10-9 – 1 · 103 hPa
Measuring cycle 10 ms
Method of measurement Pirani/Cold Cathode
Nominal diameter DN 25 ISO-KF
Protection category IP54
Repeatability: 1 · 10-2 – 10 hPa ± 2 %
Repeatability: 1 · 10-8 – 1 · 10-2hPa ± 7 %
Seal Metal
Sensor cable length min. 100 m
Supply: power consumption 4.5 W
Supply: Power consumption max. 4.5 W
Temperature: Storage -40-65 °C | -40-149 °F | 233-338 K
Weight 580 g

Click Here for Pfeiffer HiCube 80 Turbo Pump Station Manual

Click Here for Pfeiffer HiPace 80 Turbo Pump Manual

Click Here for Pfeiffer MVP 015-2 Diaphragm Pump Manual

Click Here for Pfeiffer MPT 200 Gauge Manual


A&J Vacuum repair / rebuild and service all Pfeiffer HiCube Turbo Pumping Stations PM 183 255 T, along with all other  Pfeiffer  Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Pfeiffer HiCube 80 Eco Turbo Pumping Station Overview
Name
Price
Item#:
PN02097
Mfr Part#:
GA-0450V
$25.00
$850.00
Item#:
PN17961
Mfr Part#:
PN17961
$17.75
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer HiCube 80 Eco Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267
Item#: PN20188 Mfr Part#: PM 183 255-T / PM183255-T / 2000017267 Manufacturer: Pfeiffer Vacuum

Pfeiffer Hicube 80 Eco Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 PKT05100 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267, PFEIFFER HICUBE80 ECO Gauge Package

 

Pfeiffer HiCube 80 Eco Overview


The Pfeiffer Vacuum HiCube80 Eco Turbo Pumping Station is the trully portable and bench top pumping unit for many of the High Vacuum Applications. CF-F Inlet Flange makes this system trully Ultra High Vacuum (UHV).

The Hicube 80 Station has a modern design with the latest turbo pump and electronics technology.

What’s so special about the HiCube vacuum solution: The combination of a turbopump from the HiPace series and a backing pump designed for the user’s specific application needs. We offer you the HiCube in Pro and Classic versions; available with dry compressing or oil-sealed backing pump and an ultimate pressure of up to 5 · 10-10 hPa.

The HiCube Eco turbo pumping station is distinguished by its modular construction. Thanks to the many possibilities of combining different turbopumps and backing pumps, the HiCube Eco can be configured to meet the requirements of all applications in high and ultra-high vacuums. In addition, all HiCube Eco pumping stations feature connectivity for digital pressure sensors.

 

Hicube 80 Eco Gauge Package Features:


  • Compact series of pumping stations for all high vacuum applications
  • Included MPT200AR Vacuum Gauge with DN 40 CF-F / PTR40150 with Measurement Range From 5 x 10-9 to 1000 hPa
  • Ultimate Pressure: < 1 x 10-7 hPa
  • Pumping Speed for N2: 67 l/s
  • Air-cooled and ready for operation with HiPace 80 Turbo Pump and MVP 015 Dry Diaphragm Backing Pump
  • Pfeiffer HiCube 80 Eco comes with DN 63 CF-F Conflat inlet flange
  • DCU 002 Control Unit
  • Pfieffer HiCube 80 Eco voltage requirement 90-132 V AC, 50/60 Hz; 185-265 V AC, 50/60 Hz
  • Pumping Station Components: HiPace 80, MVP 015-2, TPS 110, DCU 002

 

Typical High Vacuum Hicube80 Eco Applications:


  • Analytical
  • Leak Detection
  • Vacuum process technology
  • Research, Development and Scientific
  • Particle accelerators
  • Electron-beam welding
  • Solar Energy

 

Pfeiffer HiCube 80 Dimensions:


Pfeiffer HiCube 80 Dimensions, PMS03555

 

Pfeiffer MPT 200 Dimensions:


