Edwards iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A533-53-945
Item#: PN00253 Mfr Part#: A533-53-945 Manufacturer: Edwards Vacuum
Condition: Remanufactured In Stock
Remanufactured Edwards Vacuum iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A53353945

Features:
  • Pumping Speed: 84 m3h-1 / 49 cfm
  • Ultimate Vacuum: 3 x 10-2 mbar
  • Motor Power: 2.2 kW
  • Outlet Flange: NW 40

PRICE: $11,293.95
WEB SAVINGS: $3,053.95
YOU PAY: $8,240.00
Item#: PN00253 Mfr Part#: A533-53-945
Edwards iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A533-53-945
Item#: PN00253 Mfr Part#: A533-53-945 Manufacturer: Edwards Vacuum

Edwards Vacuum iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A53353945

 

Edwards iL 70 Overview:


The iL system operates at pressures between atmospheric and ultimate vacuum with no lubricating or sealing fluid in the pumping chambers. This ensures a clean pumping system without back-migration of oil into the system being evacuated.

The iL 70 system has an LCDP70 dry pump.

The LCDP70 has enclosed, water-cooled motors. The iL system is therefore suitable for applications in clean environments where fan cooling is unacceptable.

The iL system is designed to operate as a sealed unit, chemicals passing through the pump being contained within the internal volume and separated from the external environment by a mechanical barrier. This barrier is made up of a number of components of different materials, chosen to be resistant to attack by chemicals usually found in clean applications.

 

Edwards iL 70 Dimensions:


Edwards iL 70, A53353945


Click Here for Edwards iL 70 Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards Vacuum iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A53353945

 

Edwards iL 70 Technical Data:


Pumping Speed: 84 m3h-1 / 49 cfm
Ultimate Vacuum: 3 x 10-2 mbar
Motor Power: 2.2 kW
Inlet Flange: ISO 63
Outlet Flange: NW 40
Weight: 557 lbs

Click Here for Edwards iL 70 Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A533-53-945
Item#: PN00253 Mfr Part#: A533-53-945 Manufacturer: Edwards Vacuum

Edwards Vacuum iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A53353945

 

Edwards iL 70 Overview:


The iL system operates at pressures between atmospheric and ultimate vacuum with no lubricating or sealing fluid in the pumping chambers. This ensures a clean pumping system without back-migration of oil into the system being evacuated.

The iL 70 system has an LCDP70 dry pump.

The LCDP70 has enclosed, water-cooled motors. The iL system is therefore suitable for applications in clean environments where fan cooling is unacceptable.

The iL system is designed to operate as a sealed unit, chemicals passing through the pump being contained within the internal volume and separated from the external environment by a mechanical barrier. This barrier is made up of a number of components of different materials, chosen to be resistant to attack by chemicals usually found in clean applications.

 

Edwards iL 70 Dimensions:


Edwards iL 70, A53353945


Click Here for Edwards iL 70 Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards Vacuum iL 70 Dry Vacuum Pumping System, 220 V, 50/60 Hz, A53353945

 

Edwards iL 70 Technical Data:


Pumping Speed: 84 m3h-1 / 49 cfm
Ultimate Vacuum: 3 x 10-2 mbar
Motor Power: 2.2 kW
Inlet Flange: ISO 63
Outlet Flange: NW 40
Weight: 557 lbs

Click Here for Edwards iL 70 Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.