BrandTech HandyStep S Electronic, Repeating Pipette, 705002
Item#: PN21058 Mfr Part#: 705002 Manufacturer: Brandtech
Condition: New
New BrandTech HandyStep S Electronic, Repeating Pipette, 705002

Features:
  • PN 705002
  • Auto-dispense mode
  • Contact-free tip ejection
  • Compatible with PD-Tip precision dispenser tips

Price upon request
Item#: PN21058 Mfr Part#: 705002
BrandTech HandyStep S Electronic, Repeating Pipette, 705002
Item#: PN21058 Mfr Part#: 705002 Manufacturer: Brandtech

BrandTech HandyStep S Electronic, Repeating Pipette, 705002


 

This product is discontinued. Please contact us for replacement information.

 

Overview

HandyStep S Electronic Repeating Pipette

The HandyStep® electronic is an ergonomic alternative to conventional repeating pipettes. When using our unique Auto-dispense mode, it can reduce repetitive pipetting motion by up to 97%. It is compatible with all standard syringe tips. Because of its broad tip compatibility, the HandyStep® electronic can dispense any volume between 1.0µL and 50mL, including non-standard volumes such as 9.2µL, 25µL, 260µL, or 1250µL.

Product Features (HandyStep® electronic):

  • Three pipetting modes for greater productivity: Pipette, Dispense and Auto-Dispense

  • Easy to read LCD screen features a counter to assist with repetitive dispensing and is easy to read during both right- and left-handed operation

  • Ergonomic design reduces risk of repetitive motion injuries, and improves precision by eliminating variation in pipetting technique

  • Tip recognition mechanism automatically displays tip volume and default dispensing volume when a BRAND PD-tip™ syringe tip is inserted

 

BrandTech HandyStep S Electronic Repeating Pipette Operating Instructions, Click Here

This item is non-returnable/non-refundable

BrandTech HandyStep S Electronic, Repeating Pipette, 705002


The HandyStep® electronic is supplied with a performance certificate, NiMH battery, charging stand with power supply, 5 assorted PD-Tip™ syringe tips, operating manual and one-year warranty.

HandyStep® electronic Accuracy and Precision with PD-Tip™ Syringe Tips

 PD-Tip™
 size
Volume
Range
Volumes
Between
Increment
Nominal volume (A* ≤ ± %)
Nominal volume (CV* ≤ %)
 100%
50%
10%
1%
100%
50%
10%
1%
 0.1mL
1µL-100µL
1µL-100µL
0.1µL
1.0
1.0
1.6
8.0
0.5
1.0
2.0
12
 0.5mL
5µL-500µL
5µL-100µL
100µL-500µL
0.1µL
1µL
0.9
0.9
1.0
5.0
0.3
0.6
1.0
5.0
 1.0mL
10µL-1000µL
10µL-1000µL
1µL
0.6
0.9
1.0
5.0
0.3
0.5
0.8
4.0
 1.25mL
12.5µL-1250µL
12.5µL-100µL
100µL-1000µL
1mL-1.25mL
0.5µL
1µL
10µL
0.6
0.6
0.9
5.0
0.2
0.5
0.7
4.0
 2.5mL
25µL-2500µL
25µL-1000µL
1mL-2.5mL
1µL
10µL
0.5
0.6
0.7
3.5
0.15
0.3
0.6
3.0
 5.0mL
50µL-5000µL
50µL-1000µL
1mL-5mL
1µL
10µL
0.5
0.5
0.7
3.5
0.15
0.4
0.7
3.0
 10.0mL
100µL-10mL
100µL-10mL
10µL
0.4
0.5
0.7
3.5
0.15
0.5
0.8
4.0
 12.5mL
125µL-12.5mL
125µL-1000µL
1mL-10mL
10mL-12.5mL
5µL
10µL
100µL
0.5
0.5
0.8
3.5
0.15
0.6
1.4
6.5
 25.0mL
250µL-25mL
250µL-10mL
10mL-25mL
10µL
100µL
0.5
0.5
0.6
3.0
0.15
0.3
1.0
6.0
 50.0mL
500µL-50mL
500µL-10mL
10mL-50mL
10µL
100µL
0.5
0.5
0.5
3.0
0.15
0.4
1.2
9.0

 

A*=Accuracy, CV*=Coefficient of Variation

*Results were achieved using PD-Tip™ syringe tips from BRAND with distilled water and instrument equilibrated at ambient temperature (20° C), and with smooth operation. Empirical values may differ from values obtained under test conditions due to variations in factors beyond our control, including temperature.

The predetermined ISO 8655-5 tolerances were not exceeded.

 

Limitations of Use:

This instrument is designed for dispensing samples, observing the following physical limits:

  • Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent

  • Vapor pressure up to 500 mbar

  • Kinematic viscosity:

    •  20 mPa/s with 50mL PD-Tip™ syringe tips

    • 260 mPa/s with 5mL PD-Tip™ syringe tips

    • 977 mPa/s with 1mL PD-Tip™ syringe tips

 

Operating Exclusions:

Never use this instrument with:

  • Liquids attacking polypropylene (PD-Tip™ cylinder), polyethylene (PD-Tip™ piston), LCP (PD-Tip™ piston 0.1mL), or PC/PBT and polycarbonate

  • Avoid aggressive fumes (danger of corrosion)

  • Oxidizing liquids - can attack metallic parts and the electronics (HandyStep® electronic)

Note: Instrument and tips are not autoclavable (BIO-CERT® PD-Tip™ syringe tips are available). For disinfection of instrument you may use commercially available disinfecting solutions as long as they do not attack PC/PBT or damage the display on the HandyStep® electronic.

