BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506
Item#: PN21864 Mfr Part#: 27506 Manufacturer: Brandtech
Condition: New
New BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506

Features:
  • PN 27506
  • Error limits ± mL: 0.007
  • Transparent
  • Pack of 12

PRICE: $81.00
WEB SAVINGS: $8.00
YOU PAY: $73.00
Item#: PN21864 Mfr Part#: 27506
BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506
Item#: PN21864 Mfr Part#: 27506 Manufacturer: Brandtech

BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506


 

Overview

Class A, USP, certified graduated pipette. Type 2 total delivery pipette only requires setting meniscus one time. In the DIN EN ISO 835 standard, the waiting time has been reduced from 15 to 5 seconds. High contrast blue enamel represents the optimum combination of resistance and readability. Full ring marks at major graduations. Made with BRAND's flexible screen stencils which ensures the volume markings match the calibration marks for enhanced accuracy at all intermediate volumes. Available in all ISO sizes from 1mL to 10mL. Made of AR-GLAS®.

The optimized flow geometry in the tip ensures reliable liquid dispensing from the pipette. The mechanical resilience of the tip and its fire-polished edges ensures a long service life.

All BLAUBRAND® USP graduated pipettes are supplied with a batch number and an accompanying USP batch certificate in the original packaging.

Volumetric instruments according to USP error limits

Companies producing pharmaceutical products for the US market are supervised by US authorities, e.g. the FDA (Food and Drug Administration), and have to meet the requirements of the USP (United States Pharmacopeia). The current USP prescribes in section 31 the use of volumetric instruments with accuracy in accordance to class A of the ASTM standards and list those for volumetric flasks, transfer pipettes and burettes in tables. For graduated pipettes up to and including 10 mL size the error limits are mentioned in the text. BRAND volumetric instruments are manufactured according to the current DIN EN ISO standards. As the construction specifications are differently defined in the DIN EN ISO and ASTM standards, the error limits differ as well. With included USP certificates BRAND confirms for the delivered USP volumetric instruments that the class A error limits according to the USP or, rather, ASTM standards are met.

Every glass volumetric measuring instrument is individually calibrated. Computer-controlled systems ensure maximum precision in a fully automated production line. The final step of this Statistical Process Control is random sampling of finished product according to DIN ISO 3951. The quality management system applied at BRAND, which is certified according to DIN EN ISO 9001, is a combination of process monitoring and random checks with an accepted quality level (AQL) of approximately 0.4.

The batch certificate confirms that ASTM class A error limits required by USP are met. The certificate records the mean value, the standard deviation of the batch and the date of issue (batch number: year of manufacture/batch).

This item is non-returnable/non-refundable

BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506


Class A, USP, Certified Graduated Pipettes

  Volume
   mL
Subdivision
mL
Error limits
± mL
Length
mm
Qty/Pack
Cat. No.
  1
0.01
0.01
360
12
27506
  2
0.02
0.01
360
12
27509
  5
0.05
0.02
360
12
27511
  10
0.1
0.03
360
12
27513
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506
Item#: PN21864 Mfr Part#: 27506 Manufacturer: Brandtech

BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506


 

Overview

Class A, USP, certified graduated pipette. Type 2 total delivery pipette only requires setting meniscus one time. In the DIN EN ISO 835 standard, the waiting time has been reduced from 15 to 5 seconds. High contrast blue enamel represents the optimum combination of resistance and readability. Full ring marks at major graduations. Made with BRAND's flexible screen stencils which ensures the volume markings match the calibration marks for enhanced accuracy at all intermediate volumes. Available in all ISO sizes from 1mL to 10mL. Made of AR-GLAS®.

The optimized flow geometry in the tip ensures reliable liquid dispensing from the pipette. The mechanical resilience of the tip and its fire-polished edges ensures a long service life.

All BLAUBRAND® USP graduated pipettes are supplied with a batch number and an accompanying USP batch certificate in the original packaging.

Volumetric instruments according to USP error limits

Companies producing pharmaceutical products for the US market are supervised by US authorities, e.g. the FDA (Food and Drug Administration), and have to meet the requirements of the USP (United States Pharmacopeia). The current USP prescribes in section 31 the use of volumetric instruments with accuracy in accordance to class A of the ASTM standards and list those for volumetric flasks, transfer pipettes and burettes in tables. For graduated pipettes up to and including 10 mL size the error limits are mentioned in the text. BRAND volumetric instruments are manufactured according to the current DIN EN ISO standards. As the construction specifications are differently defined in the DIN EN ISO and ASTM standards, the error limits differ as well. With included USP certificates BRAND confirms for the delivered USP volumetric instruments that the class A error limits according to the USP or, rather, ASTM standards are met.

Every glass volumetric measuring instrument is individually calibrated. Computer-controlled systems ensure maximum precision in a fully automated production line. The final step of this Statistical Process Control is random sampling of finished product according to DIN ISO 3951. The quality management system applied at BRAND, which is certified according to DIN EN ISO 9001, is a combination of process monitoring and random checks with an accepted quality level (AQL) of approximately 0.4.

The batch certificate confirms that ASTM class A error limits required by USP are met. The certificate records the mean value, the standard deviation of the batch and the date of issue (batch number: year of manufacture/batch).

BrandTech BLAUBRAND, Graduated Pipette, Class AS, USP, Certified, 1mL, 27506


Class A, USP, Certified Graduated Pipettes

  Volume
   mL
Subdivision
mL
Error limits
± mL
Length
mm
Qty/Pack
Cat. No.
  1
0.01
0.01
360
12
27506
  2
0.02
0.01
360
12
27509
  5
0.05
0.02
360
12
27511
  10
0.1
0.03
360
12
27513
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.