The gauge consists of two separate measurement systems (Pirani and cold cathode system) the signals of which are combined in such a way that one measurement signal is output. The Pirani measurement circuit is always on.
Over the whole measuring range, the measuring signal is output as a logarithm of the pressure.
The gauge is factory-calibrated. If used under different climatic conditions, through extreme temperatures, aging or contamination, and after exchanging the sensor, the characteristic curve can be offset and readjustment may become necessary.
The cold cathode measuring circuit, which is dominant for low pressures (<1×10-3mbar), is factory-calibrated and cannot be adjusted. By way of contrast, the Pirani measuring circuit can be adjusted. Any adjustment has a negligible effect on the pressure range between approx. 10-2mbar and 102mbar.
*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*
Click Here for Agilent FRG 700 Manual
A&J Vacuum Services offers full repair/service of Agilent / Varian, along with all other brands offered on our website. AJVS also services Agilent / Varian pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Measurement range | 5 x 10-9 to 1000 mbar (3.8 x 10-9 to 760 Torr) | ||||||
Accuracy | ± 30 % of reading, typical | ||||||
Repeatability | ± 5 % of reading, typical | ||||||
Mounting orientation | Any | ||||||
Admissible temperature (ambient) | Operation Storage | Bake-out* | (Pirani) | Filament Temperature | |||
5 to 55 °C | –40 to +65 °C | 150 °C | 120 °C | ||||
Supply voltage | At gauge | Ripple | Power consumption | ||||
15 to 30 VDC | ≤1 Vpp | ≤2 W | |||||
Output signal (measurement signal) | Voltage range | Measurement range | |||||
0 to 10.5 V | 1.82 to 8.6 V | ||||||
Voltage vs. pressure | 0.6 V/decade, logarithmic | ||||||
Error signal | <0.5 V (no supply), >9.5 V (Pirani sensor, filament rupture) | ||||||
Minimum loaded impedance | 10 kΩ, short-circuit proof | ||||||
Response time | <10 ms (@ p> 10-6 mbar), ≈1000 ms (@ p= 10-8 mbar) | ||||||
Identification gauge | 85 kΩ, referenced to supply common | ||||||
Status | Pirani-only mode | Combined Pirani/cold cathode mode | LED | ||||
0 V (low) | 15 V to 30 (high) | LED green high voltage on | |||||
Electrical connection | FCC 68 appliance connector, 8 poles, female | ||||||
Sensor cable | 8 poles plus shielding | ||||||
Maximum cable length | ≤ 50 m | ||||||
Operating voltage/current | ≤3.3 kV/≤500 A | ||||||
Materials exposed to vacuum | SS, Al2O3, FPM75, Mo, Ni, Au, W | ||||||
Internal volume | ≈ 20 cm3 | ||||||
Weight | DN 25 ISO-KF ≈700g, DN 40 CF ≈980g | ||||||
Standards | EN 61000-6-2, EN 61000-6-3, EN 61010-1 |
Click Here for Agilent FRG 700 Manual
A&J Vacuum Services offers full repair/service of Agilent / Varian, along with all other brands offered on our website. AJVS also services Agilent / Varian pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
The gauge consists of two separate measurement systems (Pirani and cold cathode system) the signals of which are combined in such a way that one measurement signal is output. The Pirani measurement circuit is always on.
Over the whole measuring range, the measuring signal is output as a logarithm of the pressure.
The gauge is factory-calibrated. If used under different climatic conditions, through extreme temperatures, aging or contamination, and after exchanging the sensor, the characteristic curve can be offset and readjustment may become necessary.
The cold cathode measuring circuit, which is dominant for low pressures (<1×10-3mbar), is factory-calibrated and cannot be adjusted. By way of contrast, the Pirani measuring circuit can be adjusted. Any adjustment has a negligible effect on the pressure range between approx. 10-2mbar and 102mbar.
*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*
Click Here for Agilent FRG 700 Manual
A&J Vacuum Services offers full repair/service of Agilent / Varian, along with all other brands offered on our website. AJVS also services Agilent / Varian pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
Measurement range | 5 x 10-9 to 1000 mbar (3.8 x 10-9 to 760 Torr) | ||||||
Accuracy | ± 30 % of reading, typical | ||||||
Repeatability | ± 5 % of reading, typical | ||||||
Mounting orientation | Any | ||||||
Admissible temperature (ambient) | Operation Storage | Bake-out* | (Pirani) | Filament Temperature | |||
5 to 55 °C | –40 to +65 °C | 150 °C | 120 °C | ||||
Supply voltage | At gauge | Ripple | Power consumption | ||||
15 to 30 VDC | ≤1 Vpp | ≤2 W | |||||
Output signal (measurement signal) | Voltage range | Measurement range | |||||
0 to 10.5 V | 1.82 to 8.6 V | ||||||
Voltage vs. pressure | 0.6 V/decade, logarithmic | ||||||
Error signal | <0.5 V (no supply), >9.5 V (Pirani sensor, filament rupture) | ||||||
Minimum loaded impedance | 10 kΩ, short-circuit proof | ||||||
Response time | <10 ms (@ p> 10-6 mbar), ≈1000 ms (@ p= 10-8 mbar) | ||||||
Identification gauge | 85 kΩ, referenced to supply common | ||||||
Status | Pirani-only mode | Combined Pirani/cold cathode mode | LED | ||||
0 V (low) | 15 V to 30 (high) | LED green high voltage on | |||||
Electrical connection | FCC 68 appliance connector, 8 poles, female | ||||||
Sensor cable | 8 poles plus shielding | ||||||
Maximum cable length | ≤ 50 m | ||||||
Operating voltage/current | ≤3.3 kV/≤500 A | ||||||
Materials exposed to vacuum | SS, Al2O3, FPM75, Mo, Ni, Au, W | ||||||
Internal volume | ≈ 20 cm3 | ||||||
Weight | DN 25 ISO-KF ≈700g, DN 40 CF ≈980g | ||||||
Standards | EN 61000-6-2, EN 61000-6-3, EN 61010-1 |
Click Here for Agilent FRG 700 Manual
A&J Vacuum Services offers full repair/service of Agilent / Varian, along with all other brands offered on our website. AJVS also services Agilent / Varian pumps. Please contact us for information about our service and repair program or click http://www.ajvs.com/service.php to access our services page. We also offer emergency service upon request. For more information, please email A&J Vacuum Services at info@ajvs.com or call (973) 249-0854. Thank you for choosing AJVS as your supplier.
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.