Edwards EXT 70H Turbo Pump, DN 100 ISO, 24 V, B72226991, EXT70
Item#: PN07013 Mfr Part#: B72226991 Manufacturer: Edwards Vacuum
Condition: Remanufactured Call us for Availability
Remanufactured Edwards EXT70H Turbo Pump with DN-100 ISO Inlet Flange, KF16 Outlet Flange, 24 V, B72226991, EXT-70

Features:
  • Inlet flange: DN 100 ISO
  • Outlet flange: KF 16
  • 24 V

Price upon request
Item#: PN07013 Mfr Part#: B72226991
Edwards EXT 70H Turbo Pump, DN 100 ISO, 24 V, B72226991, EXT70
Item#: PN07013 Mfr Part#: B72226991 Manufacturer: Edwards Vacuum

Edwards EXT 70H Turbo Pump with DN-100 ISO Inlet Flange, KF16 Outlet Flange, 24 V, B72226991, EXT-70, EXT70H, B722-26-991

 

General Overview:

The Edwards EXT 70H, EXT70Hi, EXT250H and EXT250Hi pumps are compound vacuum pumps that combine a turbomolecular pump and a drag pump on a single shaft.

This Edwards EXT70H / B72226991 turbomolecular pump is made from a multi-stage axial-flow turbine which is optimised for operation in molecular flow conditions. The drag pump is made from pumping channels formed by plane rotating disks. The drag pump is designed for operation at higher pressures than conventional turbomolecular pumps.

The light alloy rotor is machined from one piece to form the angled blades of the turbomolecular pump and the disks of the drag pump. The rotor blades rotate between angled stator blades which are supported by spacer rings.

The Edwards Rotor and Stator blades have an open structure at the pump inlet, and a more closed structure at the outlet. This configuration gives an optimum combination of pumping speed and compression when pumping gases of both high and low molecular weight. For the blades to be effective, their speed must be close to the thermal velocity of the gas.

The Rotor of the EXT70H therefore rotates at up to 90000 r min-1, and the rotor of the EXT250H/Hi therefore rotates at up to 60000 r min-1.

Process Gas from the inlet is compressed through each of the bladed stages of the turbomolecular pump and transferred to the drag pump. In the drag pump stages, the gas is further compressed as it is pumped around the channels formed by the separation of the disks. The inlet and outlet of each channel is separated by a close-running seal which diverts the gas through a port to the next channel, or to the pump outlet.

 

EXT 70H DN100ISO-K Technical Data:

  • Inlet Flange, DN100 ISO-K (No Groove)
  • Outlet FLange DN25 KF-F
  • Ultimate Pressure 5 x 10-9 mbar
  • Puming Speed  for N2 65 l/sec
  • Minimum backing pump requirement 0.6 m3h
  • Recomended backing pump  Edwards E2M0.7
  • Nominal Rotational Speed: 90000 r min
It is recommend that wherever possible, you cool the pump by forced-air or water-cooling. You must use water - cooling in any of the following operating conditions:
  • Backing pressure > 10 mbar (1000 Pa) and interstage flow 20sccm (0.3mbar l s-1, 30 Pa l s-1)
  • Backing pressure > 8 mbar (800 Pa) and interstage flow 30sccm (0.5mbar l s-1, 50 Pa l s-1)

Please refer to EXT70 Operating Instructions for more details

The EXT 70H rotating assembly is supported at the inlet end by a frictionless magnetic bearing and by a precision ceramic ball bearing at the outlet end. The ball bearing is lubricated from an oil reservoir and wick mechanism.

It is recomended to use inlet-screen and inlet-strainer protect the pump against damage which would be caused by debris which enters the pump. The inlet-screen also protects you from the sharp blades in the pump.

The EXT pump has a vent-port that you can use to vent the pump and your vacuum system to atmospheric pressure. The vent-port introduces vent gas part way up the pump rotor; this ensures maximum cleanliness. The pump is supplied with a manual vent-valve fitted to the vent-port.

Edwards EXT pump can fited with optional vent-port adaptor and purge restrictor to the purge-port to control the flow rate of the purge gas and to filter the gas supply.


 

A&J Vacuum also repair / rebuild and service all Edwards EXT 70H / B72226991 with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

This item is non-returnable/non-refundable

Edwards EXT 70H Turbo Pump with DN-100 ISO Inlet Flange, KF16 Outlet Flange, 24 V, B72226991, EXT-70, EXT70H, B722-26-991

 

EXT 70H DN100ISO-K Technical Data:

  • Inlet Flange, DN100 ISO-K (No Groove)
  • Outlet FLange DN25 KF-F
  • Ultimate Pressure 5 x 10-9 mbar
  • Puming Speed  for N2 65 l/sec
  • Minimum backing pump requirement 0.6 m3h
  • Recomended backing pump  Edwards E2M0.7
  • Nominal Rotational Speed: 90000 r min
It is recommend that wherever possible, you cool the pump by forced-air or water-cooling. You must use water - cooling in any of the following operating conditions:
  • Backing pressure > 10 mbar (1000 Pa) and interstage flow 20sccm (0.3mbar l s-1, 30 Pa l s-1)
  • Backing pressure > 8 mbar (800 Pa) and interstage flow 30sccm (0.5mbar l s-1, 50 Pa l s-1)

