phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Leybold Replacement Anode Modul, Penningvac PTR 90N, 225N, 237N, E20028712V02 / 20028711V02
Item#: PN24505 Mfr Part#: E20028712V02 Manufacturer: Leybold
Condition: New
New Leybold Replacement Anode Modul, Penningvac PTR 90N, 225N, 237N, E20028712V02 / 20028711V02

Features:

PRICE: $375.00
WEB SAVINGS: $75.01
YOU PAY: $299.99
Item#: PN24505 Mfr Part#: E20028712V02
Leybold Replacement Anode Modul, Penningvac PTR 90N, 225N, 237N, E20028712V02 / 20028711V02
Item#: PN24505 Mfr Part#: E20028712V02 Manufacturer: Leybold

Leybold Replacement Anode Modul, Penningvac PTR 90N, 225N, 237N, E20028712V02 / 20028711V02 

 

E20028712V02 is the direct replacement for 20028711V02.

 

Leybold PTR 90 N Penningvac Overview:


This is a Anode ring for the Penningvac PTR 90 N, 225 N, 237 N

The Leybold Penningvac PTR 90N Vacuum Gauge  head combines the cold cathode ionization principle with the Pirani measurement system and mey be operated with modern display and operation instruments.

The Leybold PTR 90 transmeters offer the capability of single port pressure measurement in the range from atmosphere to 10-9 mbar.

The Leybold Penningvac PTR 90N 230088V02 Transmiters are equipped with rugged cold cathode measurement cell for integration within programmable systems. They offer a high level of reproducibility combined with low tendency to collect contamination even in argon operation.

 

Leybold PTR 90 N Penningvac, 230070V02

 

Leybold PTR 90 Sensor Technology


PTR 90 N transmiter contain two separate sensor elements. The MEMS Pirani (MEMS = Micro-Electro-MechanicalSystem) sensor element is based on measurement of thermal conductivity. The MEMS Pirani sensor consists of a silicon chip with a heated resistive element forming one surface of a cavity.

A cover on top of the chip forms the other surface of the cavity. Due to the geometry of the sensor, convection cannot take place within the cavity and consequently the sensor is insensitive to mounting position. Gas molecules are passed by diffusion only to the heated element where the heat loss of the gas is measured. The cold cathode inverted magnetron utilizes a high voltage anode, cathode and a permanent magnet.

Electrons are accelerated towards the anode and will ionize molecules by collision. The magnetic field deflects the electrons, causing them to spiral as they move across the magnetic field to the anode. This spiraling movement increases the opportunity for them to encounter and ionize the molecules. The ionization of the molecules creates an electric current as a function of the pressure. Both sensor elements are very robust and can withstand high G-forces and fast inrushes of air.

 

Leybold PTR90 N Dimensions:


Leybold PTR 90N Penningvac, DN 25 ISO-KF, 230070V02

 


Click Here for PenningVac PTR90N Trnasmitter Operating Manual

Click Here for Leybold Vacuum Measurement Active Sensors Broshure


A&J Vacuum services and repairs Leybold Scroll Vacuum Pumps, Leybold Turbo Pump repair along with all other Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

This item is non-returnable/non-refundable
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Leybold Replacement Anode Modul, Penningvac PTR 90N, 225N, 237N, E20028712V02 / 20028711V02
Item#: PN24505 Mfr Part#: E20028712V02 Manufacturer: Leybold

Leybold Replacement Anode Modul, Penningvac PTR 90N, 225N, 237N, E20028712V02 / 20028711V02 

 

E20028712V02 is the direct replacement for 20028711V02.

 

Leybold PTR 90 N Penningvac Overview:


This is a Anode ring for the Penningvac PTR 90 N, 225 N, 237 N

The Leybold Penningvac PTR 90N Vacuum Gauge  head combines the cold cathode ionization principle with the Pirani measurement system and mey be operated with modern display and operation instruments.

The Leybold PTR 90 transmeters offer the capability of single port pressure measurement in the range from atmosphere to 10-9 mbar.

The Leybold Penningvac PTR 90N 230088V02 Transmiters are equipped with rugged cold cathode measurement cell for integration within programmable systems. They offer a high level of reproducibility combined with low tendency to collect contamination even in argon operation.

 

Leybold PTR 90 N Penningvac, 230070V02

 

Leybold PTR 90 Sensor Technology


PTR 90 N transmiter contain two separate sensor elements. The MEMS Pirani (MEMS = Micro-Electro-MechanicalSystem) sensor element is based on measurement of thermal conductivity. The MEMS Pirani sensor consists of a silicon chip with a heated resistive element forming one surface of a cavity.

A cover on top of the chip forms the other surface of the cavity. Due to the geometry of the sensor, convection cannot take place within the cavity and consequently the sensor is insensitive to mounting position. Gas molecules are passed by diffusion only to the heated element where the heat loss of the gas is measured. The cold cathode inverted magnetron utilizes a high voltage anode, cathode and a permanent magnet.

Electrons are accelerated towards the anode and will ionize molecules by collision. The magnetic field deflects the electrons, causing them to spiral as they move across the magnetic field to the anode. This spiraling movement increases the opportunity for them to encounter and ionize the molecules. The ionization of the molecules creates an electric current as a function of the pressure. Both sensor elements are very robust and can withstand high G-forces and fast inrushes of air.

 

Leybold PTR90 N Dimensions:


Leybold PTR 90N Penningvac, DN 25 ISO-KF, 230070V02

 


Click Here for PenningVac PTR90N Trnasmitter Operating Manual

Click Here for Leybold Vacuum Measurement Active Sensors Broshure


A&J Vacuum services and repairs Leybold Scroll Vacuum Pumps, Leybold Turbo Pump repair along with all other Turbo Pumps available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier.

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.