Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T
Item#: PN20866 Mfr Part#: BN846250-T Manufacturer: Pfeiffer Vacuum
Condition: New
New Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T

Features:

PRICE: $565.00
WEB SAVINGS: $70.00
YOU PAY: $495.00
Item#: PN20866 Mfr Part#: BN846250-T
Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T
Item#: PN20866 Mfr Part#: BN846250-T Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T

Overview:

New Pfeiffer Vacuum IKR Spare Part Ignition Aid to be used with Cold Cathode Transmitter IKR 250 / 251.

  • Measurement range from 2 · 10-9 to 0.01 mbar
  • Cold cathode (inverted magnetron)
  • Rugged and dependable
  • Insensitive to air ingress
  • Corrosion-resistant
  • Maximum pressure refers to inert gases and temperatures of less than 55 °C


THERE ARE NO RETURNS ON THIS PRODUCT.

Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T

Technical Data:

Accuracy: 10-8 - 10-3 mbar ± 30 %
Bakeout temperature 150 °C
Feature Interior FPM sealed
Feedthrough Al2O3
Filament Molybdenum
Flange Stainless steel
Flange (in) DN 40 ISO-KF
Measurement range max. 0.01 mbar
Measurement range min. 2 · 10-9 mbar
Output signal: Minimum load 10 k?
Output signal: Pressure range 1.8 - 8.5 V
Output signal: Sensor error below 0.5 V
Pressure max. 10 bar
Repeatability: 10-8 - 10-3 mbar ± 5 %
Seal FPM
Sensor cable length 500 m
Supply: Power consumption max. 2 W
Supply: Voltage 15-30 V
Temperature: Operating 5-55 °C
Temperature: Storage -40- °C
Volume 20 cm3
Weight 700 g
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T
Item#: PN20866 Mfr Part#: BN846250-T Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T

Overview:

New Pfeiffer Vacuum IKR Spare Part Ignition Aid to be used with Cold Cathode Transmitter IKR 250 / 251.

  • Measurement range from 2 · 10-9 to 0.01 mbar
  • Cold cathode (inverted magnetron)
  • Rugged and dependable
  • Insensitive to air ingress
  • Corrosion-resistant
  • Maximum pressure refers to inert gases and temperatures of less than 55 °C


THERE ARE NO RETURNS ON THIS PRODUCT.

Pfeiffer Vacuum IKR 250, IKR251 Set of Filters (10 pcs.), BN846250-T

Technical Data:

Accuracy: 10-8 - 10-3 mbar ± 30 %
Bakeout temperature 150 °C
Feature Interior FPM sealed
Feedthrough Al2O3
Filament Molybdenum
Flange Stainless steel
Flange (in) DN 40 ISO-KF
Measurement range max. 0.01 mbar
Measurement range min. 2 · 10-9 mbar
Output signal: Minimum load 10 k?
Output signal: Pressure range 1.8 - 8.5 V
Output signal: Sensor error below 0.5 V
Pressure max. 10 bar
Repeatability: 10-8 - 10-3 mbar ± 5 %
Seal FPM
Sensor cable length 500 m
Supply: Power consumption max. 2 W
Supply: Voltage 15-30 V
Temperature: Operating 5-55 °C
Temperature: Storage -40- °C
Volume 20 cm3
Weight 700 g
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.