 

BrandTech HandyStep S Electronic Repeating Pipette Operating Instructions, Click Here

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

BrandTech HandyStep S Electronic, Repeating Pipette, 705002
Item#: PN21058 Mfr Part#: 705002 Manufacturer: Brandtech

BrandTech HandyStep S Electronic, Repeating Pipette, 705002


 

This product is discontinued. Please contact us for replacement information.

 

Overview

HandyStep S Electronic Repeating Pipette

The HandyStep® electronic is an ergonomic alternative to conventional repeating pipettes. When using our unique Auto-dispense mode, it can reduce repetitive pipetting motion by up to 97%. It is compatible with all standard syringe tips. Because of its broad tip compatibility, the HandyStep® electronic can dispense any volume between 1.0µL and 50mL, including non-standard volumes such as 9.2µL, 25µL, 260µL, or 1250µL.

Product Features (HandyStep® electronic):

  • Three pipetting modes for greater productivity: Pipette, Dispense and Auto-Dispense

  • Easy to read LCD screen features a counter to assist with repetitive dispensing and is easy to read during both right- and left-handed operation

  • Ergonomic design reduces risk of repetitive motion injuries, and improves precision by eliminating variation in pipetting technique

  • Tip recognition mechanism automatically displays tip volume and default dispensing volume when a BRAND PD-tip™ syringe tip is inserted

 

BrandTech HandyStep S Electronic Repeating Pipette Operating Instructions, Click Here

BrandTech HandyStep S Electronic, Repeating Pipette, 705002


The HandyStep® electronic is supplied with a performance certificate, NiMH battery, charging stand with power supply, 5 assorted PD-Tip™ syringe tips, operating manual and one-year warranty.

HandyStep® electronic Accuracy and Precision with PD-Tip™ Syringe Tips

 PD-Tip™
 size
Volume
Range
Volumes
Between
Increment
Nominal volume (A* ≤ ± %)
Nominal volume (CV* ≤ %)
 100%
50%
10%
1%
100%
50%
10%
1%
 0.1mL
1µL-100µL
1µL-100µL
0.1µL
1.0
1.0
1.6
8.0
0.5
1.0
2.0
12
 0.5mL
5µL-500µL
5µL-100µL
100µL-500µL
0.1µL
1µL
0.9
0.9
1.0
5.0
0.3
0.6
1.0
5.0
 1.0mL
10µL-1000µL
10µL-1000µL
1µL
0.6
0.9
1.0
5.0
0.3
0.5
0.8
4.0
 1.25mL
12.5µL-1250µL
12.5µL-100µL
100µL-1000µL
1mL-1.25mL
0.5µL
1µL
10µL
0.6
0.6
0.9
5.0
0.2
0.5
0.7
4.0
 2.5mL
25µL-2500µL
25µL-1000µL
1mL-2.5mL
1µL
10µL
0.5
0.6
0.7
3.5
0.15
0.3
0.6
3.0
 5.0mL
50µL-5000µL
50µL-1000µL
1mL-5mL
1µL
10µL
0.5
0.5
0.7
3.5
0.15
0.4
0.7
3.0
 10.0mL
100µL-10mL
100µL-10mL
10µL
0.4
0.5
0.7
3.5
0.15
0.5
0.8
4.0
 12.5mL
125µL-12.5mL
125µL-1000µL
1mL-10mL
10mL-12.5mL
5µL
10µL
100µL
0.5
0.5
0.8
3.5
0.15
0.6
1.4
6.5
 25.0mL
250µL-25mL
250µL-10mL
10mL-25mL
10µL
100µL
0.5
0.5
0.6
3.0
0.15
0.3
1.0
6.0
 50.0mL
500µL-50mL
500µL-10mL
10mL-50mL
10µL
100µL
0.5
0.5
0.5
3.0
0.15
0.4
1.2
9.0

 

A*=Accuracy, CV*=Coefficient of Variation

*Results were achieved using PD-Tip™ syringe tips from BRAND with distilled water and instrument equilibrated at ambient temperature (20° C), and with smooth operation. Empirical values may differ from values obtained under test conditions due to variations in factors beyond our control, including temperature.

The predetermined ISO 8655-5 tolerances were not exceeded.

 

Limitations of Use:

This instrument is designed for dispensing samples, observing the following physical limits:

  • Use between +15°C and +40°C (59°F and 104°F) of instrument and reagent

  • Vapor pressure up to 500 mbar

  • Kinematic viscosity:

    •  20 mPa/s with 50mL PD-Tip™ syringe tips

    • 260 mPa/s with 5mL PD-Tip™ syringe tips

    • 977 mPa/s with 1mL PD-Tip™ syringe tips

 

Operating Exclusions:

Never use this instrument with:

  • Liquids attacking polypropylene (PD-Tip™ cylinder), polyethylene (PD-Tip™ piston), LCP (PD-Tip™ piston 0.1mL), or PC/PBT and polycarbonate

  • Avoid aggressive fumes (danger of corrosion)

  • Oxidizing liquids - can attack metallic parts and the electronics (HandyStep® electronic)

Note: Instrument and tips are not autoclavable (BIO-CERT® PD-Tip™ syringe tips are available). For disinfection of instrument you may use commercially available disinfecting solutions as long as they do not attack PC/PBT or damage the display on the HandyStep® electronic.

 

BrandTech HandyStep S Electronic Repeating Pipette Operating Instructions, Click Here

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.