This Pfeiffer TPU 510 Plasma Corrosive Turbo Pump has two ceramic bearings at each end to support rotor. The Turbo Pumps TPU 510 and TPH510 PMP01440 models are identical in terms of design.
This Pfeiffer TPU-510 Turbo Pump is lubricated with Pfeiffer TL 011 Turbo Pump fluid PM006034 AT / PN07244
Pfeiffer TPH 510 and TPU 510 only differ in their intake flange. TPH 510 comes with DN 160 ISO-K Inlet Flange, and TPU510 comes with DN-160 CF-F Conflat Inlet Flange.
Pfeiffer TPU 510 can have three different Inlet Flange orientations.
Pfieffer 510 Turbo Pump can be operated with one of the following Electronic Turbo Pump Controllers.
Those Pfeiffer Vacuum Turbo Pump Controllers are well design to be integrated into your High Vacuum System Vacuum, and can be rack mounted for easy panel access.
A&J Vacuum also repair / rebuild and service Pfeiffer TPU 510 C Plasma / PM P01 440 Turbo Pumps along with all other Pfeiffer Vacuum pumps and Pfeiffer Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
TPU 510 | ||
Intake flange | DN 160 CF-F | |
Fore-vacuum flange | DN 40 KF | |
Volume flow rate | ||
N2 | l/s | 500 |
He | l/s | 570 |
H2 | l/s | 500 |
Rec Backing Pump | 12 | |
Acc electronic drive unit | TCP 300 (TCP 300),TCP 310 (TCP 310),TCP 380 | |
Compression ratio | ||
N2 | 8x10^8 | |
He | 1.5x10^4 | |
H2 | 1x10^3 | |
Ultimate pressure | mbar | 10^-11 |
Ultimate operating | mbar | <1x10^-10 |
Pressure | mbar | <1x10^-9 |
3 | mbar | <1x10^-8 |
Speed | rpm | 60,000 |
Start-up time with TCP 300 (TCP 300)/310 | min | 6 |
Start-up time with TCP 120 (TCP 120)/121 | min | |
Permissible magnetic field | mT | 6 |
Oil filling | cm^3 | 2x10 |
Cooling water req | l/h | 15 |
Cooling water temperature | C | 5-25 |
Permissible ambient temperature for air cooing | C | 0-35 |
Power input of heater | Watt | 250 |
weight | kg | 30 |
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
This Pfeiffer TPU 510 Plasma Corrosive Turbo Pump has two ceramic bearings at each end to support rotor. The Turbo Pumps TPU 510 and TPH510 PMP01440 models are identical in terms of design.
This Pfeiffer TPU-510 Turbo Pump is lubricated with Pfeiffer TL 011 Turbo Pump fluid PM006034 AT / PN07244
Pfeiffer TPH 510 and TPU 510 only differ in their intake flange. TPH 510 comes with DN 160 ISO-K Inlet Flange, and TPU510 comes with DN-160 CF-F Conflat Inlet Flange.
Pfeiffer TPU 510 can have three different Inlet Flange orientations.
Pfieffer 510 Turbo Pump can be operated with one of the following Electronic Turbo Pump Controllers.
Those Pfeiffer Vacuum Turbo Pump Controllers are well design to be integrated into your High Vacuum System Vacuum, and can be rack mounted for easy panel access.
A&J Vacuum also repair / rebuild and service Pfeiffer TPU 510 C Plasma / PM P01 440 Turbo Pumps along with all other Pfeiffer Vacuum pumps and Pfeiffer Vacuum Rotary Vane pumps. Please contact us for information on service program or click here http://www.ajvs.com/service.php to go to our Service page. We also offer Emergency service upon request. For more information Please contact A&J Vacuum Services at 973-249-0854
TPU 510 | ||
Intake flange | DN 160 CF-F | |
Fore-vacuum flange | DN 40 KF | |
Volume flow rate | ||
N2 | l/s | 500 |
He | l/s | 570 |
H2 | l/s | 500 |
Rec Backing Pump | 12 | |
Acc electronic drive unit | TCP 300 (TCP 300),TCP 310 (TCP 310),TCP 380 | |
Compression ratio | ||
N2 | 8x10^8 | |
He | 1.5x10^4 | |
H2 | 1x10^3 | |
Ultimate pressure | mbar | 10^-11 |
Ultimate operating | mbar | <1x10^-10 |
Pressure | mbar | <1x10^-9 |
3 | mbar | <1x10^-8 |
Speed | rpm | 60,000 |
Start-up time with TCP 300 (TCP 300)/310 | min | 6 |
Start-up time with TCP 120 (TCP 120)/121 | min | |
Permissible magnetic field | mT | 6 |
Oil filling | cm^3 | 2x10 |
Cooling water req | l/h | 15 |
Cooling water temperature | C | 5-25 |
Permissible ambient temperature for air cooing | C | 0-35 |
Power input of heater | Watt | 250 |
weight | kg | 30 |
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.