The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Thermo Scientific LTQ Velos Pro Mass Spectometer.
Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.
Leybold TW250 Turbo Pumps are suitable for pumping air and clean gases. Leybold Turbodrive TD400 is being used to controll TW250 Turbo Pump, TD 400 Controller is mounted at the base of the Thermo Fisher Turbo Pump.
The Leybold TW 250/20/40 TI / 800160V0020C pump comprises essentially a multi-stage rotor with the stator group, and the drive. The first section of the rotor are two turbomolecular pump stages while the second section represents a Holweck stage.
The Holweck pumping stage increases the permissible forevacuum pressure level markedly when compared with the classical turbomolecular pump. The pumps have gas inlets into the turbo stages, the triple-inlet pumps have a third gas inlet into the Holweck stage. The two triple-inlet pumps are very similar, they differ mainly in the Holweck stage and the operating speed.
Leybold TW250/200/40 UHV was also knows as Oerlikon TW250/200/40 and Thermo 00108-01-00024
High-Vacuum Connections: depends on customized housing variants
A&J Vacuum also repair / rebuild and service Oerlikon Turbo TW250/200/40 Turbo Pump repair and TW part #800001856 Turbo Pumps along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Mass Spectrometers Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Thermo Scientific LTQ Velos Pro Mass Spectometer.
Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.
Leybold TW250 Turbo Pumps are suitable for pumping air and clean gases. Leybold Turbodrive TD400 is being used to controll TW250 Turbo Pump, TD 400 Controller is mounted at the base of the Thermo Fisher Turbo Pump.
The Leybold TW 250/20/40 TI / 800160V0020C pump comprises essentially a multi-stage rotor with the stator group, and the drive. The first section of the rotor are two turbomolecular pump stages while the second section represents a Holweck stage.
The Holweck pumping stage increases the permissible forevacuum pressure level markedly when compared with the classical turbomolecular pump. The pumps have gas inlets into the turbo stages, the triple-inlet pumps have a third gas inlet into the Holweck stage. The two triple-inlet pumps are very similar, they differ mainly in the Holweck stage and the operating speed.
Leybold TW250/200/40 UHV was also knows as Oerlikon TW250/200/40 and Thermo 00108-01-00024
High-Vacuum Connections: depends on customized housing variants
A&J Vacuum also repair / rebuild and service Oerlikon Turbo TW250/200/40 Turbo Pump repair and TW part #800001856 Turbo Pumps along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Mass Spectrometers Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.