phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Edwards ELD500 Remote Control - Wired, D13550100, ELD 500
Item#: PN23589 Mfr Part#: D13550100 Manufacturer: Edwards Vacuum
Condition: New
New Edwards ELD500 Remote Control - Wired, D13550100, ELD 500

Features:
  • For Edwards ELD 500 LEak Detector
  • D13550100
  • Remote Control - Wired
  • Edwards Leak Detection

PRICE: $2,907.00
WEB SAVINGS: $418.00
YOU PAY: $2,489.00
Item#: PN23589 Mfr Part#: D13550100
Edwards ELD500 Remote Control - Wired, D13550100, ELD 500
Item#: PN23589 Mfr Part#: D13550100 Manufacturer: Edwards Vacuum

Edwards ELD500 Leak Detector Remote Control - Wired, D13550100, ELD 500

 

New Edwards ELD 500 Helium Leak Detector Remote Control - Product Overview:


Edwards new ELD500 fully automated leak detector has arrived. To control it remotely, allowing you to test large objects, the ELD500 RC/RC wireless is the perfect accessory. With the Wireless option you can even control up to 10 separate units for production line testing.

Edwards ELD500 Brochure and DataSheet available below.

 

Edwards Leak Detector Available in Three Models: Wet, Dry, Flex


  • WET version with an integrated oil sealed rotary vane pump
  • DRY version with an integrated helium optimised diaphragm pump
  • FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

This item is non-returnable/non-refundable

Edwards ELD500 Remote Control - Wired, D13550100, ELD 500

 

Edwards ELD 500 LEak Detector Remote Control Technical Data:


Dimensions (L x W x H) 210 x 90 x 46 mm
Weight ELD500 RC Wired ca. 0.4 kg
Weight ELD500 RC Wireless ca. 0.5 kg
Type of protection IP 42


Characteristics

Audio alarm at 1 m distance 70 db(A) maximum
Headphone jack stereo 3.5 mm > 2 x 32 Ohm
Range of wireless transmission > 100 m in free field
HF output power +6 dBm (4 mW)
Frequency of wireless transmission 2.4 GHz
Internal memory capacity 64 MB, 32 MB of which is available for recording data
Battery operation time (ELD500 RC Wireless) > 8 hours (depending on battery level)
Display TFT-Touch 1/4 VGA / 3.5‘
‘240 x 320 px, maximum error 4 px
ELD500 RC Wireless charging voltage from power supply 24 V d.c., maximum 0.7 A
ELD500 RC Wired supply voltage from leak detector 24 V d.c., maximum 0.7 A


Environmental Conditions

Only for use within buildings. EN 61010
Permissible ambient temperature (during operation) +5 to +40 ° C
Permissible storage temperature -10 to +60 °C
Maximum relative humidity 80% to 31 °C, linear decreasing 50% at 40 °C
Maximum permissible height above sea level
(during operation)
2000 m




Mains power for wall plug-in power supply

Mains voltages and frequencies 100 - 250 V a.c. 50/60 Hz
Interchangeable blades of mains plug Europe, North America, Japan, UK, China, Australia
Power consumption maximum 30 VA

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Name
Price
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards ELD500 Remote Control - Wired, D13550100, ELD 500
Item#: PN23589 Mfr Part#: D13550100 Manufacturer: Edwards Vacuum

Edwards ELD500 Leak Detector Remote Control - Wired, D13550100, ELD 500

 

New Edwards ELD 500 Helium Leak Detector Remote Control - Product Overview:


Edwards new ELD500 fully automated leak detector has arrived. To control it remotely, allowing you to test large objects, the ELD500 RC/RC wireless is the perfect accessory. With the Wireless option you can even control up to 10 separate units for production line testing.

Edwards ELD500 Brochure and DataSheet available below.

 

Edwards Leak Detector Available in Three Models: Wet, Dry, Flex


  • WET version with an integrated oil sealed rotary vane pump
  • DRY version with an integrated helium optimised diaphragm pump
  • FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Edwards ELD500 Remote Control - Wired, D13550100, ELD 500

 

Edwards ELD 500 LEak Detector Remote Control Technical Data:


Dimensions (L x W x H) 210 x 90 x 46 mm
Weight ELD500 RC Wired ca. 0.4 kg
Weight ELD500 RC Wireless ca. 0.5 kg
Type of protection IP 42


Characteristics

Audio alarm at 1 m distance 70 db(A) maximum
Headphone jack stereo 3.5 mm > 2 x 32 Ohm
Range of wireless transmission > 100 m in free field
HF output power +6 dBm (4 mW)
Frequency of wireless transmission 2.4 GHz
Internal memory capacity 64 MB, 32 MB of which is available for recording data
Battery operation time (ELD500 RC Wireless) > 8 hours (depending on battery level)
Display TFT-Touch 1/4 VGA / 3.5‘
‘240 x 320 px, maximum error 4 px
ELD500 RC Wireless charging voltage from power supply 24 V d.c., maximum 0.7 A
ELD500 RC Wired supply voltage from leak detector 24 V d.c., maximum 0.7 A


Environmental Conditions

Only for use within buildings. EN 61010
Permissible ambient temperature (during operation) +5 to +40 ° C
Permissible storage temperature -10 to +60 °C
Maximum relative humidity 80% to 31 °C, linear decreasing 50% at 40 °C
Maximum permissible height above sea level
(during operation)
2000 m




Mains power for wall plug-in power supply

Mains voltages and frequencies 100 - 250 V a.c. 50/60 Hz
Interchangeable blades of mains plug Europe, North America, Japan, UK, China, Australia
Power consumption maximum 30 VA

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Name
Price
Name
Price
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.