phone icon
Sales and Service
855 882 2886
basket icon
0 Items
$0.00
Find us on:
- Agilent Technologies / Varian
- Stokes Vacuum
- AJVS
- Thread Sealants
- Mounting Kits
- Leak Detectors
- Shipping Crates
- Cooling Water Circulators
- Laboratory Pipette Washers
- Laboratory Stirrers
- Muffle Furnace
- Rotary Evaporators
- Cold Traps
ULVAC TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284
Item#: PN22250 Mfr Part#: 1013284 Manufacturer: Ulvac
Condition: New
New Ulvac TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284

Features:
  • PN 1013284
  • Oil Mist Trap
  • for PKS-016 Rotary Piston Pump
  • OEM

PRICE: $1,975.00
WEB SAVINGS: $125.00
YOU PAY: $1,850.00
Item#: PN22250 Mfr Part#: 1013284
ULVAC TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284
Item#: PN22250 Mfr Part#: 1013284 Manufacturer: Ulvac

ULVAC TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284


ULVAC TM-3

When an oil rotary pump is started at atmospheric pressure, and operated during low vacuum operation, the pump oil is exhausted along with the exhaust gas that is being pumped. This oil-laden exhaust mist, which consists of tiny oil droplets, appears as "smoke" exiting from the exhaust port of the pump. The TM and TMX series oil mist traps help to ensure a clean working environment and protect indoor equipment from contamination that would otherwise be caused by this oil mist.
 
Features
  • Removes oil droplets (“smoke”)
    Pump oil vapor is greatly reduced reducing contamination in addition the need to regularly replenish the pump oil is likewise greatly reduced.

  • Noise is most effectively reduced when the pump starts from atmospheric pressure, during low vacuum pumping, and during gas ballast operations. Low frequency noise is particularly reduced.

  • Selectable oil recovery method (optional)
    When trapped oil is returned directly to the main pumping unit and reused, the filter lifespan is decreased and pump problems may occur.
    Since recovery of the trapped oil is dependent on pump operating conditions, please consult Ulvac for advice about your particular pumping task and to help ensure the correct match of components for your application.

  • Since the connection ports of TM series units are made to match standard pump exhaust ports, attachment is simple. (Excluding VD601 and VD901)

  • The internal filter element is a replaceable cartridge
    Replacing this filter cartridge is simple. (An adapter is required when changing filters of old TM-3, 4, and 4S models to cartridge filters)

*1 Be sure to use an oil mist trap that is appropriately sized to match the pumping speed of the pump and the volume of the chamber which is being evacuated.
*2 An adapter is required for attachment to PVD series, VD151 and VD201.
*3 Oil recovery cannot be used with TMX-1 and TMX-2 models.
*4 Conversion to a cartridge filter is not possible for TMX-1, TMX-2, and TM-2 (old model) units.

This item is non-returnable/non-refundable

ULVAC TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284

Specifications

Model Attachment flange *1 Vacuum pump used Weight(kg) Material
TMX-1 Special flange/
G1 1/2

PVD-180(B) *2

PVD-360(B)

VD151

VD201

1.1 Trap : Mild steel (SPCC)
Filter : Glass wool
TM201 VF40/G 1・1/2 VD301 (for low loads)*5
VD401 (for low loads)
8.5
TM401 VF40/G 1・1/2 VD301 (for high loads) *6
VD401 (for high loads)
VD601 (for low loads)
VD901 (for low loads)
10
TM-2
(standard, F) *3
VG50/G2, VG50
(for PKS-016)
VF40/G2, VG50
(for VD601/VD901)
PKS-016
VD601 (for high loads)*2
VD901 (for high loads)
5.7(6.2) *4
TM-3
(standard, F)

 

VG80/G3, VG80
(for PKS-030)
VF50\G3, VG80
(for VS1501)
PKS-030
VS1501
10(11.5)*4
TM-4
(standard, F)
VG100/G4, VG100
8for PKS-070)
VF50/G4, VG100
(for VS2401)
PKS-070
VS2401
23.5(25)*4
TM-4S VG100/VG100
(for PKS-070)
VF50/VG100
(for VS2401)
PKS-070 (for high loads)
VS2401 (for high loads)
59

