Adixen Drytel 1025 Turbo Pumping Station, with MDP 5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710
Item#: PN21650 Mfr Part#: D025AQNNS710 Manufacturer: Adixen / Alcatel
Condition: Remanufactured In Stock
Remanufactured Adixen Drytel1025 Turbo Pumping Station, with MDP5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710, Alcatel 1025

Features:
  • Like New !!!
  • Reducing Adapter ISO63 to KF 25, and protection screen Included
  • Protective Inlet screen Included
  • Outlet Silencer Installed

PRICE: $12,950.00
WEB SAVINGS: $3,000.00
YOU PAY: $9,950.00
Item#: PN21650 Mfr Part#: D025AQNNS710
Adixen Drytel 1025 Turbo Pumping Station, with MDP 5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710
Item#: PN21650 Mfr Part#: D025AQNNS710 Manufacturer: Adixen / Alcatel

Fully Rebuilt Adixen Drytel 1025 Turbo Pumping Station, with MDP5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710, Also known as Alcatel Drytel 1025

Overview:

The Adixen Drytel 1025 series of products are dry pumping systems that include an Alcatel MDP 5011 or also known as Adixen MDP5011 Turbo molecular drag pump (MDP) or a hybrid turbo pump (AMH) and an oil-free forepump. Designed to be used on a bench top or easily integrated into a system, these units provide a dry, clean vacuum from atmosphere to 10-6 mbar (Torr).

Please note: System is curently set to U.S. 115 VAC, it can be changed to high 220 VAC.

Alcatel Drytel 1025 Station has a complete offer of tiny dry pumping groups for high vacuum applications.

The Drytel 1025 System Includes:

  • Alcatel MDP5011 Turbo Drag Pump
  • Alcatel AMD4 Diaphragm Dry Vacuum Pump

Please note: System does not include Venting valve or remote control connector. 

The two pumping stages working in series (MDP5011 and AMD 4 diaphragm pump) don’t require any lubricant to operate, permitting use on ultra-clean processes.

 

The Drytel 1025 Pumping Station series is the least expensive solution to achieve a clean vacuum down to 10-6 mbar.

The Drytel1025  series is recommended for all applications where a dry, clean vacuum is required, such as in industry:

  • Semiconductor
  • Analytical Instrumentation
  • Pharmaceutical
  • Chemical
  • Research and Development laboratories

Adixen 1025 Station can also be used in various other types of applications:

  • Backing of turbomolecular pumps
  • Loadlock pumping
  • Mass spectrometry
  • Surface analysis
  • Ion pump evacuation
  • Cryopump regeneration
  • Calibration
  • Gas industry
  • Gas lines

A&J Vacuum Services, Inc. AJVS Rrepair / Rebuild and Service Alcatel Drytel 1025 Turbo Pumping Stations, Drytel 30, Drytel 31, Drytel 100, Adixen Vacuum pumps, Alcatel Turbo Pumping Stations along with all other Adixen Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Fully Rebuilt Adixen Drytel 1025 Turbo Pumping Station, with MDP5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710, Also known as Alcatel Drytel 1025

Technical Data:

Pumping Speed (l/s):

  • N2: 7.5
  • He: 4
  • H2: 3

Please note: System is curently set to U.S. 115 VAC, it can be changed to high 220 VAC.

Please note: System does not include Venting valve or remote control connector. 

Ultimate Pressure (mbar) 10-6 mbar

Backing pump pumping rate: 1.2 m3/h

Maximum Inlet Pressure: 5 mbar

Mains Voltage: 100 / 115 / 200 / 230 / 240

Frequency: 50/60 Hz

Start-up Time (min): 2

Cooling System: Air

Maximum Ambient Temperature (°C): 0 to 40

Maximum Power Consumption (VA): <160

Standard Flange: 63 ISO-K

Outlet Silencer Installed

Noise Level: <56 dBA

Unit weight: 55 lbs

 

