Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710
Item#: PN23701 Mfr Part#: D40R0S0MB710 Manufacturer: Pfeiffer Vacuum
Condition: Discontinued
Discontinued Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710

Features:
  • High User Flexibility w/Emphasis on Simplified Operability
  • Includes a Rotary Vane Backing Pump
  • Incorporates Graphic Touch Screen User Interface
  • Utilizes a DN 40 ISO-KF Inlet Flange

This product has been discontinued and is no longer available for sale
Item#: PN23701 Mfr Part#: D40R0S0MB710
Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710
Item#: PN23701 Mfr Part#: D40R0S0MB710 Manufacturer: Pfeiffer Vacuum

Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710

 

Pfeiffer/Adixen ASM 192T - Product Series Overview:


The ASM 182/192 series of helium leak detectors includes the most up-to-date evolutions of Adixen leak detectors, thousands of which are utilized in successful daily operation throughout the world in various applications. These include applications within the automotive, chemical and mechanical, electrical, electronics and packaging industries, as well as in quality control and maintenance of semiconductor processing systems,  blister testing in the pharmaceutical industry, among other uses. This series of leak detectors offer unique features including high sensitivity (5 x 10^(-12) mbar l/s) and fast response time while in spraying mode.

Additionally, the ASM 182/192 series is extremely flexible with an emphasis on simplified operability and a user-friendly interface. Automatic operation is provided throughout the range of processes, including atmospheric sniffer tests, gas line and tube testing, large gross leak mode and ultra-sensitive vacuum fine leak mode, readily available basic functions, combined digital and analog display, as well as advanced functions for convenience.

Among this series of Pfeiffer Adixen leak detectors, the 192 T is a standout leading innovation. It is a console leak detector featuring the option of one or two dry pumps with a backing capacity of 25 m^3/h and 50 m^3/h, respectively. The product is ideal for industrial applications and environments involving large, complex systems with little capacity for error. The Adixen 192 T is likewise a reliable leak detector option for severe environments and circumstances. Its high helium pumping speed of 20 liters per second allows for a quickened response time, and the application arrives with an available test chamber accessory for user convenience.

Pfeiffer/Adixen ASM 192 T2D+ Front panel, D30R0S0MB710

 

Pfeiffer/Adixen ASM 192 T Features:


  • Powerful rotary vane pump with 20 m3/h backing capacity
  • 4.4 l/s helium pumping speed
  • 110/130 V operating voltage
  • US power cable
  • Voice synthesizer in English
  • Remote control in mbar l/s

 

A Brief Description of the Science and Processes Involved in Helium Leak Detection:


Leak detection utilizing helium has a complex history dating back to the first half of the twentieth century and is used in a variety of processes and industries. Helium is used as the preferred tracer gas for eliminating leaks for a variety of reasons, including its non-flammability, non-toxicity, and inexpensiveness relative to other gases. Likewise, its inert state and small atomic size (helium has an atomic mass unit of 4 - second only to hydrogen, which has an AMU of 2) allows the gas to pass through leaks with ease. Unlike hydrogen however, helium is stable and non-explosive, providing a better alternative to be used in leak detection processes.

Utilizing the beneficial qualities of helium, a Helium Leak Detector pumps molecules of the gas into the device's analyzer cell through the use of vacuum pumps. The analyzer cell works on the principle of mass spectroscopy and measures the gas's partial pressure, displayed on the device's spectrometer. A higher reading indicates that a leak may be present, as represented by the quantity and concentration of helium molecules that have passed through a given space, as analyzed by the device. The leak detector converts this partial pressure of molecules into a flow rate. Helium leak detectors are known to be extremely precise and exhibit unparalleled accuracy in detecting leaks.

 

Pfeiffer/Adixen 192 T Dimensions:


Pfeiffer/Adixen ASM 192 T2D+ Dimension, D30R0S0MB710


Click Here for Pfeiffer/Adixen ASM 192 T Manual

Click Here for Pfeiffer/Adixen ASM 192 T Data Sheet


A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710

 

Pfeiffer ASM 192T Technical Data


Backing pump with oil sealed backing pump
Backing pump capacity 20 m³/h | 11.77 cfm | 333.33 l/min
Detectable gases 4He
Dimensions (L x W x H) 594 x 692 x 933 mm | 23.39 x 27.24 x 36.73 inch
Flange (in) DN 40 ISO-KF
I/O interfaces Digital inputs (Start, Vent, Calibration…); Digital outputs (Test modes, cycle in progress, helium signal above reject set point…); Analog outputs (Helium signal log, Inlet pressure)
Language English
Mains cable Yes, US power cable  
Minimum detectable leak rate for helium (sniffing leak detection) 1 · 10-8 Pa m3/s | 7.5 · 10-8 Torr l/s | 1 · 10-7 mbar l/s
Minimum detectable leak rate for helium (vacuum leak detection) 5 · 10-13 Pa m³/s  
Noise level 54 dB(A)
Power consumption max. 1300 W
Pumping speed for He 4.4 l/s
Sound pressure level 54 dB(A)
Start-up time (20°C) with calibration 4.5 min
Start-up time (20°C) without calibration 3 min
Supply 110 – 130 V, 50/60 Hz
Test method Vacuum and sniffing leak detection
Type High Performance - Compact
User interface Graphic color touch screen
Weight 125 kg | 275.57 lb

Click Here for Pfeiffer/Adixen ASM 192 T Manual

Click Here for Pfeiffer/Adixen ASM 192 T Data Sheet

A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710
Item#: PN23701 Mfr Part#: D40R0S0MB710 Manufacturer: Pfeiffer Vacuum

Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710

 

Pfeiffer/Adixen ASM 192T - Product Series Overview:


The ASM 182/192 series of helium leak detectors includes the most up-to-date evolutions of Adixen leak detectors, thousands of which are utilized in successful daily operation throughout the world in various applications. These include applications within the automotive, chemical and mechanical, electrical, electronics and packaging industries, as well as in quality control and maintenance of semiconductor processing systems,  blister testing in the pharmaceutical industry, among other uses. This series of leak detectors offer unique features including high sensitivity (5 x 10^(-12) mbar l/s) and fast response time while in spraying mode.

