Pressure Measuring System, TPG 262 Dual Gauge controller combined with one (1) TPR 280 (KF-16) compact pirani gauge and one (1) PKR 251 (KF-25) compact cold cathode gauge and two 3 meter cables for measurement from 1000 to 2x10-mbar with 2 relays, 90-250V, 50-60 Hz.
*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*
Accuracy: 1 * 10^(-3) to 100 hPa | ± 15 % |
Ambient Temperature | 5-60 °C | 41-140 °F | 278-333 K |
Bakeout Temperature at Flange | 80 °C | 176 °F | 353 K |
Feature | Stainless Steel, Metal Sealed |
Feedthrough | Glass |
Filament | Tungsten |
Flange Material | Stainless Steel |
Measurement Range | 5 · 10-4 – 1 · 103 hPa |
Nominal Diameter | DN 16 ISO-KF |
Output Signal: Measurement Range | 2.2–8.5 V |
Output Signal: Minimum Load | 10 kΩ |
Pressure - Maximum: | 10,000 hPa | 7,500 Torr | 10,000 mbar |
Protection Category | IP40 |
Repeatability: 1 * 10^(-3) to 100 hPa | ± 2 % |
Resolution | 1 % of Reading |
Response Time | 80 ms |
Seal | Metal |
Sensor Cable Length (min.) | 200 m |
Supply: Power Consumption (max.) | ≤ 1 W |
Supply: Voltage V DC | 14 – 30 V DC |
Temperature: Storage | -20-65 °C | -4-149 °F | 253-338 K |
Volume | 1.5 cm³ |
Weight | 80 g |
Accuracy: 10-8 - 102 mbar | ± 30 % |
Bakeout temperature | 150 °C, electronic removed |
Feature | Interior FPM sealed |
Feedthrough | Al2O3, Glass |
Filament | Tungsten |
Filament | Molybdenum |
Flange | Stainless steel |
Flange (in) | DN 25 ISO-KF |
Measurement range max. | 1000 mbar |
Measurement range min. | 5 · 10-9 mbar |
Output signal: Minimum load | 10 kΩ |
Output signal: Pressure range | 1.8 - 8.6 V |
Output signal: Sensor error above | 9.5 V |
Output signal: Sensor error below | 0.5 V |
Pressure max. | 10 bar |
Repeatability: 10-8 - 102 mbar | ± 5 % |
Seal | FPM |
Sensor cable length | 300 m |
Supply: Power consumption max. | 2 W |
Supply: Voltage | 15-30 V DC |
Temperature: Operating | 5-55 °C |
Temperature: Storage | -40- °C |
Volume | 20 cm3 |
Weight | 700 g |
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.
Pressure Measuring System, TPG 262 Dual Gauge controller combined with one (1) TPR 280 (KF-16) compact pirani gauge and one (1) PKR 251 (KF-25) compact cold cathode gauge and two 3 meter cables for measurement from 1000 to 2x10-mbar with 2 relays, 90-250V, 50-60 Hz.
*THERE ARE NO RETURNS ON THIS PRODUCT IF PRODUCT IS OPENED OR USED*
Accuracy: 1 * 10^(-3) to 100 hPa | ± 15 % |
Ambient Temperature | 5-60 °C | 41-140 °F | 278-333 K |
Bakeout Temperature at Flange | 80 °C | 176 °F | 353 K |
Feature | Stainless Steel, Metal Sealed |
Feedthrough | Glass |
Filament | Tungsten |
Flange Material | Stainless Steel |
Measurement Range | 5 · 10-4 – 1 · 103 hPa |
Nominal Diameter | DN 16 ISO-KF |
Output Signal: Measurement Range | 2.2–8.5 V |
Output Signal: Minimum Load | 10 kΩ |
Pressure - Maximum: | 10,000 hPa | 7,500 Torr | 10,000 mbar |
Protection Category | IP40 |
Repeatability: 1 * 10^(-3) to 100 hPa | ± 2 % |
Resolution | 1 % of Reading |
Response Time | 80 ms |
Seal | Metal |
Sensor Cable Length (min.) | 200 m |
Supply: Power Consumption (max.) | ≤ 1 W |
Supply: Voltage V DC | 14 – 30 V DC |
Temperature: Storage | -20-65 °C | -4-149 °F | 253-338 K |
Volume | 1.5 cm³ |
Weight | 80 g |
Accuracy: 10-8 - 102 mbar | ± 30 % |
Bakeout temperature | 150 °C, electronic removed |
Feature | Interior FPM sealed |
Feedthrough | Al2O3, Glass |
Filament | Tungsten |
Filament | Molybdenum |
Flange | Stainless steel |
Flange (in) | DN 25 ISO-KF |
Measurement range max. | 1000 mbar |
Measurement range min. | 5 · 10-9 mbar |
Output signal: Minimum load | 10 kΩ |
Output signal: Pressure range | 1.8 - 8.6 V |
Output signal: Sensor error above | 9.5 V |
Output signal: Sensor error below | 0.5 V |
Pressure max. | 10 bar |
Repeatability: 10-8 - 102 mbar | ± 5 % |
Seal | FPM |
Sensor cable length | 300 m |
Supply: Power consumption max. | 2 W |
Supply: Voltage | 15-30 V DC |
Temperature: Operating | 5-55 °C |
Temperature: Storage | -40- °C |
Volume | 20 cm3 |
Weight | 700 g |
A & J Vacuum Services provides repair service for all types of High Vacuum equipment. We perform Turbomolecular Pump repair, Turbo Pump Repair, Dry Pump repair, Vacuum Pump repair, Mass Spectrometer repair, Rotary Vane Pump repair, Vacuum Booster repair, and Leak detector repair. Our highly trained technicians have years of experience and guarantee the highest quality service.
We operate at our own full service repair facility in Clifton, NJ. We have invested in state-of-the-art equipment including; complete line of decontamination, cleaning, drying, balancing, vibration analysis and software to minimize failures. Our in-house machine shop is capable of machining various components, prototypes and housing conversions as needed.
We support all major manufacturers including Pfeiffer Vacuum, Alcatel / Adixen, Edwards Vacuum, Varian, Oerlikon / Leybod Vacuum, Vacuubrand, and Agilent Technologies.
Repair Steps
Every pump and instrument is extensively tested for 48 hours. During our final tests, we monitor total pressure, temperature, vibration and noise level utilizing newest testing technologies and techniques specified by OEM. Upon request, we can provide our customers with a pump down graph. Call us for your free repair estimate at 1-973-249-0854.