Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720
Item#: PN00328 Mfr Part#: 85720 Manufacturer: Leybold
Condition: Remanufactured In Stock
Remanufactured Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720

Features:
  • Fully Remanufactured
  • Oerlikon / Leybold
  • P/N 85720
  • Mains voltage, with selector switch: 100/120/220/240 V,%/-15%

PRICE: $2,700.00
WEB SAVINGS: $701.00
YOU PAY: $1,999.00
Item#: PN00328 Mfr Part#: 85720
Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720
Item#: PN00328 Mfr Part#: 85720 Manufacturer: Leybold

Fully Remanufactured Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720

 

Leybold Oerlikon NT20 Overview:


The mains voltage of Leybold Turbotronik NT20 is 100/120/220/240 V,%/-15%. Mains frequency of Leybold NT-20 is 50/60 Hz. Interface for data output of Turbotornik NT20 is RS 232/V.24. The weight of Oerlikon NT20 is 7 kg.

The electronic frequency converter TURBOTRONIK NT-20 is used to drive the following turbo molecular pumps:

  • TURBOVAC 150, 360,
  • TURBOVAC 150 CSV, 360 CSV,
  • TURBOVAC 150 V, 360 V,
  • TURBOVAC 151, 151 C, 361, 361 C,
  • TURBOVAC 600, 600 C,
  • TURBOVAC 1000, 1000 C, 1100 C.

These pumps each comprise a three-phase asynchronous motor with the appropriate rating to drive the rotor.

The TURBOTRONIK NT20 converts the single-phase mains voltage into a three-phase AC voltage with regulated frequency and amplitude.

Each installed TURBOVAC has been individually coded. The respective pump code must be entered using the DIP switches provided. For safety reasons, the TURBOVAC will not start up unless the two codes match.

The acceleration sequence, the regulation during operation, and the output speed will vary depending on the installed pump model.

The TURBOTRONIK NT 20 does not support the pump models TURBOVAC 150 H and TURBOVAC 360 H. LEYBOLD customer service can adjust the speed of each TURBOVAC to ± 5%, if required.


THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

 

Leybold NT 20 Rear Panel:


Leybold NT 20 Rear Panel, NT20, NT-20, 85720

 

Leybold NT 20 Dimensions:


Leybold NT 20 Dimensions, NT20, NT-20, 85720


Click Here for Leybold TURBOTRONIK NT 20 Manual


A&J Vacuum Services offers full repair/service of Leybold Turbotronik NT20 Controller, along with all other brands offered on our website. AJVS also services Leybold Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Fully Remanufactured Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720

 

Leybold NT 20 Technical Data:


Leybold NT 20 Technical Data, NT20, NT-20, 85720


Click Here for Leybold TURBOTRONIK NT 20 Manual


A&J Vacuum Services offers full repair/service of Leybold Turbotronik NT20 Controller, along with all other brands offered on our website. AJVS also services Leybold Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720
Item#: PN00328 Mfr Part#: 85720 Manufacturer: Leybold

Fully Remanufactured Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720

 

Leybold Oerlikon NT20 Overview:


The mains voltage of Leybold Turbotronik NT20 is 100/120/220/240 V,%/-15%. Mains frequency of Leybold NT-20 is 50/60 Hz. Interface for data output of Turbotornik NT20 is RS 232/V.24. The weight of Oerlikon NT20 is 7 kg.

The electronic frequency converter TURBOTRONIK NT-20 is used to drive the following turbo molecular pumps:

  • TURBOVAC 150, 360,
  • TURBOVAC 150 CSV, 360 CSV,
  • TURBOVAC 150 V, 360 V,
  • TURBOVAC 151, 151 C, 361, 361 C,
  • TURBOVAC 600, 600 C,
  • TURBOVAC 1000, 1000 C, 1100 C.

These pumps each comprise a three-phase asynchronous motor with the appropriate rating to drive the rotor.

The TURBOTRONIK NT20 converts the single-phase mains voltage into a three-phase AC voltage with regulated frequency and amplitude.

Each installed TURBOVAC has been individually coded. The respective pump code must be entered using the DIP switches provided. For safety reasons, the TURBOVAC will not start up unless the two codes match.

The acceleration sequence, the regulation during operation, and the output speed will vary depending on the installed pump model.

The TURBOTRONIK NT 20 does not support the pump models TURBOVAC 150 H and TURBOVAC 360 H. LEYBOLD customer service can adjust the speed of each TURBOVAC to ± 5%, if required.


THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

 

Leybold NT 20 Rear Panel:


Leybold NT 20 Rear Panel, NT20, NT-20, 85720

 

Leybold NT 20 Dimensions:


Leybold NT 20 Dimensions, NT20, NT-20, 85720


Click Here for Leybold TURBOTRONIK NT 20 Manual


A&J Vacuum Services offers full repair/service of Leybold Turbotronik NT20 Controller, along with all other brands offered on our website. AJVS also services Leybold Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Fully Remanufactured Oerlikon Leybold Turbotronik NT 20 Turbo Pump Controller, 85720

 

Leybold NT 20 Technical Data:


Leybold NT 20 Technical Data, NT20, NT-20, 85720


Click Here for Leybold TURBOTRONIK NT 20 Manual


A&J Vacuum Services offers full repair/service of Leybold Turbotronik NT20 Controller, along with all other brands offered on our website. AJVS also services Leybold Turbo Pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.