BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241
Item#: PN20949 Mfr Part#: 4760241 Manufacturer: Brandtech
Condition: New
New BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241

Features:
  • PN 4760241
  • 4 PP bottle adapters included
  • Easy Calibration technology
  • Class A precision

PRICE: $1,484.00
WEB SAVINGS: $261.00
YOU PAY: $1,223.00
Item#: PN20949 Mfr Part#: 4760241
BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241
Item#: PN20949 Mfr Part#: 4760241 Manufacturer: Brandtech

BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241


 

Overview

Titrette® Bottletop Burette

The BRAND Titrette® is the only bottletop burette that meets Class A accuracy specifications for glass burettes. If needed, it can offer the precision of 3 decimal places below 20mL. It can be quickly and easily disassembled in a matter of minutes - for cleaning, to replace the piston or cylinder, or to replace the batteries. Available in volumes from 10mL to 50mL, and with an optional RS232 communications interface.

Titrette® offers the following features:

  • The 45mm standard thread, plus included adapters, fit most common lab bottles

  • Titrating tube can be adjusted horizontally and vertically

  • Integrated SafetyPrime™valve reduces waste of valuable reagents

  • Clip-on amber-colored window protects light-sensitive reagents

  • Valves replaceable for simple, economical service

  • Large handwheels provide smooth, precise control

  • Compact design and light weight ensure good stability

 

BrandTech Titrette® Bottletop Burette Operating Instructions Click Here

 

This item is non-returnable/non-refundable

BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241

 

The Titrette® bottletop burette is supplied with: 45mm thread, telescoping filling tube (170-330mm), recirculation tube, 2 batteries (AAA/UM4/LR03), 3 bottletop adapters, 2 amber colored light shield inspection windows, performance certificate, operating manual, and one-year warranty. Additionally included with RS232 interface: 2m interface cable (9-pin, sub-D plug connector), CD (driver software and open RS232 communication protocol).

  Volume
   mL
Partial Volume
mL
A* ≤ ±
CV* ≤
Standard
Cat. No.
Interface
Cat. No.
%
µL
%
µL
  10
10
0.10
10
0.05
5
4760141
4760241
 
5
0.20
10
0.10
5
 
 
 
1
1.00
10
0.50
5
 
 
  25
25
0.07
18
0.025
6
4760151
4760251
 
12.5
0.14
18
0.05
6
 
 
 
2.5
0.70
18
0.25
6
 
 
  50
50
0.06
30
0.02
10
4760161
4760261
 
25
0.12
30
0.04
10
 
 
 
5
0.60
30
0.20
10
 
 

A*=Accuracy, CV*=Coefficient of Variation

*The value of accuracy and coefficient of variation are final test values referring ot the delivered nominal volume, instrument and distilled water at equilibrium with ambient temperature (20°C/68°F) and with smooth operation.

 

 

Overview

Titrette® Bottletop Burette

Titrette® Bottletop Burette is supplied with following items:

  • 45mm thread

  • Performace certificate

  • Telescoping filling tube, 170-330mm

  • Recirculation tube

  • 2 batteries, AAA/UM4/LR03

  • 4 PP bottle adapters, 45/33mm, 45/S40mm, 33mm/STJ29/32 and 45/38mm

  • 2 colored light shield inspection windows

  • Operating manual

  • One-year warranty

 

Limitations of Use:

This instrument is designed for dispensing liquids, observing the following physical limits:

  • Temperature of instrument and reagent must be between +15°C and +40°C (59°F and 104°F)

  • Altitude: maximum 3000m above sea-level

  • Relative air humididty: 20% to 90%

  • Vapor pressure up to 500 mbar

  • Viscosity up to 500 mm²/s

 

Operating Exclusions:

Never use this instrument with:

  • Liquids attacking Al2O3, ETFE, FEP, PFA, PTFE or platinum-iridium

  • Liquids attacking borosilicate glass (e.g., hydrofluoric acid)

  • Suspensions (e.g., of charcoal) as solid particles may clog or damage the instrument

  • Liquids which are explosive or flammable (e.g., carbon disulfide)

  • Concentrated acids and bases as well as non-polar solvents which effect swelling of plastics (e.g., Toluene, Benzene)

  • The instrument should not be autoclaved!

