Overview
HandyStep S Repeating Pipette
The BRAND HandyStep S repeating pipette provides unprecedented versatility in a purely mechanical repeating pipette. In conjunction with BRAND PD-Tip Precision Dispenser Tips, the HandyStep S offers nearly sixty different volume settings with accuracy, precision and dependability.
HandyStep S Repeating Pipette offers the following features:
The slim design of the HandyStep S is lightweight, well-balanced, and provides a convenient control layout for smooth dispensing and one-handed volume selection.
Robust construction, inspired design and innovative plymers deliver a dependable instrument.
A purely mechanical design with no batteries to charge or replac e meand the HandyStep S is ready when you are. A convenient integrated volume table provides a quick reference for dispensed volumes.
Ten sizes of PD-Tip Precision Dispenser Tips allow the HandyStep S to dispense 59 different volumes. Open design allows use of third party tips - no more being locked into a sole source!
A tip ejection system allows the user to remove tips without handling.
The HandyStep® S is supplied with a performance certificate, shelf/rack mount, one each: 0.1mL, 1mL and 10mL PD-Tip™ syringe tips, operating manual and two-year warranty.
HandyStep® S Volume Table with PD-Tip™ Syringe Tips
Settings
|
1
|
1.5
|
2
|
2.5
|
3
|
3.5
|
4
|
4.5
|
5
|
---|---|---|---|---|---|---|---|---|---|
Steps
|
49
|
32
|
24
|
19
|
15
|
13
|
11
|
10
|
9
|
PD-Tip™
size |
Volume, µL
|
||||||||
0.1mL
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
0.5mL
|
10
|
15
|
20
|
25
|
30
|
35
|
40
|
45
|
50
|
1.0mL
|
20
|
30
|
40
|
50
|
60
|
70
|
80
|
90
|
100
|
1.25mL
|
25
|
37.5
|
50
|
62.5
|
75
|
87.5
|
100
|
112.5
|
125
|
2.5mL
|
50
|
75
|
100
|
125
|
150
|
175
|
200
|
225
|
250
|
5.0mL
|
100
|
150
|
200
|
250
|
300
|
350
|
400
|
450
|
500
|
10.0mL
|
200
|
300
|
400
|
500
|
600
|
700
|
800
|
900
|
1000
|
12.5mL
|
250
|
375
|
500
|
625
|
750
|
875
|
1000
|
1125
|
1250
|
25.0mL
|
500
|
750
|
1000
|
1250
|
1500
|
1750
|
2000
|
2250
|
2500
|
50.0mL
|
1000
|
1500
|
2000
|
2500
|
3000
|
3500
|
4000
|
4500
|
5000
|
HandyStep® S Accuracy and Precision with PD-Tip™ Syringe Tips
PD-Tip™
size |
Volume Range
|
Stroke setting ≡ % of nominal
volume (A* ≤ ± %) |
Stroke setting ≡ % of nominal
volume (CV* ≤ %) |
||||
---|---|---|---|---|---|---|---|
1 ≡ 2%
|
3 ≡ 6%
|
5 ≡ 10%
|
1 ≡ 2%
|
3 ≡ 6%
|
5 ≡ 10%
|
||
0.1mL
|
2µL-10µL
|
4.0
|
2.4
|
1.6
|
6.0
|
3.0
|
2.0
|
0.5mL
|
10µL-50µL
|
2.5
|
1.5
|
1.0
|
2.5
|
1.5
|
1.0
|
1.0mL
|
20µL-100µL
|
2.5
|
1.5
|
1.0
|
2.0
|
1.2
|
0.8
|
1.25mL
|
25µL-125µL
|
2.5
|
1.4
|
0.9
|
2.0
|
1.1
|
0.7
|
2.5mL
|
50µL-250µL
|
1.8
|
1.1
|
0.7
|
1.5
|
0.9
|
0.6
|
5.0mL
|
100µL-500µL
|
1.8
|
1.1
|
0.7
|
1.5
|
0.9
|
0.7
|
10.0mL
|
200µL-1000µL
|
1.8
|
1.1
|
0.7
|
2.0
|
1.2
|
0.8
|
12.5mL
|
250µL-1250µL
|
1.8
|
1.1
|
0.8
|
3.2
|
2.0
|
1.4
|
25.0mL
|
500µL-2500µL
|
1.5
|
0.9
|
0.6
|
3.04
|
1.5
|
1.0
|
50.0mL
|
1000µL-5000µL
|
1.5
|
0.8
|
0.5
|
5.0
|
1.8
|
1.2
|
Limitations of Use:
This instrument is designed for dispensing samples, observing the following physical limits:
Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent
Vapor pressure up to 500 mbar
Kinematic viscosity:
20 mPa/s with 50mL PD-Tip™ syringe tips
260 mPa/s with 5mL PD-Tip™ syringe tips
977 mPa/s with 1mL PD-Tip™ syringe tips
Operating Exclusions:
This instrument is designed for dispensing samples, observing the following physical limits:
Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent
Vapor pressure up to 500 mbar
Kinematic viscosity:
20 mPa/s with 50mL PD-Tip™ syringe tips
260 mPa/s with 5mL PD-Tip™ syringe tips
977 mPa/s with 1mL PD-Tip™ syringe tips
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Overview
HandyStep S Repeating Pipette
The BRAND HandyStep S repeating pipette provides unprecedented versatility in a purely mechanical repeating pipette. In conjunction with BRAND PD-Tip Precision Dispenser Tips, the HandyStep S offers nearly sixty different volume settings with accuracy, precision and dependability.
