Pfeiffer Vacuum PCR 280 Spare measurement system replacement PT120041T / PT 120 041-T
Item#: PN24443 Mfr Part#: PT120041T / PT 120 041-T Manufacturer: Pfeiffer Vacuum
Condition: New
New Spare measurement system for Pfeiffer PCR 280 PT120041T / PT 120 041-T

Features:
  • Wide Measurement Range of 5 * 10^[-5] to 1.5 * 10^3 hPa
  • Bakeout Remperature: 80 °C
  • PT120041T / PT 120 041-T
  • Spare measurement system replacement

PRICE: $670.00
WEB SAVINGS: $80.00
YOU PAY: $590.00
Item#: PN24443 Mfr Part#: PT120041T / PT 120 041-T
Pfeiffer Vacuum PCR 280 Spare measurement system replacement PT120041T / PT 120 041-T
Item#: PN24443 Mfr Part#: PT120041T / PT 120 041-T Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum PCR 280 Spare measurement system replacement PT120041T / PT 120 041-T

 

Product Features - Pfeiffer Vacuum Pirani / Capcitance PCR280 Gauge (w/ DN 16 Flange):


  • Utilized for Accurate Gas-Type Independent Pressure Measurement of Venting Procedures
  • Display Range: 5 * 10^[-5] to 1500 hPa
  • Two Sensors / Modes of Measurement in One Gauge Head (Pirani and Capacitance Diaphragm)
  • Metal-Sealed Upon Arrival
  • Bakeout Remperature: 80 °C
  • Output Signal: 1.2 – 8.68 V Logarithm of Pressure
  • Voltage supply: 15 – 30 V DC
This item is non-returnable/non-refundable

Pfeiffer Vacuum PCR 280 Spare measurement system replacement PT120041T / PT 120 041-T

Technical Data:


Accuracy (1) 1 * 10^[-3] – 100 hPa ± 15 %
Accuracy (1) 100 – 950 hPa ± 5 %
Accuracy (2) 5 * 10^[-4] – 1 * 10^[-3] hPa ± 50 %
Accuracy (2) 950 – 1050 hPa ± 2.5 %
Ambient Temperature 10-50 °C | 50-122 °F | 283-323 K
Bakeout Temperature 80 °C
Feature (Material) Stainless Steel, Metal Sealed
Feedthrough Glass
Filament Tungsten
Flange Material Stainless Steel
Measurement Range 5 * 10^[-5] – 1.5 * 10^3 hPa
Nominal Diameter / Flange Model DN 16 ISO-KF
Output Signal: Measurement Range 1.2–8.68 V  
Output Signal: Minimum Load 10 kΩ
Pressure (Maximum) 5,000 hPa | 3,750 Torr | 5,000 mbar
Repeatability: 1 * 10^[-3] – 1100 hPa ± 2 %
Seal Metal
Sensor cable length min. 100 m
Supply: Power Consumption Max. 2.5 W
Supply: Voltage V DC 15 – 30 V DC
Temperature: Storage -20-65 °C | -4-149 °F | 253-338 K
Volume 8 cm³
Weight 120 g

A&J Vacuum services and repairs Pfeiffer Vacuum PCR 280 Series Dual Pirani/Capacitance Gauges, along with all other Pfeiffer Vacuum pressure gauges, transmitters, and measurement devices available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier​.

| Service and Repair
We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.

Overview

Pfeiffer Vacuum PCR 280 Spare measurement system replacement PT120041T / PT 120 041-T
Item#: PN24443 Mfr Part#: PT120041T / PT 120 041-T Manufacturer: Pfeiffer Vacuum

Pfeiffer Vacuum PCR 280 Spare measurement system replacement PT120041T / PT 120 041-T

 

Product Features - Pfeiffer Vacuum Pirani / Capcitance PCR280 Gauge (w/ DN 16 Flange):


  • Utilized for Accurate Gas-Type Independent Pressure Measurement of Venting Procedures
  • Display Range: 5 * 10^[-5] to 1500 hPa
  • Two Sensors / Modes of Measurement in One Gauge Head (Pirani and Capacitance Diaphragm)
  • Metal-Sealed Upon Arrival
  • Bakeout Remperature: 80 °C
  • Output Signal: 1.2 – 8.68 V Logarithm of Pressure
  • Voltage supply: 15 – 30 V DC

Pfeiffer Vacuum PCR 280 Spare measurement system replacement PT120041T / PT 120 041-T

Technical Data:


Accuracy (1) 1 * 10^[-3] – 100 hPa ± 15 %
Accuracy (1) 100 – 950 hPa ± 5 %
Accuracy (2) 5 * 10^[-4] – 1 * 10^[-3] hPa ± 50 %
Accuracy (2) 950 – 1050 hPa ± 2.5 %
Ambient Temperature 10-50 °C | 50-122 °F | 283-323 K
Bakeout Temperature 80 °C
Feature (Material) Stainless Steel, Metal Sealed
Feedthrough Glass
Filament Tungsten
Flange Material Stainless Steel
Measurement Range 5 * 10^[-5] – 1.5 * 10^3 hPa
Nominal Diameter / Flange Model DN 16 ISO-KF
Output Signal: Measurement Range 1.2–8.68 V  
Output Signal: Minimum Load 10 kΩ
Pressure (Maximum) 5,000 hPa | 3,750 Torr | 5,000 mbar
Repeatability: 1 * 10^[-3] – 1100 hPa ± 2 %
Seal Metal
Sensor cable length min. 100 m
Supply: Power Consumption Max. 2.5 W
Supply: Voltage V DC 15 – 30 V DC
Temperature: Storage -20-65 °C | -4-149 °F | 253-338 K
Volume 8 cm³
Weight 120 g

A&J Vacuum services and repairs Pfeiffer Vacuum PCR 280 Series Dual Pirani/Capacitance Gauges, along with all other Pfeiffer Vacuum pressure gauges, transmitters, and measurement devices available on our website. Please contact us for additional information concerning our service program or click http://www.ajvs.com/service.php to access our Services page. We likewise offer emergency service and repair upon request. For more information, please contact A&J Vacuum Services at (973) 249-0854. Thank you for choosing AJVS as your supplier​.

We can repair your:
  • Turbo Pumps
  • Rotary Vane Pumps
  • Dry Vacuum Pumps
  • Leak Detectors
  • Scroll Dry Pumps
  • Vacuum Boosters
  • Diaphragm Dry Pumps
You trusted worldwide leader of High Vacuum equipment!
Call us for your free repair estimate!
973-249-0854

A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.

We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.

We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.

Repair Steps

  1. Full incoming inspection and run up time check, vibration check, drive inspection.
  2. Full disassembly, decontamination and cleaning.
  3. Pump is balanced utilizing state-of-the-art equipment from the world leader in equipment balancing and analysis to reduce noise and vibrations and extend bearings life.
  4. Assembly and replacement of all necessary parts such as shafts, bushings, bearings, sleeves, O-rings, gaskets, seals, wicks, etc. Only parts that meet or surpass OEM specifications are used to ensure dependable highest quality service and long pump life.
  5. Final test and leak check. The pump in fully assembled condition is checked for vacuum seal. Leak test to 1 x 10-9 Mbar l/s. Vibrations are analyzed and test data is digitally recorded.

Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.


Contact
address
A&J Vacuum Services
16 Somerset Place, Clifton, NJ 07012
customer service
Customer Service
Phone: 973-249-0854, Fax: 973-249-0855
working hours
Service Hours
8:00am to 5:00pm, Monday thru Friday EST
All trademarks, trade names or logons mentioned or used are the property of their respective owners.