Edwards EXT75DX Compound Turbo Pump, DN 40 NW, B722-43-000, B72243000
Item#: PN00362 Mfr Part#: B72243000 / B722-43-000 Manufacturer: Edwards Vacuum
Condition: Remanufactured In Stock
Remanufactured Edwards EXT 75 DX Compound Turbo Vacuum Pump, DN 40 NW, B72243000

Features:
  • Inlet flange: DN 40 KF
  • Pumping speed (N2): 42 ls-1
  • Compression ratio (N2): > 1 x 1011
  • Vent port: 1/8" BSP

PRICE: $5,900.00
WEB SAVINGS: $405.00
YOU PAY: $5,495.00
Item#: PN00362 Mfr Part#: B72243000 / B722-43-000
Edwards EXT75DX Compound Turbo Pump, DN 40 NW, B722-43-000, B72243000
Item#: PN00362 Mfr Part#: B72243000 / B722-43-000 Manufacturer: Edwards Vacuum

Edwards EXT 75 DX Compound Turbo Vacuum Pump, DN 40 NW, B72243000

 

This Pump Has Become Obsolete - Please Call For Availability.

 

Edwards EXT 75 DX Overview


The Edwards EXT75DX / B72243000 is a hybrid bearing compound turbo pump that combines the proven technology of a ceramic mechanical lower bearing, a dry permanent magnetic upper bearing and Holweck drag stage with the added convenience of an on-board 24V controller allowing parallel and serial communication compatible with Edwards TAG and TIC controllers.

Edwards EXT 75DX It is available with either a DN 40 NW, ISO 63, DN 63 CF or an ISO 100 inlet flange with an N2 pumping speed of up to 66 ls-1. A basic pump system would require an EXT75DX pump, a TAG or TIC controller, either an air or water cooling accessory and a suitable backing pump.

 

Edwards EXT 75 DX Features


  • Compatible with TIC turbo instrument controller
  • Multiple communication modes available including parallel mode, which allows traditional control signal interface and serial mode, which allows RS232 interface
  • Numerous user configurable parameters via RS232 interface including vent valve control settings, normal speed indication, stand-by running speed, programmable power settings, power consumption and pump temperature
  • Enhanced monitoring capabiltiy including pump speed, power and temperature

 

Edwards EXT 75 DX Dimensions


Edwards EXT75DX Compound Turbo Pump, DN 100 ISO, B722-46-000, B72246000, EXT-75DX, EXT 75DX


Click Here for Edwards EXT 75 DX Manual


A&J Vacuum also Repair / Rebuild and Rervice all Edwards EXT and nEXT Turbo Pumps Edwards Vacuum Gauges with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Edwards EXT 75 DX Compound Turbo Vacuum Pump, DN 40 NW, B72243000

 

Edwards EXT 75 DX Technical Data


Edwards EXT75DX Compound Turbo Pump, DN 100 ISO, B722-46-000, B72246000, EXT-75DX, EXT 75DX


Click Here for Edwards EXT 75 DX Manual


A&J Vacuum also Repair / Rebuild and Rervice all Edwards EXT and nEXT Turbo Pumps Edwards Vacuum Gauges with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards EXT75DX Compound Turbo Pump, DN 40 NW, B722-43-000, B72243000
Item#: PN00362 Mfr Part#: B72243000 / B722-43-000 Manufacturer: Edwards Vacuum

Edwards EXT 75 DX Compound Turbo Vacuum Pump, DN 40 NW, B72243000

 

This Pump Has Become Obsolete - Please Call For Availability.

 

Edwards EXT 75 DX Overview


The Edwards EXT75DX / B72243000 is a hybrid bearing compound turbo pump that combines the proven technology of a ceramic mechanical lower bearing, a dry permanent magnetic upper bearing and Holweck drag stage with the added convenience of an on-board 24V controller allowing parallel and serial communication compatible with Edwards TAG and TIC controllers.

Edwards EXT 75DX It is available with either a DN 40 NW, ISO 63, DN 63 CF or an ISO 100 inlet flange with an N2 pumping speed of up to 66 ls-1. A basic pump system would require an EXT75DX pump, a TAG or TIC controller, either an air or water cooling accessory and a suitable backing pump.

 

Edwards EXT 75 DX Features


  • Compatible with TIC turbo instrument controller
  • Multiple communication modes available including parallel mode, which allows traditional control signal interface and serial mode, which allows RS232 interface
  • Numerous user configurable parameters via RS232 interface including vent valve control settings, normal speed indication, stand-by running speed, programmable power settings, power consumption and pump temperature
  • Enhanced monitoring capabiltiy including pump speed, power and temperature

 

Edwards EXT 75 DX Dimensions


Edwards EXT75DX Compound Turbo Pump, DN 100 ISO, B722-46-000, B72246000, EXT-75DX, EXT 75DX


Click Here for Edwards EXT 75 DX Manual


A&J Vacuum also Repair / Rebuild and Rervice all Edwards EXT and nEXT Turbo Pumps Edwards Vacuum Gauges with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Edwards EXT 75 DX Compound Turbo Vacuum Pump, DN 40 NW, B72243000

 

Edwards EXT 75 DX Technical Data


Edwards EXT75DX Compound Turbo Pump, DN 100 ISO, B722-46-000, B72246000, EXT-75DX, EXT 75DX


Click Here for Edwards EXT 75 DX Manual


A&J Vacuum also Repair / Rebuild and Rervice all Edwards EXT and nEXT Turbo Pumps Edwards Vacuum Gauges with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.