  • The instrument should not be used in an aggressive atmosphere (e.g., HCl fumes).

 

BrandTech Titrette® Bottletop Burette Operating Instructions Click Here

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241
Item#: PN20949 Mfr Part#: 4760241 Manufacturer: Brandtech

BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241


 

Overview

Titrette® Bottletop Burette

The BRAND Titrette® is the only bottletop burette that meets Class A accuracy specifications for glass burettes. If needed, it can offer the precision of 3 decimal places below 20mL. It can be quickly and easily disassembled in a matter of minutes - for cleaning, to replace the piston or cylinder, or to replace the batteries. Available in volumes from 10mL to 50mL, and with an optional RS232 communications interface.

Titrette® offers the following features:

  • The 45mm standard thread, plus included adapters, fit most common lab bottles

  • Titrating tube can be adjusted horizontally and vertically

  • Integrated SafetyPrime™valve reduces waste of valuable reagents

  • Clip-on amber-colored window protects light-sensitive reagents

  • Valves replaceable for simple, economical service

  • Large handwheels provide smooth, precise control

  • Compact design and light weight ensure good stability

 

BrandTech Titrette® Bottletop Burette Operating Instructions Click Here

 

BrandTech Titrette® Bottletop Burette, 10 mL, with Optional RS232 Communications Interface, 4760241

 

The Titrette® bottletop burette is supplied with: 45mm thread, telescoping filling tube (170-330mm), recirculation tube, 2 batteries (AAA/UM4/LR03), 3 bottletop adapters, 2 amber colored light shield inspection windows, performance certificate, operating manual, and one-year warranty. Additionally included with RS232 interface: 2m interface cable (9-pin, sub-D plug connector), CD (driver software and open RS232 communication protocol).

  Volume
   mL
Partial Volume
mL
A* ≤ ±
CV* ≤
Standard
Cat. No.
Interface
Cat. No.
%
µL
%
µL
  10
10
0.10
10
0.05
5
4760141
4760241
 
5
0.20
10
0.10
5
 
 
 
1
1.00
10
0.50
5
 
 
  25
25
0.07
18
0.025
6
4760151
4760251
 
12.5
0.14
18
0.05
6
 
 
 
2.5
0.70
18
0.25
6
 
 
  50
50
0.06
30
0.02
10
4760161
4760261
 
25
0.12
30
0.04
10
 
 
 
5
0.60
30
0.20
10
 
 

A*=Accuracy, CV*=Coefficient of Variation

*The value of accuracy and coefficient of variation are final test values referring ot the delivered nominal volume, instrument and distilled water at equilibrium with ambient temperature (20°C/68°F) and with smooth operation.

 

 

Overview

Titrette® Bottletop Burette

Titrette® Bottletop Burette is supplied with following items:

  • 45mm thread

  • Performace certificate

  • Telescoping filling tube, 170-330mm

  • Recirculation tube

  • 2 batteries, AAA/UM4/LR03

  • 4 PP bottle adapters, 45/33mm, 45/S40mm, 33mm/STJ29/32 and 45/38mm

  • 2 colored light shield inspection windows

  • Operating manual

  • One-year warranty

 

Limitations of Use:

This instrument is designed for dispensing liquids, observing the following physical limits:

  • Temperature of instrument and reagent must be between +15°C and +40°C (59°F and 104°F)

  • Altitude: maximum 3000m above sea-level

  • Relative air humididty: 20% to 90%

  • Vapor pressure up to 500 mbar

  • Viscosity up to 500 mm²/s

 

Operating Exclusions:

Never use this instrument with:

  • Liquids attacking Al2O3, ETFE, FEP, PFA, PTFE or platinum-iridium

  • Liquids attacking borosilicate glass (e.g., hydrofluoric acid)

  • Suspensions (e.g., of charcoal) as solid particles may clog or damage the instrument

  • Liquids which are explosive or flammable (e.g., carbon disulfide)

  • Concentrated acids and bases as well as non-polar solvents which effect swelling of plastics (e.g., Toluene, Benzene)

  • The instrument should not be autoclaved!

  • The instrument should not be used in an aggressive atmosphere (e.g., HCl fumes).

 

BrandTech Titrette® Bottletop Burette Operating Instructions Click Here

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.