Please refer to EXT70 Operating Instructions for more details


 

A&J Vacuum also repair / rebuild and service all Edwards EXT 70H / B72226991 with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards EXT 70H Turbo Pump, DN 100 ISO, 24 V, B72226991, EXT70
Item#: PN07013 Mfr Part#: B72226991 Manufacturer: Edwards Vacuum

Edwards EXT 70H Turbo Pump with DN-100 ISO Inlet Flange, KF16 Outlet Flange, 24 V, B72226991, EXT-70, EXT70H, B722-26-991

 

General Overview:

The Edwards EXT 70H, EXT70Hi, EXT250H and EXT250Hi pumps are compound vacuum pumps that combine a turbomolecular pump and a drag pump on a single shaft.

This Edwards EXT70H / B72226991 turbomolecular pump is made from a multi-stage axial-flow turbine which is optimised for operation in molecular flow conditions. The drag pump is made from pumping channels formed by plane rotating disks. The drag pump is designed for operation at higher pressures than conventional turbomolecular pumps.

The light alloy rotor is machined from one piece to form the angled blades of the turbomolecular pump and the disks of the drag pump. The rotor blades rotate between angled stator blades which are supported by spacer rings.

The Edwards Rotor and Stator blades have an open structure at the pump inlet, and a more closed structure at the outlet. This configuration gives an optimum combination of pumping speed and compression when pumping gases of both high and low molecular weight. For the blades to be effective, their speed must be close to the thermal velocity of the gas.

The Rotor of the EXT70H therefore rotates at up to 90000 r min-1, and the rotor of the EXT250H/Hi therefore rotates at up to 60000 r min-1.

Process Gas from the inlet is compressed through each of the bladed stages of the turbomolecular pump and transferred to the drag pump. In the drag pump stages, the gas is further compressed as it is pumped around the channels formed by the separation of the disks. The inlet and outlet of each channel is separated by a close-running seal which diverts the gas through a port to the next channel, or to the pump outlet.

 

EXT 70H DN100ISO-K Technical Data:

  • Inlet Flange, DN100 ISO-K (No Groove)
  • Outlet FLange DN25 KF-F
  • Ultimate Pressure 5 x 10-9 mbar
  • Puming Speed  for N2 65 l/sec
  • Minimum backing pump requirement 0.6 m3h
  • Recomended backing pump  Edwards E2M0.7
  • Nominal Rotational Speed: 90000 r min
It is recommend that wherever possible, you cool the pump by forced-air or water-cooling. You must use water - cooling in any of the following operating conditions:
  • Backing pressure > 10 mbar (1000 Pa) and interstage flow 20sccm (0.3mbar l s-1, 30 Pa l s-1)
  • Backing pressure > 8 mbar (800 Pa) and interstage flow 30sccm (0.5mbar l s-1, 50 Pa l s-1)

Please refer to EXT70 Operating Instructions for more details

The EXT 70H rotating assembly is supported at the inlet end by a frictionless magnetic bearing and by a precision ceramic ball bearing at the outlet end. The ball bearing is lubricated from an oil reservoir and wick mechanism.

It is recomended to use inlet-screen and inlet-strainer protect the pump against damage which would be caused by debris which enters the pump. The inlet-screen also protects you from the sharp blades in the pump.

The EXT pump has a vent-port that you can use to vent the pump and your vacuum system to atmospheric pressure. The vent-port introduces vent gas part way up the pump rotor; this ensures maximum cleanliness. The pump is supplied with a manual vent-valve fitted to the vent-port.

Edwards EXT pump can fited with optional vent-port adaptor and purge restrictor to the purge-port to control the flow rate of the purge gas and to filter the gas supply.


 

A&J Vacuum also repair / rebuild and service all Edwards EXT 70H / B72226991 with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Edwards EXT 70H Turbo Pump with DN-100 ISO Inlet Flange, KF16 Outlet Flange, 24 V, B72226991, EXT-70, EXT70H, B722-26-991

 

EXT 70H DN100ISO-K Technical Data:

  • Inlet Flange, DN100 ISO-K (No Groove)
  • Outlet FLange DN25 KF-F
  • Ultimate Pressure 5 x 10-9 mbar
  • Puming Speed  for N2 65 l/sec
  • Minimum backing pump requirement 0.6 m3h
  • Recomended backing pump  Edwards E2M0.7
  • Nominal Rotational Speed: 90000 r min
It is recommend that wherever possible, you cool the pump by forced-air or water-cooling. You must use water - cooling in any of the following operating conditions:
  • Backing pressure > 10 mbar (1000 Pa) and interstage flow 20sccm (0.3mbar l s-1, 30 Pa l s-1)
  • Backing pressure > 8 mbar (800 Pa) and interstage flow 30sccm (0.5mbar l s-1, 50 Pa l s-1)

Please refer to EXT70 Operating Instructions for more details


 

A&J Vacuum also repair / rebuild and service all Edwards EXT 70H / B72226991 with Edwards Scroll Vacuum Pumps Edwards Turbo Pump repair, Edwards Vane Pumps and all other Edwards Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.