HandyStep S Repeating Pipette offers the following features:
The slim design of the HandyStep S is lightweight, well-balanced, and provides a convenient control layout for smooth dispensing and one-handed volume selection.
Robust construction, inspired design and innovative plymers deliver a dependable instrument.
A purely mechanical design with no batteries to charge or replac e meand the HandyStep S is ready when you are. A convenient integrated volume table provides a quick reference for dispensed volumes.
Ten sizes of PD-Tip Precision Dispenser Tips allow the HandyStep S to dispense 59 different volumes. Open design allows use of third party tips - no more being locked into a sole source!
A tip ejection system allows the user to remove tips without handling.
The HandyStep® S is supplied with a performance certificate, shelf/rack mount, one each: 0.1mL, 1mL and 10mL PD-Tip™ syringe tips, operating manual and two-year warranty.
HandyStep® S Volume Table with PD-Tip™ Syringe Tips
Settings
|
1
|
1.5
|
2
|
2.5
|
3
|
3.5
|
4
|
4.5
|
5
|
---|---|---|---|---|---|---|---|---|---|
Steps
|
49
|
32
|
24
|
19
|
15
|
13
|
11
|
10
|
9
|
PD-Tip™
size |
Volume, µL
|
||||||||
0.1mL
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
0.5mL
|
10
|
15
|
20
|
25
|
30
|
35
|
40
|
45
|
50
|
1.0mL
|
20
|
30
|
40
|
50
|
60
|
70
|
80
|
90
|
100
|
1.25mL
|
25
|
37.5
|
50
|
62.5
|
75
|
87.5
|
100
|
112.5
|
125
|
2.5mL
|
50
|
75
|
100
|
125
|
150
|
175
|
200
|
225
|
250
|
5.0mL
|
100
|
150
|
200
|
250
|
300
|
350
|
400
|
450
|
500
|
10.0mL
|
200
|
300
|
400
|
500
|
600
|
700
|
800
|
900
|
1000
|
12.5mL
|
250
|
375
|
500
|
625
|
750
|
875
|
1000
|
1125
|
1250
|
25.0mL
|
500
|
750
|
1000
|
1250
|
1500
|
1750
|
2000
|
2250
|
2500
|
50.0mL
|
1000
|
1500
|
2000
|
2500
|
3000
|
3500
|
4000
|
4500
|
5000
|
HandyStep® S Accuracy and Precision with PD-Tip™ Syringe Tips
PD-Tip™
size |
Volume Range
|
Stroke setting ≡ % of nominal
volume (A* ≤ ± %) |
Stroke setting ≡ % of nominal
volume (CV* ≤ %) |
||||
---|---|---|---|---|---|---|---|
1 ≡ 2%
|
3 ≡ 6%
|
5 ≡ 10%
|
1 ≡ 2%
|
3 ≡ 6%
|
5 ≡ 10%
|
||
0.1mL
|
2µL-10µL
|
4.0
|
2.4
|
1.6
|
6.0
|
3.0
|
2.0
|
0.5mL
|
10µL-50µL
|
2.5
|
1.5
|
1.0
|
2.5
|
1.5
|
1.0
|
1.0mL
|
20µL-100µL
|
2.5
|
1.5
|
1.0
|
2.0
|
1.2
|
0.8
|
1.25mL
|
25µL-125µL
|
2.5
|
1.4
|
0.9
|
2.0
|
1.1
|
0.7
|
2.5mL
|
50µL-250µL
|
1.8
|
1.1
|
0.7
|
1.5
|
0.9
|
0.6
|
5.0mL
|
100µL-500µL
|
1.8
|
1.1
|
0.7
|
1.5
|
0.9
|
0.7
|
10.0mL
|
200µL-1000µL
|
1.8
|
1.1
|
0.7
|
2.0
|
1.2
|
0.8
|
12.5mL
|
250µL-1250µL
|
1.8
|
1.1
|
0.8
|
3.2
|
2.0
|
1.4
|
25.0mL
|
500µL-2500µL
|
1.5
|
0.9
|
0.6
|
3.04
|
1.5
|
1.0
|
50.0mL
|
1000µL-5000µL
|
1.5
|
0.8
|
0.5
|
5.0
|
1.8
|
1.2
|
Limitations of Use:
This instrument is designed for dispensing samples, observing the following physical limits:
Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent
Vapor pressure up to 500 mbar
Kinematic viscosity:
20 mPa/s with 50mL PD-Tip™ syringe tips
260 mPa/s with 5mL PD-Tip™ syringe tips
977 mPa/s with 1mL PD-Tip™ syringe tips
Operating Exclusions:
This instrument is designed for dispensing samples, observing the following physical limits:
Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent
Vapor pressure up to 500 mbar
Kinematic viscosity:
20 mPa/s with 50mL PD-Tip™ syringe tips
260 mPa/s with 5mL PD-Tip™ syringe tips
977 mPa/s with 1mL PD-Tip™ syringe tips
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.