phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
Agilent Varian V 250 C.U. Turbo Pump Controller Exchange Unit, 9699523
Item#: PN18446 Mfr Part#: 9699523 Manufacturer: Agilent Technologies / Varian
Condition: Demo Out of Stock
Demo Agilent Technologies / Varian V 250 C.U. Turbo Pump Controller Exchange Unit, 9699523

Features:

PRICE: $1,925.00
WEB SAVINGS: $202.00
YOU PAY: $1,723.00
Item#: PN18446 Mfr Part#: 9699523
Agilent Varian V 250 C.U. Turbo Pump Controller Exchange Unit, 9699523
Item#: PN18446 Mfr Part#: 9699523 Manufacturer: Agilent Technologies / Varian

Overview:

The models 969-9423 and 969-9523 are provided with a front panel with an LCD alphanumeric display to indicate the operating conditions/parameters of the Turbo-V pump and a keyboard, and a rear panel with input/output connectors. The model 969-9425 has the right panel with pump connector and hand held terminal connector, and the left panel with input/output connector, mains socket, forepump and vent coil output and fan connector. The following figure is a picture of the Turbo-V controllers. The controller is a solid-state frequency converter which is driven by a single chip microcomputer and is composed of:

  • Power transformer
  • PCB including: power supply and 3-phase output, analog and input/output section, microprocessor and digital section, display and keyboard circuits.

The power supply converts the single phase (50-60 Hz) AC mains supply into a 3-phase, low voltage, medium frequency output which is required to power the Turbo-V pump. The microcomputer generates the variable output frequency and controls the 3-phase output voltage according to the software and the gas load condition of the pump. Moreover, it manages signals from sensors, input/output connection information to be displayed, and gives outputs for a fully automatic operation. A dedicated non-volatile RAM is used to store pump operating parameters and the input/output programmed information upon failure for a period of 10 years accumulated off time.

  • The controller can be operated via:
  • Front panel (or the optional hand held terminal) switches
  • Remote signals via input/output connector
  • RS 232 serial link (option).

Technical Specifications:

Input:
Voltage
Frequency
Power
100, 120, 220, 240
Vac ±10%, 1-phase
47 to 63 Hz
450 VA maximum
Output:
Voltage
Frequency
Powe
54 Vac nominal ±10%,
3-phase
933 Hz, ±2%
150 W maximum
Operating temperature 0 °C to °
Storage temperature -20 °C to °
Fuse (mains) 2 x T3A (slow blow)
disregarding the main
P1 optically insulated
input

J2 optically insulated
output
Minimum ON 3 mA
Maximum 5 mA

24 Vdc, 60 m
P6 output fan 100 mA
J7 output (forepump
coil, etc.)
120 Vac, 1A
disregarding the mains
Radio interference
suppression
EN 55011 class A group 1
IEC1000-4-2,
1000-4-3, 1000-4-4
Safety standard EN 61010-1
Weight:
Model 969-9423
and 969-9523
Model 969-9425
4.5 Kg (10 lbs)
4 Kg (8 lbs)

 

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

This item is non-returnable/non-refundable
| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Agilent Varian V 250 C.U. Turbo Pump Controller Exchange Unit, 9699523
Item#: PN18446 Mfr Part#: 9699523 Manufacturer: Agilent Technologies / Varian

Overview:

The models 969-9423 and 969-9523 are provided with a front panel with an LCD alphanumeric display to indicate the operating conditions/parameters of the Turbo-V pump and a keyboard, and a rear panel with input/output connectors. The model 969-9425 has the right panel with pump connector and hand held terminal connector, and the left panel with input/output connector, mains socket, forepump and vent coil output and fan connector. The following figure is a picture of the Turbo-V controllers. The controller is a solid-state frequency converter which is driven by a single chip microcomputer and is composed of:

  • Power transformer
  • PCB including: power supply and 3-phase output, analog and input/output section, microprocessor and digital section, display and keyboard circuits.

The power supply converts the single phase (50-60 Hz) AC mains supply into a 3-phase, low voltage, medium frequency output which is required to power the Turbo-V pump. The microcomputer generates the variable output frequency and controls the 3-phase output voltage according to the software and the gas load condition of the pump. Moreover, it manages signals from sensors, input/output connection information to be displayed, and gives outputs for a fully automatic operation. A dedicated non-volatile RAM is used to store pump operating parameters and the input/output programmed information upon failure for a period of 10 years accumulated off time.

  • The controller can be operated via:
  • Front panel (or the optional hand held terminal) switches
  • Remote signals via input/output connector
  • RS 232 serial link (option).

Technical Specifications:

Input:
Voltage
Frequency
Power
100, 120, 220, 240
Vac ±10%, 1-phase
47 to 63 Hz
450 VA maximum
Output:
Voltage
Frequency
Powe
54 Vac nominal ±10%,
3-phase
933 Hz, ±2%
150 W maximum
Operating temperature 0 °C to °
Storage temperature -20 °C to °
Fuse (mains) 2 x T3A (slow blow)
disregarding the main
P1 optically insulated
input

J2 optically insulated
output
Minimum ON 3 mA
Maximum 5 mA

24 Vdc, 60 m
P6 output fan 100 mA
J7 output (forepump
coil, etc.)
120 Vac, 1A
disregarding the mains
Radio interference
suppression
EN 55011 class A group 1
IEC1000-4-2,
1000-4-3, 1000-4-4
Safety standard EN 61010-1
Weight:
Model 969-9423
and 969-9523
Model 969-9425
4.5 Kg (10 lbs)
4 Kg (8 lbs)

 

THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.