Leybold Turbotronik NT150/360 Turbo Pump Controller, 85572
Item#: PN00329 Mfr Part#: 85572 Manufacturer: Leybold
Condition: Remanufactured Call us for Availability
Remanufactured Leybold Turbotronik NT150 360 Turbo Pump Controller, 85572, This Leybold Heraeus TurboTronik NT 150/360 controller Compatibility: Leybold Heraeus Turbo Molecular Pumps TurboVac 150 TurboVac 360

Features:

Price upon request
Item#: PN00329 Mfr Part#: 85572
Leybold Turbotronik NT150/360 Turbo Pump Controller, 85572
Item#: PN00329 Mfr Part#: 85572 Manufacturer: Leybold

Overview:

The Leybold Turbotronik NT 150/360 solid-state frequency converter converts the single-phase A.C. voltage of the mains supply into a three-phase A.C. voltage with variable voltage and frequency.

The frequency converter is an externally controlled three-phase transistor-rectifier consisting mainly of six transistor switches. These transistor switches are controlled so that a three-phase connection is formed at the output R, S, T. The diodes connected in antiparallel to the connected consumer into the intermediate D.C. circuit.

After depressing the "START" button, the voltage Uzk in the D.C. intermediate circuit is controlled according to an IU characteristic. Current I and voltage Uzk are proportional to motor current Im and motor voltage Um. The frequency of the three-phase output voltage is varied from a preset minimum value, as a function of the D.C. intermediate circuit voltage Uzk, up to a preset maximum value.

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

This item is non-returnable/non-refundable

Technical Data:

Mains Supply (50/60 Hz): 100/120Vr.m.s.

Power Consumption:

  • During Acceleration (max. 30 mins.): 680 VA
  • For Continuous Duty: 480 VA
  • For Short Time (0.5 sec): 750 VA

Max. Output Voltage: 3 x 45 Vr.m.s.

Overload Current Limitation: 3.5 A

Rated Frequency:

  • TMP 150: 840 Hz
  • TMP 360: 760 Hz

Dimensions (W x H x D): 213 x 129 x 290 mm

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Leybold Turbotronik NT150/360 Turbo Pump Controller, 85572
Item#: PN00329 Mfr Part#: 85572 Manufacturer: Leybold

Overview:

The Leybold Turbotronik NT 150/360 solid-state frequency converter converts the single-phase A.C. voltage of the mains supply into a three-phase A.C. voltage with variable voltage and frequency.

The frequency converter is an externally controlled three-phase transistor-rectifier consisting mainly of six transistor switches. These transistor switches are controlled so that a three-phase connection is formed at the output R, S, T. The diodes connected in antiparallel to the connected consumer into the intermediate D.C. circuit.

After depressing the "START" button, the voltage Uzk in the D.C. intermediate circuit is controlled according to an IU characteristic. Current I and voltage Uzk are proportional to motor current Im and motor voltage Um. The frequency of the three-phase output voltage is varied from a preset minimum value, as a function of the D.C. intermediate circuit voltage Uzk, up to a preset maximum value.

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

Technical Data:

Mains Supply (50/60 Hz): 100/120Vr.m.s.

Power Consumption:

  • During Acceleration (max. 30 mins.): 680 VA
  • For Continuous Duty: 480 VA
  • For Short Time (0.5 sec): 750 VA

Max. Output Voltage: 3 x 45 Vr.m.s.

Overload Current Limitation: 3.5 A

Rated Frequency:

  • TMP 150: 840 Hz
  • TMP 360: 760 Hz

Dimensions (W x H x D): 213 x 129 x 290 mm

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.