Item#: PN06199 Mfr Part#: PM C01 821-A / PMC01821A Manufacturer: Pfeiffer Vacuum
Condition: New In Stock
New Pfeiffer Vacuum DCU 180 Display Control Unit with integrated power supply, PMC01821 , DCU180 Controller, PM C01 821

Features:
  • For power supply, control and operation of appropriate Pfeiffer Vacuum products
  • Ideally matched to HiPace 300 with TC 110
  • Connection of Pfeiffer Vacuum ActiveLine gauges possible
  • With integrated power supply

PRICE: $2,519.00
WEB SAVINGS: $229.00
YOU PAY: $2,290.00
Item#: PN06199 Mfr Part#: PM C01 821-A / PMC01821A
Pfeiffer DCU 180 Display Control Including Power Supply, PM C01 821-A / PMC01821A, DCU180
Item#: PN06199 Mfr Part#: PM C01 821-A / PMC01821A Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum DCU 180 Display Control Unit with integrated power supply, PMC01821A , DCU180 Controller, PM C01 821

 

New Pfeiffer DCU180 Turbo Coontroller PMC01821 Features;

  • To control and monitor all parameters of the drive electronics
  • Comes with With integrated power supply
  • deally matched to HiPace 300 with TC 110

 

The DCU 180 / PM C011 821 is a display and control unit for Pfeiffer Vacuum vacuum pumps with integrated electronic drive unit.

This DCU 180 displays all control parameters for the electronic drive unit. It is also possible to connect a pressure measuring vacuum gauge directlyy to the back of the DCU 180.

HiPace stands for a complete line of compact yet powerful turbopumps featuring pumping speeds that range from 10 – 800 liters per second. It offers a cost-effective yet flexible installation in any orientation. The proven bearing system affords unrivaled dependability. The improved rotor design makes for higher pumping speeds, higher backing pump compatibility and higher gas throughputs coupled with very good compression for light gases. The new, integrated drive electronics reduce the need for cumbersome and costly cabling.

 

A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps  along with all other  Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

 

Pfeiffer Vacuum DCU 180 Display Control Unit with integrated power supply, PMC01821 , DCU180 Controller

 

New Pfeiffer DCU 180 / PM C01 821 Technical data:

Ambient temperature 5-50 °C
Mains requirement: frequency (range) 50/60 Hz
Mains requirement: power consumption 210 VA
Mains requirement: voltage (range) 115-230 (-20 - +15 %) V AC
OuTPU t current 7.5 A
OuTPU t voltage 24 (± 2 %) V DC
Protection category IP 20
Weight 1.7 kg

 

A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps  along with all other  Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

 

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer DCU 180 Display Control Including Power Supply, PM C01 821-A / PMC01821A, DCU180
Item#: PN06199 Mfr Part#: PM C01 821-A / PMC01821A Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum DCU 180 Display Control Unit with integrated power supply, PMC01821A , DCU180 Controller, PM C01 821

 

New Pfeiffer DCU180 Turbo Coontroller PMC01821 Features;

  • To control and monitor all parameters of the drive electronics
  • Comes with With integrated power supply
  • deally matched to HiPace 300 with TC 110

 

The DCU 180 / PM C011 821 is a display and control unit for Pfeiffer Vacuum vacuum pumps with integrated electronic drive unit.

This DCU 180 displays all control parameters for the electronic drive unit. It is also possible to connect a pressure measuring vacuum gauge directlyy to the back of the DCU 180.

HiPace stands for a complete line of compact yet powerful turbopumps featuring pumping speeds that range from 10 – 800 liters per second. It offers a cost-effective yet flexible installation in any orientation. The proven bearing system affords unrivaled dependability. The improved rotor design makes for higher pumping speeds, higher backing pump compatibility and higher gas throughputs coupled with very good compression for light gases. The new, integrated drive electronics reduce the need for cumbersome and costly cabling.

 

A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps  along with all other  Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

 

Pfeiffer Vacuum DCU 180 Display Control Unit with integrated power supply, PMC01821 , DCU180 Controller

 

New Pfeiffer DCU 180 / PM C01 821 Technical data:

Ambient temperature 5-50 °C
Mains requirement: frequency (range) 50/60 Hz
Mains requirement: power consumption 210 VA
Mains requirement: voltage (range) 115-230 (-20 - +15 %) V AC
OuTPU t current 7.5 A
OuTPU t voltage 24 (± 2 %) V DC
Protection category IP 20
Weight 1.7 kg

 

A&J Vacuum Repair / Rebuild and Service all Pfeiffer Vacuum DCU 180 / PM C01 821-A Turbo Pumps  along with all other  Pfeiffer Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

 

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.