Alcatel Drytel 100 Dry Vacuum Pumping Station
Item#: PN00292 Mfr Part#: Drytel 100 Manufacturer: Adixen / Alcatel
Condition: Remanufactured Call us for Availability
Remanufactured Alcatel Drytel 100 Dry Vacuum Pumping Station Drytel 100 is an oil-free turbo drag high vacuum pumping system, with delayed turbo pump start

Features:
  • Fully Remanufactured Turbo System
  • Ultimate Pressure: 3.75x10-6 Torr
  • Pumping speed 100 m3h

Price upon request
Item#: PN00292 Mfr Part#: Drytel 100
Alcatel Drytel 100 Dry Vacuum Pumping Station
Item#: PN00292 Mfr Part#: Drytel 100 Manufacturer: Adixen / Alcatel

Alcatel Drytel 100 is an oil-free turbo drag high vacuum pumping system, with delayed turbo pump start. The Drytel 100 is a compact bench top, light weight and very quiet system that can operate from atmosphere to 5x10-6 Mbar. Simple one button operation.

 Alcatel Drytel 100 high vacuum pumping system is composed of a turbo drag pump backed with diaphragm pump. The Alcatel MDP5030 CP turbo drag pump is the primary high vacuum pump with DN-100-ISO inlet flange, Alcatel Drytel 100 system produce outstanding high vacuum flow rates. The Alcatel Drytel 30 comes standard with a solid-state frequency converter, electronic controls and an automatic valve to vent diaphragm pump to atmosphere.
 
Alcatel Drytel 100 oil-free turbo drag high vacuum pumping system is fully air cooled with an internal cooling fan, no additional cooling is required. Drytel 100 is designed for use with high vacuum chambers as a bench top unit. They are ideal for dry high vacuum applications & high vacuum instruments.
 
Alcatel Drytel100 usual applications: university research, space research, physics research laboratories, semiconductor process, analytical instruments, analytical laboratories, pharmaceutical research, chemical research, development laboratories, solar indusry, space simulation, mass spectrometry, leak detection, surface analysis, ion pump evacuation, vacuum gauge calibration, helium leak testing, along with many other high vacuum application.
 
 
 
If you are not sure if this system will meet your application requirements, please contact one of our Technical Specialist to discuss all technical questions.
 
Our knowledgeable staff will be happy to assist you. 
 

A&J Vacuum also repair / rebuild and service all Alcatel Vacuum and Turbo Pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page.

 
 
This item is non-returnable/non-refundable

Ultimate Pressure: 3.75x10-6

Pumping speed: 100 m3h

Input Power: 115 VAC 60 Hz

 

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Alcatel Drytel 100 Dry Vacuum Pumping Station
Item#: PN00292 Mfr Part#: Drytel 100 Manufacturer: Adixen / Alcatel

Alcatel Drytel 100 is an oil-free turbo drag high vacuum pumping system, with delayed turbo pump start. The Drytel 100 is a compact bench top, light weight and very quiet system that can operate from atmosphere to 5x10-6 Mbar. Simple one button operation.

 Alcatel Drytel 100 high vacuum pumping system is composed of a turbo drag pump backed with diaphragm pump. The Alcatel MDP5030 CP turbo drag pump is the primary high vacuum pump with DN-100-ISO inlet flange, Alcatel Drytel 100 system produce outstanding high vacuum flow rates. The Alcatel Drytel 30 comes standard with a solid-state frequency converter, electronic controls and an automatic valve to vent diaphragm pump to atmosphere.
 
Alcatel Drytel 100 oil-free turbo drag high vacuum pumping system is fully air cooled with an internal cooling fan, no additional cooling is required. Drytel 100 is designed for use with high vacuum chambers as a bench top unit. They are ideal for dry high vacuum applications & high vacuum instruments.
 
Alcatel Drytel100 usual applications: university research, space research, physics research laboratories, semiconductor process, analytical instruments, analytical laboratories, pharmaceutical research, chemical research, development laboratories, solar indusry, space simulation, mass spectrometry, leak detection, surface analysis, ion pump evacuation, vacuum gauge calibration, helium leak testing, along with many other high vacuum application.
 
 
 
If you are not sure if this system will meet your application requirements, please contact one of our Technical Specialist to discuss all technical questions.
 
Our knowledgeable staff will be happy to assist you. 
 

A&J Vacuum also repair / rebuild and service all Alcatel Vacuum and Turbo Pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page.

 
 

Ultimate Pressure: 3.75x10-6

Pumping speed: 100 m3h

Input Power: 115 VAC 60 Hz

 

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.