phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Edwards Active Pirani Vacuum Gauge, APG M 16 AL, D02171000
Item#: PN07419 Mfr Part#: D02171000 Manufacturer: Edwards Vacuum
Condition: Discontinued
Discontinued Edwards Active Pirani Vacuum Gauge, APG M 16 AL (APGM16AL), D02171000

Features:
  • Pressure Range: Atmosphere to 10-3 mbar
  • Maximum Over Pressure: 6 bar absolute
  • Power Supply: 20 to 36 V dc (max 1 V ripple)
  • Power Consumption: 1.5 W max

This product has been discontinued and is no longer available for sale
Item#: PN07419 Mfr Part#: D02171000
Edwards Active Pirani Vacuum Gauge, APG M 16 AL, D02171000
Item#: PN07419 Mfr Part#: D02171000 Manufacturer: Edwards Vacuum

Edwards Active Pirani Vacuum Gauge, APG M 16 AL (APGM16AL), D02171000

 

Edwards APG M 16 AL Overview:


The Edwards APG, is a Pirani vacuum gauge and gauge controller in a single compact unit. The measurement range of the APG-M and of the corrosion-resistant APG-MP is 100 to 1 x 10-3 mbar: the range of the APG-L is 10 to 1 x 10-4 mbar. All of the gauges will indicate pressures up to 1000 mbar at reduced accuracy. The APG requires a 20 to 36 V d.c. power supply: it has a 2 to 10 V d.c. analogue output which is related to pressure. The APG is compatible with all of the Edwards AGC’s (Active Gauge Controllers) and with the appropriate versions of the Edwards AGD’s (Active Gauge Displays). Alternatively, you can use an independent power supply for the APG and you can read the APG output signal with a voltmeter or an analogue- to-digital converter.

An 8-way electrical connector socket on the APG is used to connect the APG to your AGC, AGD or electrical supply and voltmeter. Electrical cables fitted with suitable connector plugs are available as accessories. A gauge identification signal is available on the electrical connector: this signal is used by Edwards AGC’s to identify which type of Active gauge is connected, that is one of the following types:

  • APG-M/MP
  • APG-L

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Edwards APG M 16 AL Dimensions:


Edwards APG L 16 AL, D0217300, Dimensions


Click Here for Edwards APG M 16 AL Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards Active Pirani Vacuum Gauge, APG M 16 AL (APGM16AL), D02171000

 

Edwards APG M 16 AL Technical Data:


Pressure Range: Atmosphere to 10-3 mbar
Maximum Over Pressure: 6 bar absolute
Power Supply: 20 to 36 V dc (max 1 V ripple)
Power Consumption: 1.5 W max
Output Signal: 2 to 10 V dc
Socket Connector: 8 way FCC68 compatible

Click Here for Edwards APG M 16 AL Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Edwards Active Pirani Vacuum Gauge, APG M 16 AL, D02171000
Item#: PN07419 Mfr Part#: D02171000 Manufacturer: Edwards Vacuum

Edwards Active Pirani Vacuum Gauge, APG M 16 AL (APGM16AL), D02171000

 

Edwards APG M 16 AL Overview:


The Edwards APG, is a Pirani vacuum gauge and gauge controller in a single compact unit. The measurement range of the APG-M and of the corrosion-resistant APG-MP is 100 to 1 x 10-3 mbar: the range of the APG-L is 10 to 1 x 10-4 mbar. All of the gauges will indicate pressures up to 1000 mbar at reduced accuracy. The APG requires a 20 to 36 V d.c. power supply: it has a 2 to 10 V d.c. analogue output which is related to pressure. The APG is compatible with all of the Edwards AGC’s (Active Gauge Controllers) and with the appropriate versions of the Edwards AGD’s (Active Gauge Displays). Alternatively, you can use an independent power supply for the APG and you can read the APG output signal with a voltmeter or an analogue- to-digital converter.

An 8-way electrical connector socket on the APG is used to connect the APG to your AGC, AGD or electrical supply and voltmeter. Electrical cables fitted with suitable connector plugs are available as accessories. A gauge identification signal is available on the electrical connector: this signal is used by Edwards AGC’s to identify which type of Active gauge is connected, that is one of the following types:

  • APG-M/MP
  • APG-L

 

*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*

 

Edwards APG M 16 AL Dimensions:


Edwards APG L 16 AL, D0217300, Dimensions


Click Here for Edwards APG M 16 AL Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

Edwards Active Pirani Vacuum Gauge, APG M 16 AL (APGM16AL), D02171000

 

Edwards APG M 16 AL Technical Data:


Pressure Range: Atmosphere to 10-3 mbar
Maximum Over Pressure: 6 bar absolute
Power Supply: 20 to 36 V dc (max 1 V ripple)
Power Consumption: 1.5 W max
Output Signal: 2 to 10 V dc
Socket Connector: 8 way FCC68 compatible

Click Here for Edwards APG M 16 AL Manual


A&J Vacuum Services offers full repair/service of Edwards Vacuum Pumps, along with all other brands offered on our website. AJVS also services Edwards turbo pumps and rotary vane pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.