Pfeiffer Vacuum TCP 015 Turbo Pump Controller, PMC01598
Item#: PN00342 Mfr Part#: PMC01598 Manufacturer: Pfeiffer Vacuum
Condition: Remanufactured In Stock
Remanufactured Pfeiffer Vacuum TCP 015 (TCP015) Turbo Pump Controller PM C01 598

Features:

PRICE: $1,975.00
WEB SAVINGS: $625.00
YOU PAY: $1,350.00
Item#: PN00342 Mfr Part#: PMC01598
Pfeiffer Vacuum TCP 015 Turbo Pump Controller, PMC01598
Item#: PN00342 Mfr Part#: PMC01598 Manufacturer: Pfeiffer Vacuum

Fully Remanufactured Pfeiffer TCP 015 Turbo Pump Controller, PMC01598

The Electronic Drive Unit TCP 015 (TCP015) serves to drive PFEIFFER turbomolecular pumps with single phase direct current motors (1500 Hz). With the aid of a transformer the mains voltage is reduced to 32 V, rectified and provides the drive energy for the Print Module TCP 035 which is an element of the TCP 015. The switchable transformer power pack covers the following input voltage ranges:

  • 90-112 V
  • 108-133 V
  • 198-245 V
  • 216-267 V AC.

The TCP can be operated in conjunction with Pumping Station Control Unit TCS 015 to operate a pumping station with backing pump. The delivery consignment encompasses:

  • Electronic Drive Unit TCP 015
  • Mating plug for X1, X2, X3.

The TCP 015 has been suppressed in accordance with German Industrial Standard VDE 0871, limit value curve B. The unit has been tested and cleared by the appropriate authorities in accordance with EN 61010/VDE0411 “Safety Ordinance For Electrical Units”. The electronic drive unit contains the following functional features:

  • Switching power pack
  • Motor drive
  • Monitoring and process control
  • Illuminating diode display with information concerning the operational status of the pump
  • Serial Interface RS 232/ RS 485 on the Print Module of the TCP 035

Compatible with Turbo Pumps TMH /TMU 062 to TMH /TMU 064, TMH /TMU 065.

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

 

Fully Remanufactured Pfeiffer TCP 015 Turbo Pump Controller, PMC01598

Technical Data

Electronic Drive Unit TCP 015    
     
Connection voltage   (100 V) 90 - 112
switchable V AC (120 V) 108 - 133
  V AC (220 V) 198 - 245
    (240 V) 216 - 267
Mains frequency Hz 50/60
Power take-up, max. VA 110
With air cooling    
Output voltage, max. V 30 - 40 V
Normal operations    
Start-up current A 2,2
Nominal frequency ± 2% max. Hz 1500
Stand-by operations    
Start-up current A 2,2
Nominal frequency ± 2% max. Hz 1000
Contact load K1    
Ohmic load A 4
Inductive load A 2
Switching voltage, max. VAC 265
VDC 30  
Analog outputs:    
Rotation speed 10 V = 1500 Hz  
  ± 2%  
Current 10 V = 2,5 A  
  ± 5%  
BLoad carrying capacity of mA 5
the 0-10 V outputs    
Start-up time min 8 - 60
Works setting min 8
Rotation speed switchpoint Hz 750
Permissible ambient temperature °C 0 - 40
Cable length Pump - TCP m 3
Dimensions, front panel mm 128,5x106,3
Insertion length mm 227
Weight kg 2,7
Pfeiffer Vacuum TCP 015 (TCP 015) Turbo Pump Controller, PMC01598
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Vacuum TCP 015 Turbo Pump Controller, PMC01598
Item#: PN00342 Mfr Part#: PMC01598 Manufacturer: Pfeiffer Vacuum

Fully Remanufactured Pfeiffer TCP 015 Turbo Pump Controller, PMC01598

The Electronic Drive Unit TCP 015 (TCP015) serves to drive PFEIFFER turbomolecular pumps with single phase direct current motors (1500 Hz). With the aid of a transformer the mains voltage is reduced to 32 V, rectified and provides the drive energy for the Print Module TCP 035 which is an element of the TCP 015. The switchable transformer power pack covers the following input voltage ranges:

  • 90-112 V
  • 108-133 V
  • 198-245 V
  • 216-267 V AC.

The TCP can be operated in conjunction with Pumping Station Control Unit TCS 015 to operate a pumping station with backing pump. The delivery consignment encompasses:

  • Electronic Drive Unit TCP 015
  • Mating plug for X1, X2, X3.

The TCP 015 has been suppressed in accordance with German Industrial Standard VDE 0871, limit value curve B. The unit has been tested and cleared by the appropriate authorities in accordance with EN 61010/VDE0411 “Safety Ordinance For Electrical Units”. The electronic drive unit contains the following functional features:

  • Switching power pack
  • Motor drive
  • Monitoring and process control
  • Illuminating diode display with information concerning the operational status of the pump
  • Serial Interface RS 232/ RS 485 on the Print Module of the TCP 035

Compatible with Turbo Pumps TMH /TMU 062 to TMH /TMU 064, TMH /TMU 065.

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

 

Fully Remanufactured Pfeiffer TCP 015 Turbo Pump Controller, PMC01598

Technical Data

Electronic Drive Unit TCP 015    
     
Connection voltage   (100 V) 90 - 112
switchable V AC (120 V) 108 - 133
  V AC (220 V) 198 - 245
    (240 V) 216 - 267
Mains frequency Hz 50/60
Power take-up, max. VA 110
With air cooling    
Output voltage, max. V 30 - 40 V
Normal operations    
Start-up current A 2,2
Nominal frequency ± 2% max. Hz 1500
Stand-by operations    
Start-up current A 2,2
Nominal frequency ± 2% max. Hz 1000
Contact load K1    
Ohmic load A 4
Inductive load A 2
Switching voltage, max. VAC 265
VDC 30  
Analog outputs:    
Rotation speed 10 V = 1500 Hz  
  ± 2%  
Current 10 V = 2,5 A  
  ± 5%  
BLoad carrying capacity of mA 5
the 0-10 V outputs    
Start-up time min 8 - 60
Works setting min 8
Rotation speed switchpoint Hz 750
Permissible ambient temperature °C 0 - 40
Cable length Pump - TCP m 3
Dimensions, front panel mm 128,5x106,3
Insertion length mm 227
Weight kg 2,7
Pfeiffer Vacuum TCP 015 (TCP 015) Turbo Pump Controller, PMC01598
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.