A&J Vacuum Services, Inc. AJVS Rrepair / Rebuild and Service Alcatel Drytel 1025 Turbo Pumping Stations, Drytel 30, Drytel 31, Drytel 100, Adixen Vacuum pumps, Alcatel Turbo Pumping Stations along with all other Adixen Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

 

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Adixen Drytel 1025 Turbo Pumping Station, with MDP 5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710
Item#: PN21650 Mfr Part#: D025AQNNS710 Manufacturer: Adixen / Alcatel

Fully Rebuilt Adixen Drytel 1025 Turbo Pumping Station, with MDP5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710, Also known as Alcatel Drytel 1025

Overview:

The Adixen Drytel 1025 series of products are dry pumping systems that include an Alcatel MDP 5011 or also known as Adixen MDP5011 Turbo molecular drag pump (MDP) or a hybrid turbo pump (AMH) and an oil-free forepump. Designed to be used on a bench top or easily integrated into a system, these units provide a dry, clean vacuum from atmosphere to 10-6 mbar (Torr).

Please note: System is curently set to U.S. 115 VAC, it can be changed to high 220 VAC.

Alcatel Drytel 1025 Station has a complete offer of tiny dry pumping groups for high vacuum applications.

The Drytel 1025 System Includes:

  • Alcatel MDP5011 Turbo Drag Pump
  • Alcatel AMD4 Diaphragm Dry Vacuum Pump

Please note: System does not include Venting valve or remote control connector. 

The two pumping stages working in series (MDP5011 and AMD 4 diaphragm pump) don’t require any lubricant to operate, permitting use on ultra-clean processes.

 

The Drytel 1025 Pumping Station series is the least expensive solution to achieve a clean vacuum down to 10-6 mbar.

The Drytel1025  series is recommended for all applications where a dry, clean vacuum is required, such as in industry:

  • Semiconductor
  • Analytical Instrumentation
  • Pharmaceutical
  • Chemical
  • Research and Development laboratories

Adixen 1025 Station can also be used in various other types of applications:

  • Backing of turbomolecular pumps
  • Loadlock pumping
  • Mass spectrometry
  • Surface analysis
  • Ion pump evacuation
  • Cryopump regeneration
  • Calibration
  • Gas industry
  • Gas lines

A&J Vacuum Services, Inc. AJVS Rrepair / Rebuild and Service Alcatel Drytel 1025 Turbo Pumping Stations, Drytel 30, Drytel 31, Drytel 100, Adixen Vacuum pumps, Alcatel Turbo Pumping Stations along with all other Adixen Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

Fully Rebuilt Adixen Drytel 1025 Turbo Pumping Station, with MDP5011 Turbo Pump and Adixen AMD-4 Dry Diaphragm Pump, 115/220 VAC Set to 115 VAC, D025AQNNS710, Also known as Alcatel Drytel 1025

Technical Data:

Pumping Speed (l/s):

  • N2: 7.5
  • He: 4
  • H2: 3

Please note: System is curently set to U.S. 115 VAC, it can be changed to high 220 VAC.

Please note: System does not include Venting valve or remote control connector. 

Ultimate Pressure (mbar) 10-6 mbar

Backing pump pumping rate: 1.2 m3/h

Maximum Inlet Pressure: 5 mbar

Mains Voltage: 100 / 115 / 200 / 230 / 240

Frequency: 50/60 Hz

Start-up Time (min): 2

Cooling System: Air

Maximum Ambient Temperature (°C): 0 to 40

Maximum Power Consumption (VA): <160

Standard Flange: 63 ISO-K

Outlet Silencer Installed

Noise Level: <56 dBA

Unit weight: 55 lbs

 

A&J Vacuum Services, Inc. AJVS Rrepair / Rebuild and Service Alcatel Drytel 1025 Turbo Pumping Stations, Drytel 30, Drytel 31, Drytel 100, Adixen Vacuum pumps, Alcatel Turbo Pumping Stations along with all other Adixen Turbo Pump Service and repair. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854

 

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.