Inlet Screen (Splinter Shield) for Alcatel Adixen ATP 80, MDP 5010 and MDP 5011 Turbo Pumps, DN 63 ISO-K, 063117
Item#: PN17485 Mfr Part#: 063117 Manufacturer: Adixen / Alcatel
Condition: New In Stock
New Inlet Screen 2.5 mm (Splinter Shield) for Alcatel Adixen ATP 80, MDP 5010 and MDP 5011, ATH 31 Turbo Vacuum Pumps, DN 63 ISO-K, 063117

Features:
  • P/N 063117

PRICE: $162.00
WEB SAVINGS: $37.00
YOU PAY: $125.00
Item#: PN17485 Mfr Part#: 063117
Inlet Screen (Splinter Shield) for Alcatel Adixen ATP 80, MDP 5010 and MDP 5011 Turbo Pumps, DN 63 ISO-K, 063117
Item#: PN17485 Mfr Part#: 063117 Manufacturer: Adixen / Alcatel

Inlet Screen (Splinter Shield) for Alcatel Adixen ATP 80, MDP 5010 and MDP 5011, ATH 31 Turbo Vacuum Pumps, DN 63 ISO-K, 063117


This filter protects the pump against solid particles 2.5 mm

Alcatel Adixen Splinter Shield (Inlet Screen) is designed to be used with the following turbo vacuum pumps:

  • Alcatel Adixen ATP 80
  • Alcatel MDP 5010
  • Alcatel MDP 5011
  • Alcatel ATH31

This filter protects the pump against solid particles 2.5 mm

Alcatel Adixen Splinter Shield P/N 063117 (Inlet Screen) is designed to be used with the following turbo vacuum pumps:

  • Alcatel Adixen ATP 80
  • Alcatel MDP 5010
  • Alcatel MDP 5011
  • Alcatel ATH31
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Inlet Screen (Splinter Shield) for Alcatel Adixen ATP 80, MDP 5010 and MDP 5011 Turbo Pumps, DN 63 ISO-K, 063117
Item#: PN17485 Mfr Part#: 063117 Manufacturer: Adixen / Alcatel

Inlet Screen (Splinter Shield) for Alcatel Adixen ATP 80, MDP 5010 and MDP 5011, ATH 31 Turbo Vacuum Pumps, DN 63 ISO-K, 063117


This filter protects the pump against solid particles 2.5 mm

Alcatel Adixen Splinter Shield (Inlet Screen) is designed to be used with the following turbo vacuum pumps:

  • Alcatel Adixen ATP 80
  • Alcatel MDP 5010
  • Alcatel MDP 5011
  • Alcatel ATH31

This filter protects the pump against solid particles 2.5 mm

Alcatel Adixen Splinter Shield P/N 063117 (Inlet Screen) is designed to be used with the following turbo vacuum pumps:

  • Alcatel Adixen ATP 80
  • Alcatel MDP 5010
  • Alcatel MDP 5011
  • Alcatel ATH31
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.