Additionally, the ASM 182/192 series is extremely flexible with an emphasis on simplified operability and a user-friendly interface. Automatic operation is provided throughout the range of processes, including atmospheric sniffer tests, gas line and tube testing, large gross leak mode and ultra-sensitive vacuum fine leak mode, readily available basic functions, combined digital and analog display, as well as advanced functions for convenience.

Among this series of Pfeiffer Adixen leak detectors, the 192 T is a standout leading innovation. It is a console leak detector featuring the option of one or two dry pumps with a backing capacity of 25 m^3/h and 50 m^3/h, respectively. The product is ideal for industrial applications and environments involving large, complex systems with little capacity for error. The Adixen 192 T is likewise a reliable leak detector option for severe environments and circumstances. Its high helium pumping speed of 20 liters per second allows for a quickened response time, and the application arrives with an available test chamber accessory for user convenience.

Pfeiffer/Adixen ASM 192 T2D+ Front panel, D30R0S0MB710

 

Pfeiffer/Adixen ASM 192 T Features:


  • Powerful rotary vane pump with 20 m3/h backing capacity
  • 4.4 l/s helium pumping speed
  • 110/130 V operating voltage
  • US power cable
  • Voice synthesizer in English
  • Remote control in mbar l/s

 

A Brief Description of the Science and Processes Involved in Helium Leak Detection:


Leak detection utilizing helium has a complex history dating back to the first half of the twentieth century and is used in a variety of processes and industries. Helium is used as the preferred tracer gas for eliminating leaks for a variety of reasons, including its non-flammability, non-toxicity, and inexpensiveness relative to other gases. Likewise, its inert state and small atomic size (helium has an atomic mass unit of 4 - second only to hydrogen, which has an AMU of 2) allows the gas to pass through leaks with ease. Unlike hydrogen however, helium is stable and non-explosive, providing a better alternative to be used in leak detection processes.

Utilizing the beneficial qualities of helium, a Helium Leak Detector pumps molecules of the gas into the device's analyzer cell through the use of vacuum pumps. The analyzer cell works on the principle of mass spectroscopy and measures the gas's partial pressure, displayed on the device's spectrometer. A higher reading indicates that a leak may be present, as represented by the quantity and concentration of helium molecules that have passed through a given space, as analyzed by the device. The leak detector converts this partial pressure of molecules into a flow rate. Helium leak detectors are known to be extremely precise and exhibit unparalleled accuracy in detecting leaks.

 

Pfeiffer/Adixen 192 T Dimensions:


Pfeiffer/Adixen ASM 192 T2D+ Dimension, D30R0S0MB710


Click Here for Pfeiffer/Adixen ASM 192 T Manual

Click Here for Pfeiffer/Adixen ASM 192 T Data Sheet


A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Pfeiffer Adixen ASM 192 T Helium Leak Detector, 20 m3/h Pumping Speed, 110/130 V, US Power Cable, D40R0S0MB710

 

Pfeiffer ASM 192T Technical Data


Backing pump with oil sealed backing pump
Backing pump capacity 20 m³/h | 11.77 cfm | 333.33 l/min
Detectable gases 4He
Dimensions (L x W x H) 594 x 692 x 933 mm | 23.39 x 27.24 x 36.73 inch
Flange (in) DN 40 ISO-KF
I/O interfaces Digital inputs (Start, Vent, Calibration…); Digital outputs (Test modes, cycle in progress, helium signal above reject set point…); Analog outputs (Helium signal log, Inlet pressure)
Language English
Mains cable Yes, US power cable  
Minimum detectable leak rate for helium (sniffing leak detection) 1 · 10-8 Pa m3/s | 7.5 · 10-8 Torr l/s | 1 · 10-7 mbar l/s
Minimum detectable leak rate for helium (vacuum leak detection) 5 · 10-13 Pa m³/s  
Noise level 54 dB(A)
Power consumption max. 1300 W
Pumping speed for He 4.4 l/s
Sound pressure level 54 dB(A)
Start-up time (20°C) with calibration 4.5 min
Start-up time (20°C) without calibration 3 min
Supply 110 – 130 V, 50/60 Hz
Test method Vacuum and sniffing leak detection
Type High Performance - Compact
User interface Graphic color touch screen
Weight 125 kg | 275.57 lb

Click Here for Pfeiffer/Adixen ASM 192 T Manual

Click Here for Pfeiffer/Adixen ASM 192 T Data Sheet

A&J Vacuum Services offers full repair/service of Pfeiffer ASM 192 T Helium Leak Detectors, along with all other brands of helium leak detectors offered on our website. AJVS also services Pfeiffer turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.