Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System
Item#: PN20824 Mfr Part#: Manufacturer: Pfeiffer Vacuum
Condition: Discontinued
Discontinued Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System

Features:
  • Complete Measurement package
  • TPG 362 Digital Controller
  • TPR 280 CF 16, IKR 251 CF 40 Gauge Head
  • 2 - 3M Connecting Cable and 115V Mains Cables

This product has been discontinued and is no longer available for sale
Item#: PN20824 Mfr Part#:
Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System
Item#: PN20824 Mfr Part#: Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System

 

Included:



  • DualGaugeDisplay and control unit for two guages 100-250VAC, 50/60Hz, TPG 362, PT G28 290
  • Active Pirani transmitter TPR 280, CF 16, PT R26 951 A
  • ActiveCold Cathode Transmiter, IKR 251, CF 40, PT R25 502
  • 2 Gauige cables, length: 3 m

 

Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40)  and 3m Cables Pressure Measurement System

Universal power supply for worldwide use.

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System

 

Technical Data TPG 362:


Ambient Temperature 5-50 °C | 41-122 °F | 278-323 K
Automatic Changeover: Pirani/Cold Cathode Configurable
Connection for Gauge 2
Display Rate ≥ 10 Hz
Error Signal: Working Contact, Potential-Free 1 Pcs.
Filter Time Constant, Rapid/Normal/Slow 0.02 s/0.15 s/0.75 s  
I/O Interfaces USB, RS-485, Ethernet
Mains Requirement: Frequency (Range) 50/60 Hz
Mains Requirement: Power Consumption 65 VA
Mains Requirement: Voltage (Range) 100–240 V
Measurement Range 5 * 10^[-11] – 5.5 * 10^4 hPa
Measurement Rate ≥ 100 Hz
Measuring Channel 2 Pcs.
Power Consumption Max.. 65 VA
Protection Category IP20
Safety CE, UL
Set Point: Changeover Contact, Potential-Free 4 Pcs.
Set Point: Current AC 1 A
Set Point: Current DC 0.5 A
Set Point: Voltage AC 30 V AC
Set Point: Voltage DC 60 V DC
Set Point Number 4 Pcs.
Signal Output: Measuring Value, Analog 0 – 10 V
Temperature: Storage -20-60 °C | -4-140 °F | 253-333 K
Weight 1.1 kg | 2.43 lb

 

Technical Data TPR 280:


Accuracy: 1 * 10^(-3) to 100 hPa ± 15 %
Ambient Temperature 5-60 °C | 41-140 °F | 278-333 K
Bakeout Temperature at Flange 80 °C | 176 °F | 353 K
Feature Stainless Steel, Metal Sealed
Feedthrough Glass
Filament Tungsten
Flange Material Stainless Steel
Measurement Range 5 * 10^(-4) to 10^(3hPa
Nominal Diameter DN 16 CF-R
Output Signal: Measurement Range 2.2–8.5 V  
Output signal: Minimum Load 10 k
Maximum Pressure 10,000 hPa | 7,500 Torr | 10,000 mbar
Protection category IP40
Repeatability: 1 * 10^(-3) to 100 hPa ± 2 %
Resolution 1 % of reading
Response Time 80 ms
Seal Metal
Sensor Cable Length Min. 200 m
Supply: Power Consumption Max. 1 W
Supply: Voltage V DC 14 – 30 V DC
Storage Temperature -20-65 °C | -4-149 °F | 253-338 K
Volume 1.5 cm³
Weight 100 g

 

Technical Data IKR 251:


Inlet Flange: DN 40 CF-F
Maximum Measurement Range: 0.01 hPa
Minimum Measurement Range: 2 x 10-9 hPa
Output Signal: 1.8 to 8.5 V
Maximum Pressure: 1000 kPa
Supply Voltage: 15 to 30 V
Weight: 700 g / 1.5 lbs


| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System
Item#: PN20824 Mfr Part#: Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System

 

Included:



  • DualGaugeDisplay and control unit for two guages 100-250VAC, 50/60Hz, TPG 362, PT G28 290
  • Active Pirani transmitter TPR 280, CF 16, PT R26 951 A
  • ActiveCold Cathode Transmiter, IKR 251, CF 40, PT R25 502
  • 2 Gauige cables, length: 3 m

 

Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40)  and 3m Cables Pressure Measurement System

Universal power supply for worldwide use.

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

Pfeiffer Vacuum TPG 362 Single Gauge with 1 TPR 280 (CF-16), IKR 251 (CF40) and 3m Cables Pressure Measurement System

 

Technical Data TPG 362:


Ambient Temperature 5-50 °C | 41-122 °F | 278-323 K
Automatic Changeover: Pirani/Cold Cathode Configurable
Connection for Gauge 2
Display Rate ≥ 10 Hz
Error Signal: Working Contact, Potential-Free 1 Pcs.
Filter Time Constant, Rapid/Normal/Slow 0.02 s/0.15 s/0.75 s  
I/O Interfaces USB, RS-485, Ethernet
Mains Requirement: Frequency (Range) 50/60 Hz
Mains Requirement: Power Consumption 65 VA
Mains Requirement: Voltage (Range) 100–240 V
Measurement Range 5 * 10^[-11] – 5.5 * 10^4 hPa
Measurement Rate ≥ 100 Hz
Measuring Channel 2 Pcs.
Power Consumption Max.. 65 VA
Protection Category IP20
Safety CE, UL
Set Point: Changeover Contact, Potential-Free 4 Pcs.
Set Point: Current AC 1 A
Set Point: Current DC 0.5 A
Set Point: Voltage AC 30 V AC
Set Point: Voltage DC 60 V DC
Set Point Number 4 Pcs.
Signal Output: Measuring Value, Analog 0 – 10 V
Temperature: Storage -20-60 °C | -4-140 °F | 253-333 K
Weight 1.1 kg | 2.43 lb

 

Technical Data TPR 280:


Accuracy: 1 * 10^(-3) to 100 hPa ± 15 %
Ambient Temperature 5-60 °C | 41-140 °F | 278-333 K
Bakeout Temperature at Flange 80 °C | 176 °F | 353 K
Feature Stainless Steel, Metal Sealed
Feedthrough Glass
Filament Tungsten
Flange Material Stainless Steel
Measurement Range 5 * 10^(-4) to 10^(3hPa
Nominal Diameter DN 16 CF-R
Output Signal: Measurement Range 2.2–8.5 V  
Output signal: Minimum Load 10 k
Maximum Pressure 10,000 hPa | 7,500 Torr | 10,000 mbar
Protection category IP40
Repeatability: 1 * 10^(-3) to 100 hPa ± 2 %
Resolution 1 % of reading
Response Time 80 ms
Seal Metal
Sensor Cable Length Min. 200 m
Supply: Power Consumption Max. 1 W
Supply: Voltage V DC 14 – 30 V DC
Storage Temperature -20-65 °C | -4-149 °F | 253-338 K
Volume 1.5 cm³
Weight 100 g

 

Technical Data IKR 251:


Inlet Flange: DN 40 CF-F
Maximum Measurement Range: 0.01 hPa
Minimum Measurement Range: 2 x 10-9 hPa
Output Signal: 1.8 to 8.5 V
Maximum Pressure: 1000 kPa
Supply Voltage: 15 to 30 V
Weight: 700 g / 1.5 lbs


We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.