Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000, ELD 500
Item#: PN23590 Mfr Part#: D13530000 Manufacturer: Edwards Vacuum
Condition: New In Stock
New Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000, ELD 500

Features:
  • Edwards ELD 500 Wet
  • D13530000
  • Bench Top Leak Detectors
  • FULL 18-MONTH WARRANTY!

PRICE: $29,083.00
WEB SAVINGS: $6,398.14
YOU PAY: $22,684.86
Item#: PN23590 Mfr Part#: D13530000
Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000, ELD 500
Item#: PN23590 Mfr Part#: D13530000 Manufacturer: Edwards Vacuum

Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000, ELD 500

 

A separate backing pump is required for operation, and is not included with the ELD500

 

New Edwards ELD 500 Flex - Product Overview:


The ELD500 precision leak detector is designed for fast, accurate leak detection in a wide range of applications, fully mobile and with an easy to control interface. Featuring with low energy consumption, extended warranty and even longer life ion source, Edwards ELD500 leak detector ensures exceptional low cost of ownership with no compromise on performance.

Available in three variants: FLEX, WET and DRY, Edwards ELD500 leak detector is versatile. All models feature a rugged turbomolecular pump optimised for the rigours of portable leak detection, ideal across all applications.

Edwards ELD500 Brochure and DataSheet available below.

 

Edwards Leak Detector Available in Three Models: Wet, Dry, Flex


  • WET version with an integrated oil sealed rotary vane pump
  • DRY version with an integrated helium optimised diaphragm pump
  • FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump

 


New Edwards ELD 500 Flex Offer the Following Additional Features:


  • FLEXIBLE REMOTE CONTROL OPTIONS Colour touch screen control with local graphical display and audible leak detection. Wireless models allow simultaneous control of up to 10 leak detectors.

  • MOBILE SOLUTION Low weight and integrated carry handles which allow it to be bench top or trolley mounted.

  • HIGH SENSITIVITY Measurement of leaks for Helium of <5x10-12mbar ls-1 in vacuum mode and <7x10-9mbar ls-1 in sniffer mode.

  • PARTIAL FLOW KIT Allows effective pump down of large of contaminate flows compatible with WET and FLEX variants.

  • ACCURATE PIN-POINTING OF LEAKS Standard sniffer line enables operation up to 4m from the ELD500. Longer sniffer lines of up to 50m can be used with the sniffer extender interface.

  • LONG TERM STABILITY Ensured by class leading 180° mass spectrometer.

 

Edwards ELD500 Series Section:


Edwards ELD 500 Wet Section, D13530000

 

Edwards ELD500 Series Dimensions:


Edwards ELD 500 Flex Dimensions, D13530000


Click Here for Edwards ELD 500 Manual

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Flex Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000

 

Edwards ELD500 Technical Data:


Edwards ELD 500 Wet Technical Data, D13530000


Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Flex Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Name
Price
Item#:
PN23589
Mfr Part#:
D13550100
$2,489.00
Item#:
PN23592
Mfr Part#:
D13550300
$2,278.00
Item#:
PN23593
Mfr Part#:
14008
$1,899.00
Item#:
PN23594
Mfr Part#:
D13550400
$4,699.00
Item#:
PN23612
Mfr Part#:
D13550630
$1,895.00
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000, ELD 500
Item#: PN23590 Mfr Part#: D13530000 Manufacturer: Edwards Vacuum

Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000, ELD 500

 

A separate backing pump is required for operation, and is not included with the ELD500

 

New Edwards ELD 500 Flex - Product Overview:


The ELD500 precision leak detector is designed for fast, accurate leak detection in a wide range of applications, fully mobile and with an easy to control interface. Featuring with low energy consumption, extended warranty and even longer life ion source, Edwards ELD500 leak detector ensures exceptional low cost of ownership with no compromise on performance.

Available in three variants: FLEX, WET and DRY, Edwards ELD500 leak detector is versatile. All models feature a rugged turbomolecular pump optimised for the rigours of portable leak detection, ideal across all applications.

Edwards ELD500 Brochure and DataSheet available below.

 

Edwards Leak Detector Available in Three Models: Wet, Dry, Flex


  • WET version with an integrated oil sealed rotary vane pump
  • DRY version with an integrated helium optimised diaphragm pump
  • FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump

 


New Edwards ELD 500 Flex Offer the Following Additional Features:


  • FLEXIBLE REMOTE CONTROL OPTIONS Colour touch screen control with local graphical display and audible leak detection. Wireless models allow simultaneous control of up to 10 leak detectors.

  • MOBILE SOLUTION Low weight and integrated carry handles which allow it to be bench top or trolley mounted.

  • HIGH SENSITIVITY Measurement of leaks for Helium of <5x10-12mbar ls-1 in vacuum mode and <7x10-9mbar ls-1 in sniffer mode.

  • PARTIAL FLOW KIT Allows effective pump down of large of contaminate flows compatible with WET and FLEX variants.

  • ACCURATE PIN-POINTING OF LEAKS Standard sniffer line enables operation up to 4m from the ELD500. Longer sniffer lines of up to 50m can be used with the sniffer extender interface.

  • LONG TERM STABILITY Ensured by class leading 180° mass spectrometer.

 

Edwards ELD500 Series Section:


Edwards ELD 500 Wet Section, D13530000

 

Edwards ELD500 Series Dimensions:


Edwards ELD 500 Flex Dimensions, D13530000


Click Here for Edwards ELD 500 Manual

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Flex Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Edwards ELD500 Flex Portable Leak Detector With Connections For External Backing Pump, 100-120V 60Hz, D13530000

 

Edwards ELD500 Technical Data:


Edwards ELD 500 Wet Technical Data, D13530000


Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Flex Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.