*1 Pump attachment flange : JIS B2290 vacuum flange (except for special flanges)/vent pipe screw size
*2 Adapter is required when attaching to PVD-180(B), PVD-360(B), VD151, VD201, VD601, and VD901.
*3 Standard : Umbrella type; F : Flange type.
*4 Values in ( ) indicate mass with flange attached.
*5 Low load models should have a cntinuous suction Pressure.
*6 Hgh load models should have a continuous suction pressure of 100kPa or less.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

ULVAC TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284
Item#: PN22250 Mfr Part#: 1013284 Manufacturer: Ulvac

ULVAC TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284


ULVAC TM-3

When an oil rotary pump is started at atmospheric pressure, and operated during low vacuum operation, the pump oil is exhausted along with the exhaust gas that is being pumped. This oil-laden exhaust mist, which consists of tiny oil droplets, appears as "smoke" exiting from the exhaust port of the pump. The TM and TMX series oil mist traps help to ensure a clean working environment and protect indoor equipment from contamination that would otherwise be caused by this oil mist.
 
Features
  • Removes oil droplets (“smoke”)
    Pump oil vapor is greatly reduced reducing contamination in addition the need to regularly replenish the pump oil is likewise greatly reduced.

  • Noise is most effectively reduced when the pump starts from atmospheric pressure, during low vacuum pumping, and during gas ballast operations. Low frequency noise is particularly reduced.

  • Selectable oil recovery method (optional)
    When trapped oil is returned directly to the main pumping unit and reused, the filter lifespan is decreased and pump problems may occur.
    Since recovery of the trapped oil is dependent on pump operating conditions, please consult Ulvac for advice about your particular pumping task and to help ensure the correct match of components for your application.

  • Since the connection ports of TM series units are made to match standard pump exhaust ports, attachment is simple. (Excluding VD601 and VD901)

  • The internal filter element is a replaceable cartridge
    Replacing this filter cartridge is simple. (An adapter is required when changing filters of old TM-3, 4, and 4S models to cartridge filters)

*1 Be sure to use an oil mist trap that is appropriately sized to match the pumping speed of the pump and the volume of the chamber which is being evacuated.
*2 An adapter is required for attachment to PVD series, VD151 and VD201.
*3 Oil recovery cannot be used with TMX-1 and TMX-2 models.
*4 Conversion to a cartridge filter is not possible for TMX-1, TMX-2, and TM-2 (old model) units.

ULVAC TM-2 (F) Oil Mist Trap for PKS-016 Series Rotary Piston Pumps, 1013284

Specifications

Model Attachment flange *1 Vacuum pump used Weight(kg) Material
TMX-1 Special flange/
G1 1/2

PVD-180(B) *2

PVD-360(B)

VD151

VD201

1.1 Trap : Mild steel (SPCC)
Filter : Glass wool
TM201 VF40/G 1・1/2 VD301 (for low loads)*5
VD401 (for low loads)
8.5
TM401 VF40/G 1・1/2 VD301 (for high loads) *6
VD401 (for high loads)
VD601 (for low loads)
VD901 (for low loads)
10
TM-2
(standard, F) *3
VG50/G2, VG50
(for PKS-016)
VF40/G2, VG50
(for VD601/VD901)
PKS-016
VD601 (for high loads)*2
VD901 (for high loads)
5.7(6.2) *4
TM-3
(standard, F)

 

VG80/G3, VG80
(for PKS-030)
VF50\G3, VG80
(for VS1501)
PKS-030
VS1501
10(11.5)*4
TM-4
(standard, F)
VG100/G4, VG100
8for PKS-070)
VF50/G4, VG100
(for VS2401)
PKS-070
VS2401
23.5(25)*4
TM-4S VG100/VG100
(for PKS-070)
VF50/VG100
(for VS2401)
PKS-070 (for high loads)
VS2401 (for high loads)
59

*1 Pump attachment flange : JIS B2290 vacuum flange (except for special flanges)/vent pipe screw size
*2 Adapter is required when attaching to PVD-180(B), PVD-360(B), VD151, VD201, VD601, and VD901.
*3 Standard : Umbrella type; F : Flange type.
*4 Values in ( ) indicate mass with flange attached.
*5 Low load models should have a cntinuous suction Pressure.
*6 Hgh load models should have a continuous suction pressure of 100kPa or less.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.