phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Edwards ELD500 Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500
Item#: PN24477 Mfr Part#: D13550631 Manufacturer: Edwards Vacuum
Condition: New In Stock
New Edwards ELD500 Helium Leak Detector Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500

Features:
  • For Edwards ELD 500 to nXDS pumps
  • D13550631
  • OEM Cable
  • Edwards Leak Detection

PRICE: $263.00
WEB SAVINGS: $23.01
YOU PAY: $239.99
Item#: PN24477 Mfr Part#: D13550631
Edwards ELD500 Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500
Item#: PN24477 Mfr Part#: D13550631 Manufacturer: Edwards Vacuum

Edwards ELD500 Helium Leak Detector Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500

 

Edwards nXDS Series Auto-Start Cable - Product Overview:


Edwards ELD 500 Auto-Start cable allows automatic start of the nXDS series pump coupled with ELD 500 Helium Leak detectors.

Edwards Auto-Start Cable D13550631 works with the pumps listed below.

  • ELD 500 to nXDS 6i Scroll Pumps
  • ELD 500 to nXDS 10i Scroll Pumps
  • ELD 500 to nXDS 15i Scroll Pumps
  • ELD 500 to nXDS 20i Scroll Pumps
The Edwards ELD500 auto-start cable (D13550631) allows the electrical start and stop of a connected Edwards nXDS pump. This will start and stop the connected pump with the
power on and off of the ELD500. This function needs to be enabled in the ELD500
software: Settings > Interfaces > Define PLC outputs > define the 5, 6 and 7 PLC outputs to CLOSE.

Edwards ELD500 Brochure and DataSheet available below.

 

Edwards ELD 500 Leak Detector Available in Three Models: Wet, Dry, Flex


  • WET version with an integrated oil sealed rotary vane pump
  • DRY version with an integrated helium optimised diaphragm pump
  • FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Edwards ELD500 Helium Leak Detector Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500

 

Edwards nXDS Series Auto-Start Cable - Product Overview:


The Edwards ELD500 auto-start cable (D13550631) allows the electrical start and stop of a connected Edwards nXDS pump. This will start and stop the connected pump with the
power on and off of the ELD500. This function needs to be enabled in the ELD500
software: Settings > Interfaces > Define PLC outputs > define the 5, 6 and 7 PLC outputs to CLOSE.

Edwards Auto-Start Cable D13550631 works with the pumps listed below.

  • ELD 500 to nXDS 6i Scroll Pumps
  • ELD 500 to nXDS 10i Scroll Pumps
  • ELD 500 to nXDS 15i Scroll Pumps
  • ELD 500 to nXDS 20i Scroll Pumps

 

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards ELD500 Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500
Item#: PN24477 Mfr Part#: D13550631 Manufacturer: Edwards Vacuum

Edwards ELD500 Helium Leak Detector Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500

 

Edwards nXDS Series Auto-Start Cable - Product Overview:


Edwards ELD 500 Auto-Start cable allows automatic start of the nXDS series pump coupled with ELD 500 Helium Leak detectors.

Edwards Auto-Start Cable D13550631 works with the pumps listed below.

  • ELD 500 to nXDS 6i Scroll Pumps
  • ELD 500 to nXDS 10i Scroll Pumps
  • ELD 500 to nXDS 15i Scroll Pumps
  • ELD 500 to nXDS 20i Scroll Pumps
The Edwards ELD500 auto-start cable (D13550631) allows the electrical start and stop of a connected Edwards nXDS pump. This will start and stop the connected pump with the
power on and off of the ELD500. This function needs to be enabled in the ELD500
software: Settings > Interfaces > Define PLC outputs > define the 5, 6 and 7 PLC outputs to CLOSE.

Edwards ELD500 Brochure and DataSheet available below.

 

Edwards ELD 500 Leak Detector Available in Three Models: Wet, Dry, Flex


  • WET version with an integrated oil sealed rotary vane pump
  • DRY version with an integrated helium optimised diaphragm pump
  • FLEX version without a primary pump, ideal for trolley mounting along with a larger primary pump such as an Edwards nXDS scroll pump

Click Here for Edwards ELD 500 Leak Detection Data Sheet

Click Here for Edwards ELD 500 Product Brochure


A&J Vacuum services and repairs Edwards ELD 500 Leak Detector, along with all other Edwards Vacuum Leak Detectors available on our website. Please contact us for information concerning our service and repair program, or click http://www.ajvs.com/service.php to access our Services page. We likewise offer Emergency service and repair upon request. For additional information, Please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier and business partner.

Edwards ELD500 Helium Leak Detector Auto-Start Cable, for nXDS Series Pumps, D13550631, ELD 500

 

Edwards nXDS Series Auto-Start Cable - Product Overview:


The Edwards ELD500 auto-start cable (D13550631) allows the electrical start and stop of a connected Edwards nXDS pump. This will start and stop the connected pump with the
power on and off of the ELD500. This function needs to be enabled in the ELD500
software: Settings > Interfaces > Define PLC outputs > define the 5, 6 and 7 PLC outputs to CLOSE.

Edwards Auto-Start Cable D13550631 works with the pumps listed below.

  • ELD 500 to nXDS 6i Scroll Pumps
  • ELD 500 to nXDS 10i Scroll Pumps
  • ELD 500 to nXDS 15i Scroll Pumps
  • ELD 500 to nXDS 20i Scroll Pumps

 

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.