phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Leybold TW 250/200/40 Turbo Pump Leybold P/N 800160V0020C
Item#: PN24582 Mfr Part#: 800160V0020C Manufacturer: Leybold
Condition: Remanufactured Call us for Availability
Remanufactured Fully Re-manufactured Leybold TW 250/200/40 Cartridge Turbo Pump Leybold P/N 800160V0020C TW250/200/40

Features:
  • Leybold P/N 800160V0020C
  • Fully Remanufactured
  • 12-Months warranty
  • Cartridge Only

Price upon request
Item#: PN24582 Mfr Part#: 800160V0020C
Leybold TW 250/200/40 Turbo Pump Leybold P/N 800160V0020C
Item#: PN24582 Mfr Part#: 800160V0020C Manufacturer: Leybold

Fully Re-manufactured Leybold TW 250/200/40 Cartridge Turbo Pump Leybold P/N 800160V0020C TW250/200/40 / Thermo 00108-01-00024

 

Leybold Oerlikon TW 250/200/40 / 800160V0020C Cartridge Overview:


The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Thermo Scientific LTQ Velos Pro Mass Spectometer.

Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.

Leybold TW250 Turbo Pumps are suitable for pumping air and clean gases. Leybold Turbodrive TD400 is being used to controll TW250 Turbo Pump, TD 400 Controller is mounted at the base of the Thermo Fisher Turbo Pump.

The Leybold TW 250/20/40 TI / 800160V0020C pump comprises essentially a multi-stage rotor with the stator group, and the drive. The first section of the rotor are two turbomolecular pump stages while the second section represents a Holweck stage.

The Holweck pumping stage increases the permissible forevacuum pressure level markedly when compared with the classical turbomolecular pump. The pumps have gas inlets into the turbo stages, the triple-inlet pumps have a third gas inlet into the Holweck stage. The two triple-inlet pumps are very similar, they differ mainly in the Holweck stage and the operating speed.

Leybold TW250/200/40 UHV was also knows as Oerlikon TW250/200/40 and Thermo 00108-01-00024

High-Vacuum Connections: depends on customized housing variants


A&J Vacuum also repair / rebuild and service Oerlikon Turbo TW250/200/40 Turbo Pump repair and TW part #800001856 Turbo Pumps  along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

This item is non-returnable/non-refundable

Fully Re-manufactured Leybold TW 250/200/40 Cartridge Turbo Pump Leybold P/N 800160V0020C TW 250/200/40 TI

 

Leybold Oerlikon TW 250/200/40 / 800160V0020C Cartridge Overview:


The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Mass Spectrometers Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Leybold TW 250/200/40 Turbo Pump Leybold P/N 800160V0020C
Item#: PN24582 Mfr Part#: 800160V0020C Manufacturer: Leybold

Fully Re-manufactured Leybold TW 250/200/40 Cartridge Turbo Pump Leybold P/N 800160V0020C TW250/200/40 / Thermo 00108-01-00024

 

Leybold Oerlikon TW 250/200/40 / 800160V0020C Cartridge Overview:


The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Thermo Scientific LTQ Velos Pro Mass Spectometer.

Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.

Leybold TW250 Turbo Pumps are suitable for pumping air and clean gases. Leybold Turbodrive TD400 is being used to controll TW250 Turbo Pump, TD 400 Controller is mounted at the base of the Thermo Fisher Turbo Pump.

The Leybold TW 250/20/40 TI / 800160V0020C pump comprises essentially a multi-stage rotor with the stator group, and the drive. The first section of the rotor are two turbomolecular pump stages while the second section represents a Holweck stage.

The Holweck pumping stage increases the permissible forevacuum pressure level markedly when compared with the classical turbomolecular pump. The pumps have gas inlets into the turbo stages, the triple-inlet pumps have a third gas inlet into the Holweck stage. The two triple-inlet pumps are very similar, they differ mainly in the Holweck stage and the operating speed.

Leybold TW250/200/40 UHV was also knows as Oerlikon TW250/200/40 and Thermo 00108-01-00024

High-Vacuum Connections: depends on customized housing variants


A&J Vacuum also repair / rebuild and service Oerlikon Turbo TW250/200/40 Turbo Pump repair and TW part #800001856 Turbo Pumps  along with all other Oerlikon Leybold Vacuum Rotary Vane Pumps, Oerlikon Dry Scroll Pump repair, Oerlikon Leybold Leak Detector Repair and all other Leybold Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Fully Re-manufactured Leybold TW 250/200/40 Cartridge Turbo Pump Leybold P/N 800160V0020C TW 250/200/40 TI

 

Leybold Oerlikon TW 250/200/40 / 800160V0020C Cartridge Overview:


The Leybold TW250/200/40 Cartride Turbo Pump is a special Turbo Pump designed for Mass Spectrometers Instruments to evacuate up to three vacuum chambers. Thermo p/n 00108-01-00024 TW 250/200/40 have a mounting housing and is designed to be integrated into a Mass Spec system.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.