Pfeiffer MPT 200, PT R40 353, PTR40353 Dimensions


Click Here for Pfeiffer HiCube 80 Turbo Pump Station Manual

Click Here for Pfeiffer HiPace 80 Turbo Pump Manual

Click Here for Pfeiffer MVP 015-2 Diaphragm Pump Manual

Click Here for Pfeiffer MPT 200 Gauge Manual


A&J Vacuum repair / rebuild and service all Pfeiffer HiCube Turbo Pumping Stations PM 183 255 T, along with all other  Pfeiffer  Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Pfeiffer Hicube 80 ECO Turbo Pumping Station, Includes HiPace 80 Turbo Pump (DN 63 CF-F), MPT200AR Gauge (DN 40 CF-F), MVP 015 Diaphragm Vacuum Pump and DCU 002 Control Unit, PM 183 255-T / PM183255-T / 2000017267, PFEIFFER HICUBE80 ECO Gauge Package

 

Pfeiffer HiCube 80 Technical Data:


Backing pump MVP 015-2
Cooling method, standard Air
Flange (in) DN 63 ISO-K
Flange (out) Silencer, G 1/8"
Mains connection: Voltage 100 – 240 V
Mains requirement 110 – 240 V AC, 50/60 Hz
Mains requirement: frequency (range) 50/60 Hz
Mains requirement: power consumption 170 W
Power consumption max. 170 W
Pumping speed backing pump at 50 Hz 1 m³/h | 0.59 cfm | 16.67 l/min
Pumping speed for N2 67 l/s
Sound pressure level ≤50 dB(A)
Turbopump HiPace 80
Type Turbo pumping station
Ultimate pressure < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar
Ultimate pressure without gas ballast < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar
Weight 12.1 kg | 26.68 lb

 

Pfeiffer MPT 200 Technical Data:


Accuracy: 1 · 10-8 – 2 · 10-3 hPa ± 25 %
Accuracy: 100 – 1000 hPa ± 50 %
Accuracy: 10 – 100 hPa ± 30 %
Accuracy: 2 · 10-3 – 10 hPa ± 10 %
Ambient temperature 5-60 °C | 41-140 °F | 278-333 K
Anode Molybdenum
Bakeout temperature at the flange 180 °C | 356 °F | 453 K
Cold cathode sensor control Cold Cathode sensor can be switched on and off via interface
Feature Cold Cathode sensor can be switched on and off via interface
I/O interfaces RS-485, DeviceNet
Materials in contact with media Tungsten, stainless steel, nickel, molybdenum, glass
Measurement range 5 · 10-9 – 1 · 103 hPa
Measuring cycle 10 ms
Method of measurement Pirani/Cold Cathode
Nominal diameter DN 25 ISO-KF
Protection category IP54
Repeatability: 1 · 10-2 – 10 hPa ± 2 %
Repeatability: 1 · 10-8 – 1 · 10-2hPa ± 7 %
Seal Metal
Sensor cable length min. 100 m
Supply: power consumption 4.5 W
Supply: Power consumption max. 4.5 W
Temperature: Storage -40-65 °C | -40-149 °F | 233-338 K
Weight 580 g

Click Here for Pfeiffer HiCube 80 Turbo Pump Station Manual

Click Here for Pfeiffer HiPace 80 Turbo Pump Manual

Click Here for Pfeiffer MVP 015-2 Diaphragm Pump Manual

Click Here for Pfeiffer MPT 200 Gauge Manual


A&J Vacuum repair / rebuild and service all Pfeiffer HiCube Turbo Pumping Stations PM 183 255 T, along with all other  Pfeiffer  Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Pfeiffer HiCube 80 Eco Turbo Pumping Station Overview
Name
Price
Item#:
PN02097
Mfr Part#:
GA-0450V
$25.00
$850.00
Item#:
PN17961
Mfr Part#:
PN17961
$17.75
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.